China Bathroom EVI 30HP Spa Heat Pump Split 106.5KW 4.5 COP
China Bathroom EVI 30HP Spa Heat Pump Split 106.5KW 4.5 COP

  1. China Bathroom EVI 30HP Spa Heat Pump Split 106.5KW 4.5 COP

Bathroom EVI 30HP Spa Heat Pump Split 106.5KW 4.5 COP

  1. MOQ: Negotiable
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 80000pcs/year
Delivery Time 1-30 working days
Packaging Details standard export package, or as per customer request
Specificaition DKFXRS-19II/CY/ air source heat pump water heater
Power 220V~240V/50Hz/1ph 380V~415V/50Hz/3ph
Condenser High efficiency shell and tube heat exchanger
Function Cooling,Heating,hot water,heating/hot water,DHW
Refrigerant R410A,R407C/R410A,R22/R407C,R143a,R407c
Compressor type Copeland EVI compressor
Brand Name LN
Model Number DKFXRS-38II/CY
Certification CE ISO CCC
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 80000pcs/year
Delivery Time 1-30 working days Packaging Details standard export package, or as per customer request
Specificaition DKFXRS-19II/CY/ air source heat pump water heater Power 220V~240V/50Hz/1ph 380V~415V/50Hz/3ph
Condenser High efficiency shell and tube heat exchanger Function Cooling,Heating,hot water,heating/hot water,DHW
Refrigerant R410A,R407C/R410A,R22/R407C,R143a,R407c Compressor type Copeland EVI compressor
Brand Name LN Model Number DKFXRS-38II/CY
Certification CE ISO CCC Place of Origin China
High Light 220V R744 Spa Heat Pump4.5 COP Spa Heat Pump106.5KW Spa Heat Pump

Features of 30HP 106.5 KW Split Heat Pump For Big Hot Water Requirement

The split heat pump shower room made of this heat pump includes a waste water recovery base, a shower room body arranged above the waste water recovery base, a hot water tank arranged outside the shower room body, and a heat pump system. The heat pump system includes a waste water recovery base. The heat pump evaporator in the recovery base, the heat pump condenser arranged in the hot water tank, the compressor connected to the condenser and the heat pump evaporator, the refrigerant throttling device connected to the heat pump evaporator, and the refrigerant throttling The refrigerant filter connected to the device is connected with the heat pump condenser; the compressor is installed on the outside of the shower room body, which reflects the high safety of the utility model.

For further specification of Inverter 30HP 106.5 KW Split Heat Pump For Big Hot Water Requirement Use and other specifications, welcome to contact us!

Unit type SJKRS-106 IC
Specifications 30HP
Power supply Three-phase five-wire380V/50Hz
Heating mode Direct heat/cycle type
Standard working condition Heating capacity( kw ) 106.5
Input Power(kW) 23.6
COP 4.5
Hot Water flow(m³/h) 2.29
High temperature condition Heating capacity kw ) 89
Input Power(kW) 27.8
COP 3.2
Hot Water flow(m³/h) 1.02
Low temperature condition Heating capacity( kw ) 62.2
Input Power(kW) 22.2
COP 2.8
Hot Water flow(m³/h) 1.16
Component Information Size of water pipe joint DN32
Water heat exchanger Plate or sleeve heat exchanger
Air Heat Exchanger Aluminum Fin for copper tube
compressor type Semi-closed reciprocating
Operation Panel Color touch screen
Maximum outlet temperature(℃) 90℃
Refrigerants R744 (CO2 )
Design pressure(MPa) High side 15, low side 8
Dimensions (length, width and height mm) 2670x1410x2150
Noise (dB) 70
Weight(kg) 1180
SCOPE of use Feed water temperature(℃) 5~ 40
Feed water pressure 0.05~ 0.4
Effluent temperature(℃) 55~ 90
Maximum flow 4.9
Ambient temperature(℃) ’-20~43

3) low temperature working condition: ambient temperature DB-10 °C, using side initial water temperature 9 °C, termination water temperature 55 °c;2) high temperature effluent: Ambient Temperature DB 20 ° c/WB 15 ° C, using side initial water temperature 15 ° C, termination water temperature 90 ° c;
1) standard working conditions: ambient temperature DB 20 ° c/WB 15 ° C, using side initial water temperature 15 ° C, termination water temperature 55 ° c;

Some projects for 30HP 106.5 KW Split Heat Pump For Big Hot Water Requirement

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company,Seller

  • Year Established:

    2002

  • Total Annual:

    1.MILLION-2MILLION

  • Employee Number:

    50~150

  • Ecer Certification:

    Active Member

As one of the most well-known and respected brands in the ASHP market, our heat pumps are suitable for small retail outlets and commercial buildings as well as domestic properties. Using efficient heat pump technology to deliver supreme comfort and low operating costs, we have different series ... As one of the most well-known and respected brands in the ASHP market, our heat pumps are suitable for small retail outlets and commercial buildings as well as domestic properties. Using efficient heat pump technology to deliver supreme comfort and low operating costs, we have different series ...

+ Read More

Get in touch with us

  • Reach Us
  • Maanshan Ruika Metal Products Technology Co., Ltd.
  • PO1669, Maanshan, Anhui Province, China
  • MsKelly
  • 15215554137
  • https://www.air-sourceheatingpump.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement