China Professional KIC Thermal Profiler KIC start Thermal Profiler 6 Channels for
China Professional KIC Thermal Profiler KIC start Thermal Profiler 6 Channels for

  1. China Professional KIC Thermal Profiler KIC start Thermal Profiler 6 Channels for
  2. China Professional KIC Thermal Profiler KIC start Thermal Profiler 6 Channels for
  3. China Professional KIC Thermal Profiler KIC start Thermal Profiler 6 Channels for

Professional KIC Thermal Profiler KIC start Thermal Profiler 6 Channels for

  1. MOQ: KIC start 1 set
  2. Price: KIC start exw price is 1200usd/set
  3. Get Latest Price
Payment Terms TT,western union,paypal and so on
Supply Ability KIC start 3000sets per month
Delivery Time KIC start within 15 days after payment
Packaging Details KIC start packing with wooden case
Usage Industrial, reflow oven temeperature profile test
Theory Temperature Recorder and Analytical instruments
Brand Name: KIC start
Usage: Industrial, reflow oven temeperature profile test
Theory: Temperature Recorder
Accuracy: ±0.5℃(Full scale), ±0.5℃(Full scale)
Temperature range: -150℃~1050℃
Resolution: Variable 0.3C to 0.1C
Internal Operating Temp: 0C to 105C
Sample Rate: 0.1 to 10 per second
Brand: Temperature Record Analysis
Brand Name kic thermal profiler
Model Number KIC start
Certification CE
Place of Origin USA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms TT,western union,paypal and so on Supply Ability KIC start 3000sets per month
Delivery Time KIC start within 15 days after payment Packaging Details KIC start packing with wooden case
Usage Industrial, reflow oven temeperature profile test Theory Temperature Recorder and Analytical instruments
Brand Name: KIC start Usage: Industrial, reflow oven temeperature profile test
Theory: Temperature Recorder Accuracy: ±0.5℃(Full scale), ±0.5℃(Full scale)
Temperature range: -150℃~1050℃ Resolution: Variable 0.3C to 0.1C
Internal Operating Temp: 0C to 105C Sample Rate: 0.1 to 10 per second
Brand: Temperature Record Analysis Brand Name kic thermal profiler
Model Number KIC start Certification CE
Place of Origin USA
High Light thermal profiler equipmentreflow oven temperature profile

Professional KIC Thermal Profiler KIC start Thermal Profiler with 6 Channels for Reflow Oven  

 

KIC START thermal profiler specifications:

1 .6 channels
2. accuracy +/-1.2degree
3. temperature range -150 to 1050 degree
4. resolution variable 0.3C to 0.1C
5. KIC start

KIC START thermal profiler:

 

The KICstart is a 6 channel datalogging thermal profiler. It features a more robust hardwareconfiguration than any other profiler on the market and an all new easy to use software platform. When theKICstart profiler has completed its run through the process, the internally logged profile is ready to bedownloaded to a computer.

The KICstart software features minimal initial setup and a radically simplified operator interfacethat eliminates tedious board mapping and oven measuring. The software is designed to be completelyintuitive and requires very little training. A series of screens with clear explanatory graphics guides youthrough the profiling process from beginning to end.

 

The KICstart uses different technology to complete its task of running profiles. The main differencebetween it and other profilers is the following:

 

Air thermocouple – For all profiles run with the KICstart software the thermocouple pluggedinto the first channel on the KICstart must be the Air TC. This TC is positioned 1 inch in front ofthe leading edge of the board for all profiles run using KICstart software.

 

Trigger temperatures – The KICstart uses trigger temperatures to start and stop the profile. TheStart temperature is defaulted to 2 degrees above the Maximum Product Start temperature. SeeGlobal Preferences for this value.

 

Hardware Monitor - The combination of the KICstart and the KICstart software closely monitorsthe KICstartbattery, internal temperature and the product temperature even before you start aprofile. There are built-in checks in the software to insure that the product and KICstart are coolenough and battery voltage sufficient to complete a profile safely. As well it will offertroubleshooting suggestions if there is a problem with communication or thermocoupleattachment.

 

Perfect Data – Through patent pending technology the KICstart is able to get you perfect dataevery time. At the completion of a profile the KICstart retransmits the data it has stored in itsmemory, once the communication cable is connected.

 

KIC START thermal profiler spec:

 

Accuracy +/- 2ºF (1.2ºC)
Resolution Variable 0.3 to 0.1ºC
Internal Operating Temp 0ºC to 105ºC
Thermocouple Compatibility Type K, 6TCs
Temperature Range -150ºC to 1050ºC
Computer Compatibility PC
Power Requirements 9V Alkaline battery
Dimension Varies depending upon model and shield

 

 

Process Window Index

 

 

The PWI is a single statistical number that measures how well your profile fits within your product`s thermal process window. The PWI provides an instant and objective conclusion whether your product profile is in spec, eliminating guesswork and opinion from process analysis. This helps you ensure that all your products on all your lines are manufactured with measurable, consistent quality

 

 

Mininum PC Requirements

 

400 MHz processor Celeron / 128Mb RAM

1 Gb available storage (for Product history records)

SVGA video 1024 x 768 resolution, 16-bit color

1 available serial port or USB port

1 available parrallel port or USB port

Operating system: soft® Windows® 2000, XP

 

1 When the KICstart software is running on the same computer as the oven controller, and/or when additionalKICstart options are installed, a faster CPU and more RAM may be required.

2 A USB to Serial adapter is used to connect the KICstart for profiling.

3 Contact KIC for issues with operating systems other than those listed.

Wickon hightesh offers temperature profiling systems in six major areas:

 

Oven Tracker Systems for the finishing, paint and powder coating industries

 

Furnace Tracker Systems for heat treatment processes and furnace surveys

 

Kiln Tracker Systems for tunnel & roller hearth kilns used in the process of firing ceramic products

 

Reflow Tracker Systems for PCB and electronics board manufacturing

 

Solar Tracker Systems for solar photovoltaic (PV) manufacturing

 

Food Tracke Systems for food processing

 

KIC START thermal profiler picture show:

  

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter,Seller

  • Year Established:

    1998

  • Total Annual:

    50000000-1000000000

  • Employee Number:

    20~50

  • Ecer Certification:

    Site Member

Shenzhen wickon electronic technology Co.,Ltd(shenzhen Meraif import and export Co., Ltd) is a professional high-tech enterprise,which specilizes in providing Surface Mount Technology (SMT ) service,wickon /meraif 's mainly products include SMT Equipment , SMT spare parts and SMT consumable ... Shenzhen wickon electronic technology Co.,Ltd(shenzhen Meraif import and export Co., Ltd) is a professional high-tech enterprise,which specilizes in providing Surface Mount Technology (SMT ) service,wickon /meraif 's mainly products include SMT Equipment , SMT spare parts and SMT consumable ...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Meraif Import And Export Co., Ltd.
  • A1517, Guanhualiantou Commercial Building, West Coast Garden Complex, Jincheng Road, Haoyi Community, Shajing Street, Baoan District, Shenzhen
  • MissJOY Liang
  • +8613424013606
  • https://www.smtproductionline.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement