China 4 Pole AC 40kA Voltage Limiting SPD Surge Protector
China 4 Pole AC 40kA Voltage Limiting SPD Surge Protector

  1. China 4 Pole AC 40kA Voltage Limiting SPD Surge Protector

4 Pole AC 40kA Voltage Limiting SPD Surge Protector

  1. MOQ: 200 piece
  2. Price: Negotiate
  3. Get Latest Price
Payment Terms T/T, L/C, Western Union
Supply Ability 60000 pieces per month
Delivery Time 5-15 days after payment
Packaging Details export package / Negotiate
Uc 385V
Condition 100% Original
CertificationCE,CQC CE / CQC / SGS
System voltage 220V
Environment temperature (-25℃~+80℃)
Status indicator Green-OK; red-replace
Response time (L-N) ≤25ns
Protection rating IP 20
In(8/20μs) 20kA
Imax(8/20μs) 40kA
Up 1.8KV
pole 4 poles
SPD type voltage limiting type SPD
Brand Name Uchi
Model Number OBV-II40-5
Certification CE / SGS / ISO9001
Place of Origin Dongguan China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, Western Union Supply Ability 60000 pieces per month
Delivery Time 5-15 days after payment Packaging Details export package / Negotiate
Uc 385V Condition 100% Original
CertificationCE,CQC CE / CQC / SGS System voltage 220V
Environment temperature (-25℃~+80℃) Status indicator Green-OK; red-replace
Response time (L-N) ≤25ns Protection rating IP 20
In(8/20μs) 20kA Imax(8/20μs) 40kA
Up 1.8KV pole 4 poles
SPD type voltage limiting type SPD Brand Name Uchi
Model Number OBV-II40-5 Certification CE / SGS / ISO9001
Place of Origin Dongguan China
High Light Voltage Limiting SPD Surge ProtectorAC SPD Surge Protector40kA 4 Pole Surge Protection Device

4 Poles 40kA Surge Protector Voltage Limiting Type For AC Power System

 

OBV-II40-5 data:

Uc(maximum continuous operating voltage) 385V
Imax(maximum discharge current) 40kA
In(nominal discharge current for class II test) 20kA
Up(voltage protection level) ≤1.8kv
Combination 1P,2P,3P,4P,1+1;3+1
response time ≤25ns
Signal deterioration indication Red: replace
Green:ok
Housing Material thermoplastic material
Housing self-extinguishing class UL94_V0
Temperature range -40℃+80℃
humidity range 5%RH~95%RH
Elevational ≤3000m
Method of connecting wire Parallel Connect
Thread Dimensions 4~35mm2
Mounting method DIN:35mm
IP(degree of protection of enclosure) IP20
Follow up standard IEC 61643-1,GB/T 18802.1

 


 

Installation Instructions:

(1) surge special circuit breaker or a fuse or circuit breaker must be installed at the front end of the surge protector to prevent the damage of the switching SPD and its lines caused by the power frequency continuous current caused by lightning strike, and to prevent the line fault caused by the increase of leakage current caused by the aging of the voltage limiting devices.

(2) The surge protector must be installed by a professional, and the power supply should be disconnected during installation. Connect the ground terminal first, then connect the other lines.

(3) once the surge protector is installed, do not change the installation position and wiring mode of the product at will, otherwise it will affect the function of the lightning protection system.

 

Usage:

System voltage limiting surge protector, suitable for installation in 220V/380V(50/60Hz) or 230V/400V(50/60Hz) low voltage power supply and distribution system, It is usually installed in the lightning protection zone LPZ0, LPZ1 or LPZ1, LPZ2, computer room, monitoring machine room, fire fighting machine room, telephone machine room, office and home building power distribution machine room and other weak current machine room. It is designed to protect low-voltage electrical devices from inducted lightning strike and surge harm. This product has the advanced structure design, the high quality material device, the reliable manufacturing process, the excellent safety performance, provides the omni-directional lightning protection for the electrical equipment.

 

Parameters:
1. SPD Type:voltage limiting type SPD;
2. Maximum Continuous Operating Voltage: 385V
3. Nominal Discharge Current :20KA
4. Voltage Protection Level: 1.8KV
5. Response Time: <25ns
6. Discontinuous Current Capability:no continuous flow
7. Single Stage Width: 18mm
8. Connector Wire Diameter: > 8mm2
9. Operating Status Indicator: window red replacement

 

The type of SPD:
1. According to the working principle divided:voltage switching type SPD, voltage limiting type SPD , voltage cobination type SPD
2. According to the use of points : power system surge protection device, signal system surge protection device

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2002

  • Total Annual:

    10000000-20000000

  • Employee Number:

    400~500

  • Ecer Certification:

    Active Member

Guangdong uchi Technology Co., Ltd. has been rooted in the lightning protection industry for more than ten years. It specializes in lightning protection device maintenance technical services and lightning protection scheme design. The company has a rich product line and covers a wide area, which can... Guangdong uchi Technology Co., Ltd. has been rooted in the lightning protection industry for more than ten years. It specializes in lightning protection device maintenance technical services and lightning protection scheme design. The company has a rich product line and covers a wide area, which can...

+ Read More

Get in touch with us

  • Reach Us
  • Guangdong Uchi Technology Co.,Ltd
  • Floor 4, NO.25-29,Power Station Road, Xihu , Shilong Town , Dongguan 523325, China.
  • MissAmy
  • 13925862052
  • https://www.surgeprotectiondevicespd.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement