Payment Terms | T/T |
Supply Ability | 10EA |
Delivery Time | 3-5 working days |
Packaging Details | Original |
Product Brand | B&R |
Product Model | X67BC8321.L12 |
Product Type | Bus controller |
Inputs/Outputs | 16 digital channels |
I/O power supply | 24 VDC |
Dimensions | 53*155*42 mm |
Weight | 350g |
Warranty | 1 Year |
Brand Name | B&R |
Model Number | X67BC8321.L12 |
Certification | CE |
Place of Origin | Austria |
View Detail Information
Explore similar products
X20AI4632 B&R X20 System PLC I/O Module 4 Analog Inputs ±10 V Or 0 To 20 MA
X20AO4622 B&R X20 System PLC I/O Module 4 Analog Outputs ±10 V Or 0 To 20 MA / 4
X20BC0083 B&R X20 PLC SYSTEM Bus Controller POWERLINK V1/V2 Controlled Node
X20DS1319 B&R X20 PLC SYSTEM 4 Digital Input Channels Configurable As Inputs Or
Product Specification
Payment Terms | T/T | Supply Ability | 10EA |
Delivery Time | 3-5 working days | Packaging Details | Original |
Product Brand | B&R | Product Model | X67BC8321.L12 |
Product Type | Bus controller | Inputs/Outputs | 16 digital channels |
I/O power supply | 24 VDC | Dimensions | 53*155*42 mm |
Weight | 350g | Warranty | 1 Year |
Brand Name | B&R | Model Number | X67BC8321.L12 |
Certification | CE | Place of Origin | Austria |
High Light | X67BC8321.L12 ,B&R X67 SYSTEM |
X67BC8321.L12
The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler.
Additional X2X Link I/O nodes (X67 modules or other modules based on X2X Link) can be connected using the integrated X2X Link connection. Mechanically, POWERLINK is connected via an IP67-rated standard D-coded M12 Ethernet connector.
POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.
Bus controller | POWERLINK (V1/V2) controlled node |
Inputs/Outputs | 16 digital channels, configurable as inputs or outputs using software, inputs with additional functions |
Insulation voltage between channel and bus | 500 Veff |
Nominal voltage | 24 VDC |
B&R ID code | |
Bus controller | 0xA90E |
Internal I/O module | 0x1A1D |
Sensor/Actuator power supply | 0.5 A summation current |
Status indicators | I/O function per channel, supply voltage, bus function |
Diagnostics | |
Outputs | Yes, using LED status indicator and software |
I/O power supply | Yes, using LED status indicator and software |
Connection type | |
Fieldbus | M12, D-coded |
X2X Link | M12, B-coded |
Inputs/Outputs | 8x M12, A-coded |
I/O power supply | M8, 4-pin |
Power output | 15 W X2X Link power supply for I/O modules |
Power consumption | |
Fieldbus | 4.2 W |
Internal I/O | 2.5 W |
X2X Link power supply | 24.3 W at maximum power output for connected I/O modules |
Certifications | |
CE | Yes |
UKCA | Yes |
ATEX | Zone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X |
UL | cULus E115267 Industrial control equipment |
HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
EAC | Yes |
KC | Yes |
Fieldbus | POWERLINK (V1/V2) controlled node |
Type | Type 2 |
Variant | 2x M12 interface (hub), 2x female connector on module |
Line length | Max. 100 m between 2 stations (segment length) |
Transfer rate | 100 Mbit/s |
Transfer | |
Physical layer | 100BASE-TX |
Half-duplex | Yes |
Full-duplex | No |
Autonegotiation | Yes |
Auto-MDI/MDIX | Yes |
Hub propagation delay | 0.96 to 1 µs |
Min. cycle time | |
Fieldbus | 200 μs |
X2X Link | 200 μs |
Synchronization between bus systems possible | Yes |
Nominal voltage | 24 VDC |
Voltage range | 18 to 30 VDC |
Integrated protection | Reverse polarity protection |
Power consumption | |
Sensor/Actuator power supply | Max. 12 W |
Voltage | I/O power supply minus voltage drop for short-circuit protection |
Voltage drop for short-circuit protection at 0.5 A | Max. 2 VDC |
Summation current | Max. 0.5 A |
Short-circuit proof | Yes |
Input characteristics per EN 61131-2 | Type 1 |
Input voltage | 18 to 30 VDC |
Input current at 24 VDC | Typ. 4 mA |
Input circuit | Sink |
Input filter | |
Hardware | ≤10 μs (channels 1 to 4) / ≤70 µs (channels 5 to 16) |
Software | Default 0 ms, configurable between 0 and 25 ms in 0.2 ms intervals |
Input resistance | Typ. 6 kΩ |
Additional functions | 50 kHz event counting, gate measurement |
Switching threshold | |
Low | <5 VDC |
High | >15 VDC |
Quantity | 2 |
Signal form | Square wave pulse |
Evaluation | Each negative edge, cyclic counter |
Input frequency | Max. 50 kHz |
Counter 1 | Input 1 |
Counter 2 | Input 3 |
Counter frequency | Max. 50 kHz |
Counter size | 16-bit |
Quantity | 1 |
Signal form | Square wave pulse |
Evaluation | Positive edge - Negative edge |
Counter frequency | |
Internal | 48 MHz, 3 MHz, 187.5 kHz |
Counter size | 16-bit |
Length of pause between pulses | ≥100 µs |
Pulse length | ≥20 µs |
Supported inputs | Input 2 or input 4 |
Variant | Current-sourcing FET |
Switching voltage | I/O power supply minus residual voltage |
Nominal output current | 0.5 A |
Total nominal current | 8 A |
Output circuit | Source |
Output protection | Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection of the output power supply |
Diagnostic status | Output monitoring with 10 ms delay |
Leakage current when the output is switched off | 5 µA |
Switching on after overload shutdown | Approx. 10 ms (depends on the module temperature) |
Residual voltage | <0.3 V at 0.5 A nominal current |
Peak short-circuit current | <12 A |
Switching delay | |
0 → 1 | <400 µs |
1 → 0 | <400 µs |
Switching frequency | |
Resistive load | Max. 100 Hz |
Inductive load | See section "Switching inductive loads". |
Braking voltage when switching off inductive loads | 50 VDC |
Electrical isolation | Bus isolated from POWERLINK and channel Channel not isolated from channel |
Mounting orientation | |
Any | Yes |
Installation elevation above sea level | |
0 to 2000 m | No limitation |
>2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
Degree of protection per EN 60529 | IP67 |
Temperature | |
Operation | -25 to 60°C |
Derating | - |
Storage | -40 to 85°C |
Transport | -40 to 85°C |
Dimensions | |
Width | 53 mm |
Height | 155 mm |
Depth | 42 mm |
Weight | 350 g |
Torque for connections | |
M8 | Max. 0.4 Nm |
M12 | Max. 0.6 Nm |
Company Details
Business Type:
Distributor/Wholesaler,Exporter,Trading Company,Seller
Year Established:
2013
Total Annual:
2350000-3125000
Employee Number:
>100
Ecer Certification:
Verified Supplier
Joyoung International Trading Co.,Ltd is not only the world's leading industrial equipment supplier, but also has been committed to the production of automation control system modules and spare parts for ten years. We are located in Xiamen, a famous tourist city in China. We are the w... Joyoung International Trading Co.,Ltd is not only the world's leading industrial equipment supplier, but also has been committed to the production of automation control system modules and spare parts for ten years. We are located in Xiamen, a famous tourist city in China. We are the w...
Get in touch with us
Leave a Message, we will call you back quickly!