| Payment Terms | T/T |
| Supply Ability | 100pcs/month |
| Delivery Time | 2 work days |
| Packaging Details | Standard Export Package |
| Intergrating Sphere Size | 154mm |
| Wavelength | 360nm-780nm |
| Specular Component | SCI&SCE |
| Reflectance Range | 0-200% |
| Illuminance | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
| Size | 370*300*200mm |
| Optional accessories | Printer, transmissive test clamp component |
| Language | Simplified Chinese, English, Traditional Chinese |
| Brand Name | Silk |
| Model Number | YS6060 |
| Certification | CE,RoHs,ISO,ASTM etc. |
| Place of Origin | China |
View Detail Information
Explore similar products
Reflectance Silk Spectrophotometer Benchtop Grating YS6010 For Liquid Color
spectophotometer YS4560 colour measurement instruments with color match program
Powder Coatings Colour Measurement Spectrophotometer Silk YS3060 With Powder
Benchtop Grating Silk Spectrophotometer YS6010 Transmission Reflectance To
Product Specification
| Payment Terms | T/T | Supply Ability | 100pcs/month |
| Delivery Time | 2 work days | Packaging Details | Standard Export Package |
| Intergrating Sphere Size | 154mm | Wavelength | 360nm-780nm |
| Specular Component | SCI&SCE | Reflectance Range | 0-200% |
| Illuminance | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 | Size | 370*300*200mm |
| Optional accessories | Printer, transmissive test clamp component | Language | Simplified Chinese, English, Traditional Chinese |
| Brand Name | Silk | Model Number | YS6060 |
| Certification | CE,RoHs,ISO,ASTM etc. | Place of Origin | China |
| High Light | hunter lab spectrophotometer ,color measurement instruments | ||
Multi function reflective fastness opacity strength garder index Pt-co Index color CIE LAB spectrophotometer
Brief Introduce:
YS6060 is a benchtop grating spectrophotometer which is developed by Silk independently with independent intellectual property. YS6060 has many features, like 7 inches TFT capacitive touch screen display, full illuminants, reflective d/8 and transmissive d/0 geometry (including or excluding UV). With very stable and precise color measurement, large storage and powerful PC software all makes YS6060 ideal for color analysis within R&D and laboratory environments.
Features:
1. Support full illuminants.
2. d/8 optical geometry for reflectance, d/0 for transmittance; both SCI&SCE, UV I+E
3. φ25.4mm/15mm/8mm/4mm multiple measuring apertuers as automative as flexible.
4. UV measurement is availble ,given wavelength range 360nm-780nm, built-in 400nm cut off/420nm cut off 460nm cut off(only xenon lamp edition)
5. Multiple accessories,sample holders,fixation frame are offered as standard to adapt to different working conditions and testing circumstances.
Application Industry:
YS6060 benchtop spectrophotometer is the precise color analysis and transmission in labs,applied in different industries,such as plastics, electronics,paint and ink, printing,garmets,leather,paper,auto,medical,cosmetics,food,science institute,labs.
Technical Specification:
| YS6060 | Specification |
| Optical Geometry |
Reflectance: d/8 (SCI⪰ Include UV/Exclude UV) Transmittance: d/0 (SCI⪰ Include UV/Exclude UV) Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
| Specular Component |
Reflectance: SCI&SCE Transmittance: SCI&SCE |
| Integrating Sphere Size | Φ 154mm |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Light Source Device | 360nm-780nm Combined LED Lamp, 400nm cut-off, 420nm cut-off, UV Lamp |
| Illuminants | D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
| Spectrophotometric Mode | Concave Grating |
| Observer Angle | 2° & 10° |
| Repeatability |
Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.03 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
| Inter-instrument Error |
Φ25.4mm/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) |
| Wavelength Range | 360-780nm |
| Wavelength Pitch | 10nm |
| Semiband Width | 10nm |
| Reflectance Range | 0~200% |
| Measuring Aperture |
Reflective: Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; Transmissive: Φ30mm/Φ25.4mm; |
| Color Space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy |
| Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 |
| Displayed Data | Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset |
| Colorimetric Index |
WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM E313, CIE/ISO), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, |
| PC Terminal Software | SQCX |
| Data Storage Capacity |
Standard: 5000 Pcs; Sample: 40000 Pcs. (One PCS can include both SCI and SCE) |
| Data Port | USB & Bluetooth |
| Locating Method | Camera Locating |
| Measurement Mode | Single Measurement & Average Measurement |
| Screen | 7" TFT Capacitive Screen-touch Display |
| Light Source Device Life | 5 years, more than 3 million times measurements. |
| Power Supply | DC 24V, 2A Power Adapter |
| Size | 370×300×200mm |
| Weight | 16kg |
| Language | English & Chinese |
| Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation) |
| Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
| Standard Accessory | White and Black Calibration Board, Checking Green Board, Sample Holder, Φ4mm, Φ8mm, Φ15mm, Φ25.4mm Aperture, Power Adapter, USB Cable, User Guide, PC Software |
| Optional Accessory | Micro-printer, Transmissive Test Clamp Component |
![]()
![]()
![]()
![]()
![]()
Attached:
Related knowledge about spectrophotometer
Color Space
CIE LAB
-L(Lightness)-0 is black,100 is white
-a(Red-Green)-positive values are red; negative values are green and 0 is neutral
-b(Blue-Yellow)-positive values are yellow;negative values are blue abd 0 is neutral
CIE LCH
L: Lightness,value is the same in each scale C:Chroma H:Hue Angle
dE Total Color difference
Delta-E is a measurement used to indicate how much a color deviates from an accepted standards.The higher the dE, the more inaccurate the color.
Contact information:
Contact Person: Clara
Email: L001@Silk.com
WhatsApp & Wechat ID: +8613510310267
Skype : clara.Silk
Company Details
Business Type:
Manufacturer
Year Established:
1998
Total Annual:
10000-50000
Employee Number:
100~200
Ecer Certification:
Active Member
The company is also the authorized agent of Philips and Sylvania. All products are widely used in plastic electronics, paint and ink, textile and dyeing, printing paper, food, medicine, cosmetics, scientific research, schools, laboratories, optical image testing ,and other fields. The company has ga... The company is also the authorized agent of Philips and Sylvania. All products are widely used in plastic electronics, paint and ink, textile and dyeing, printing paper, food, medicine, cosmetics, scientific research, schools, laboratories, optical image testing ,and other fields. The company has ga...
Get in touch with us
Leave a Message, we will call you back quickly!