Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Packaging Details | Wooden case |
Type | Blood Testing Equipments |
Name | Class II A2 Biosafety Cabinets |
Model | BSC-1300A2 |
Overall size | 1500×800×2120mm |
Purification area size | 1300×700×600mm |
Product name | Biosafety cabinet |
Inside of the door | 0.38±0.025m/s |
Front inflow air | 0.48±0.025m/s |
Brand Name | HAIYING |
Model Number | BSC-1300A2 |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Animal Laboratories Class II Type A2 Biosafety Cabinet LED Panel
Cytotoxic Class II A2 Biosafety Cabinets 0.12um ULPA Filter
0.38mps Biological Safety Cabinet Class 2 LCD display
3um Class II A2 Biosafety Cabinets 304 Stainless Steel
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Packaging Details | Wooden case |
Type | Blood Testing Equipments | Name | Class II A2 Biosafety Cabinets |
Model | BSC-1300A2 | Overall size | 1500×800×2120mm |
Purification area size | 1300×700×600mm | Product name | Biosafety cabinet |
Inside of the door | 0.38±0.025m/s | Front inflow air | 0.48±0.025m/s |
Brand Name | HAIYING | Model Number | BSC-1300A2 |
Certification | CE | Place of Origin | CHINA |
High Light | CE hepa filter biological safety cabinet ,800MM biological safety cabinet level 2 ,Class II hepa filter biological safety cabinet |
School Lab ce Certified Class II A2 Biosafety Cabinet
Class II A2 Biosafety Cabinet Main Advantage:
◆ LCD Display
It shall work no less than 30, 000 hours continually.
◆ Negative pressure plenum surrounds contaminated positive pressure plenum; No fabric bags are used.
◆ One-piece removable work surface easy to clean.
◆ Frameless sash, easy to clean.
◆ Filter, Blower and Fluorescent lamp working time check.
◆ Have a front window operation safety cabinet, the operator can through the front window operation in safety enclosure.
◆ Airflow into the operation port to protect personnel
◆ Downdraft filtered by high efficiency filter to protect product
◆ The contaminated airflow is filtered by a high efficiency filter and discharged to protect the environment
Model | BSC-1300A2 |
Clean Grade | HEPA:ISO 5 calss ( Class100 ) |
ULPA:ISO 4 Class ( Class10 ) | |
HEPA Filter | HEPA:≥99.995% , @0.3μm |
ULPA:≥99.999% , @0.12μm | |
Air tightness | 99.99≤E≤99.999 |
Overall Dimensions | 1500×800×2120 mm |
Working Space | 1300×700×600 mm |
Inside of the door | 0.38±0.025m/s |
Front inflow air | 0.48±0.025m/s |
Class II A2 Biosafety Cabinet Product introduction:
It is widely used in biosafety protection and isolation equipment in microbiology, biomedicine, biological laboratories and other laboratories. It adopts advanced air purification technology and negative pressure cabinet design to realize the protection of the environment, personnel and samples and prevent harmfulness. The diffusion of suspended particles and aerosols.
BSC-II-A2 biological safety cabinet series is a level II A2 biological safety cabinet with 70% gas circulation and 30% gas exhaust.
Installation of Class II A2 Biosafety Cabinet :
1. The biological safety cabinet shall not be placed on its side, impacted, or collided during transportation, and shall not be directly attacked by rain, snow, or sun exposure.
2. The working environment of the biological safety cabinet is 10~30℃ and the relative humidity is <75%.
3. The equipment should be installed on a horizontal surface that cannot be moved.
4. The equipment must be installed close to a fixed power socket. When the external exhaust system is not connected, the top of the device must be at least 200mm away from the obstacle at the top of the room, and the distance between the back and the wall must be at least 300mm to facilitate the smooth flow of external exhaust. Maintenance of safety cabinets.
5. In order to prevent airflow interference, it is required that the equipment should not be installed in the passages of people, and the operating port of the sliding front window of the biological safety cabinet should not be directly facing the doors and windows of the laboratory or too close to the doors and windows. Places that may disturb the airflow.
6. When used in high altitude areas, the wind speed must be recalibrated after installation.
Company Details
Business Type:
Distributor/Wholesaler,Trading Company
Year Established:
2016
Total Annual:
1800000-2000000
Employee Number:
80~90
Ecer Certification:
Active Member
The company uses the business philosophy that is fully integrated with the market economy and efficient management and operation mechanism, takes the market as the guide, and builds a "customer-centric" marketing system based on customer needs. Ensure to provide customers with high-quality... The company uses the business philosophy that is fully integrated with the market economy and efficient management and operation mechanism, takes the market as the guide, and builds a "customer-centric" marketing system based on customer needs. Ensure to provide customers with high-quality...
Get in touch with us
Leave a Message, we will call you back quickly!