Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure","imgUrl":"https:\/\/img.chinax.com\/nimg\/fc\/b2\/d1f80985db7bdcd829634edc0e18-200x200-1\/industrial_door_protection_light_grid_with_ce_certification_26amp_3b_ip67_enclosure.jpg","attrs":{"Brand Name":"JUTAI","Model Number":"CL20-8L","Certification":"CE","Place of Origin":"China"}}
{"title":"30ms Quick Response IP67 Waterproof Safety Light Curtain For Industrial High","imgUrl":"https:\/\/img.chinax.com\/nimg\/d2\/de\/8bc47c53fb3487bd37fa66151482-200x200-1\/30ms_quick_response_ip67_waterproof_safety_light_curtain_for_industrial_high_speed_doors.jpg","attrs":{"Brand Name":"JUTAI","Model Number":"CL20-8L","Certification":"CE","Place of Origin":"China"}}
{"title":"1500mm Length Blanking Infrared Light Curtain 8m Detecting Range Fast Door","imgUrl":"https:\/\/img.chinax.com\/nimg\/b3\/ec\/90b79d659bc6281b1d7eefd41894-200x200-1\/1500mm_length_blanking_infrared_light_curtain_8m_detecting_range_fast_door_sensor.jpg","attrs":{"Feature":"Corrosion Resistant","IP Rating":"IP67","Operating Current":"<50mA","Operating Temperature":"-20~60\u2103"}}
{"title":"IP67 Blanking Infrared Light Curtain","imgUrl":"https:\/\/img.chinax.com\/nimg\/b3\/ec\/90b79d659bc6281b1d7eefd41894-200x200-1\/ip67_blanking_infrared_light_curtain.jpg","attrs":{"Brand Name":"JUTAI","Model Number":"CL15-8L8","Certification":"CE","Place of Origin":"China"}}
{"title":"8 Beam 1.5m Blanking Light Curtain Sensor With No\/Nc Output And Aluminum Alloy","imgUrl":"https:\/\/img.chinax.com\/nimg\/b3\/ec\/90b79d659bc6281b1d7eefd41894-200x200-1\/8_beam_1_5m_blanking_light_curtain_sensor_with_no_2fnc_output_and_aluminum_alloy_shell.jpg","attrs":{"Feature":"Corrosion Resistant","Operating Temperature":"-20~60\u2103","Output":"No\/Nc, COM","Brand Name":"JUTAI"}}
{"title":"Safety Blanking Light Curtain Sensor For Inductrial Door Rapid Door Safety","imgUrl":"https:\/\/img.chinax.com\/nimg\/1c\/ac\/3ecde57fb6f6f25b0ce95a1b358a-200x200-1\/safety_blanking_light_curtain_sensor_for_inductrial_door_rapid_door_safety_control.jpg","attrs":{"Feature":"Corrosion Resistant","Operating Current":"<50mA","Brand Name":"JUTAI","Model Number":"CL15-8L8"}}
{"title":"Industrial Gate 150cm 8 Group Beams Photocell Anti Pinch Safety Light Curtain 8m","imgUrl":"https:\/\/img.chinax.com\/nimg\/c4\/ec\/028add98643880fee99bcbca8572-200x200-1\/industrial_gate_150cm_8_group_beams_photocell_anti_pinch_safety_light_curtain_8m_range.jpg","attrs":{"Sensing Distance":"8m","Working Current":"<20mA@DC12V","Supply Voltage":"DC12-24V","Specification":"150*2.1*1.5cm"}}
Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure
The JUTAI CL20-8L Industrial Door Protection Light Grid is a CE-certified safety sensing solution designed exclusively for industrial door scenarios. It forms an 8-beam invisible protective grid between the emitter and receiver, instantly triggering safety responses (door reversal, stopping) when personnel, objects, or equipment intrude the detection area. With an IP67 waterproof/dustproof enclosure and rugged aluminum alloy construction, it delivers reliable anti-pinch and intrusion protection for industrial doors in harsh industrial environments, ensuring compliance with safety standards and operational continuity.
Core Specifications
Parameter
Specification
Model
CL20-8L
Certification
CE certified (compliant with safety standards for industrial machinery)
Protection Rating
IP67 (dustproof + waterproof)
Housing Material
Aluminum alloy
Working Voltage
DC12-24V
Working Current
Transmitter: <65mA @DC12V; Receiver: <20mA @DC12V
Output Configuration
NO/NC relay output (default NO, configurable to NC); COM terminal included
Operating Range (Emitter to Receiver)
1-8m
Maximum Protection Height
1729mm
Number of Photocells
8 beams
Cable Length
Transmitter: 8m; Receiver: 4m
Connector Type
Transmitter: 5-pole M8 male connector; Receiver: 5-pole M8 male connector
Operating Temperature
-20°C ~ +60°C
Key Function
Industrial door anti-pinch protection + Blanking Mode (anti-false alarm)
LED Status Indicators
Transmitter: Steady blue (normal operation); Fast-flashing red (voltage <9V or >28V) Receiver: Steady red (object/personnel blocked); Steady blue (no obstruction); Flashing blue (first power-on, emitter-receiver misalignment)
Installation Hole Dimensions (Unit: mm)
14, 29, 75, 80, 175, 19.7, 21.4, 259
Key Functions & Advantages
CE Certification & Safety Compliance: Meets international safety standards for industrial machinery, ensuring compliance with workplace safety regulations in global industrial settings. Rigorously tested for reliability and safety.
IP67 Enclosure for Harsh Environments: Fully dustproof and waterproof, withstanding temporary water immersion, heavy dust, and industrial contaminants. Aluminum alloy enclosure resists mechanical wear, vibration, and corrosion.
Targeted Industrial Door Protection: 8-beam light grid covers the full height of industrial doors (1729mm), eliminating safety blind spots and accurately detecting intrusions to prevent pinching/crushing accidents.
Blanking Mode for False Alarm Prevention: Specialized for industrial door gaps - blocking the first channel does not trigger safety responses, adapting to sequential beam blocking during normal door closure.
Easy Installation & Intuitive Operation: Color-coded wiring simplifies connection to industrial door control systems. LED indicators provide real-time status feedback for quick troubleshooting.
Wiring Guide
Component
Wire Color
Function
Detailed Notes
Transmitter
Red
DC12-24V Positive Power Supply
Connect to a stable DC power supply; avoid overvoltage/undervoltage to prevent device damage
Transmitter
Black
Ground (GND)
Connect to power supply negative terminal; ensure reliable grounding to avoid signal interference
Transmitter
Green
Reserve
No connection required for basic use
Transmitter
Yellow
Reserve
No connection required for basic use
Transmitter
White
Reserve
No connection required for basic use
Receiver
Red
DC12-24V Positive Power Supply
Use the same power source as the transmitter for consistent voltage
Receiver
Black
Ground (GND)
Shared ground with the transmitter to ensure signal stability
Receiver
Green
NO/NC Output (Default NO)
Connect to the industrial door control system's safety signal input terminal
Receiver
Yellow
Configurable NC
Switches to NC output after Blanking Mode activation (matches door control system requirements)
Receiver
White
COM (Common Terminal)
Must be connected to the door control system's corresponding terminal for normal output function
Critical Warnings: Do NOT connect NO/NC terminals (Green/Yellow wires of the receiver) to the power supply positive terminal - this will permanently damage the optical relay. Keep connecting cables away from high-voltage/high-current conductors to avoid signal interference or cable damage.
Blanking Mode Activation Steps
Complete wiring according to the Wiring Guide and confirm no connection errors.
Power on the light grid (ensure the power supply meets DC12-24V requirements).
Within 1 minute of power-on, touch the receiver's Green wire (NO output) to its Black wire (GND) five consecutive times.
Observe the receiver's Red light blinking - this indicates successful activation: The Yellow wire switches to NC mode, and Blanking Mode is enabled.
Test the function: Normal door closure (blocking the first channel) will not trigger safety responses; intrusion of personnel/objects will trigger immediate door reversal/stopping.
Application Scenarios
Industrial Fast Doors: High-speed roll-up doors in factories, logistics centers, and production lines.
Roller Shutter Doors: Industrial roller shutters in warehouses, workshops, and loading docks.
Sectional Industrial Doors: Large industrial doors in factories, storage facilities, and industrial parks.
Special Environment Industrial Doors: Cold storage industrial doors, outdoor industrial doors, and dusty workshop doors (resistant to temperature extremes, dust, and moisture).
Troubleshooting
Fault Symptoms
Possible Causes
Detailed Solutions
Receiver's blue light flashes continuously after power-on
Emitter and receiver misalignment (light beams not paired)
1. Adjust the mounting positions to ensure both devices are parallel. 2. Remove obstacles blocking the light path between emitter and receiver. 3. Tighten mounting screws to avoid vibration-induced misalignment.
Transmitter's red light flashes fast
Power supply voltage <9V or >28V
1. Use a multimeter to test the power supply voltage. 2. Replace with a stable DC12-24V power supply. 3. Check for voltage drops caused by long cables and replace with thicker cables if necessary.
Light grid works normally (LED indicators correct), but door has no anti-pinch action
Wiring error (incorrect connection of NO/NC or COM terminal)
1. Recheck wiring against the guide - ensure Green/Yellow (output) and White (COM) terminals are connected to the door control system's safety interface. 2. Verify the door control system is set to "external safety sensor input" mode.
Unable to enter Blanking Mode
1. Operation exceeds 1-minute window after power-on 2. Light leakage during door descent 3. Bottommost beam blocked by debris 4. Door/obstruction fails to meet minimum continuous blocking distance
1. Power off and restart, then activate within 1 minute. 2. Fix door sealing to prevent light leakage. 3. Clear debris blocking the bottommost beam. 4. Adjust the door or obstruction to meet the continuous blocking distance requirement.
Installation Guidelines
Pre-Installation Preparation: Confirm the industrial door's opening height and width - ensure the light grid's protection height (1729mm) and operating range (1-8m) match. Prepare a stable DC12-24V power supply and check the device for intact components.
Mounting Operation: Install the emitter and receiver vertically on both sides of the industrial door frame, ensuring the light grid covers the full door opening without blind spots. Align the device's installation holes with the door frame, fix with matching screws. Route the 8m (transmitter) and 4m (receiver) cables along the door frame, avoiding sharp edges or high-pressure areas.
Wiring & Debugging: Follow the Wiring Guide to connect power, ground, and signal cables - double-check to avoid positive/negative reversal or incorrect output terminal connections. Power on the device: Confirm the transmitter's steady blue light and receiver's steady blue light (normal power-on). Align the light grid: If the receiver's blue light flashes, adjust the emitter/receiver positions until the light stabilizes. Activate Blanking Mode as instructed and test the anti-pinch function to ensure normal operation.
Usage & Maintenance Caveats
Cable Protection: Keep cables away from high-voltage conductors, door machinery, and forklift paths to avoid extrusion, damage, or interference.
Lens Maintenance: Regularly wipe the emitter/receiver lenses with a dry, soft cloth to remove dust, oil stains, or condensation - dirty lenses will affect detection accuracy.
Physical Protection: Do not bend, twist, or drop the device; avoid scratching the aluminum alloy housing or infrared lenses.
Light Source Avoidance: Prevent direct sunlight or other infrared light sources from shining on the receiver to avoid false triggers.
Blanking Mode Usage: Ensure the door or obstruction used for Blanking Mode meets the minimum continuous blocking distance requirement.
Regular Inspection: Periodically test the anti-pinch and Blanking Mode functions; check wiring tightness and connector integrity to ensure long-term reliability.
Customer Success Stories
"JUTAI's sensor eliminated downtime in our cold storage facility. The IP67 rating ensured reliable operation even at -25°C." -- Michael Chen, Warehouse Manager, Leading Cold Chain Logistics Provider
"The dual-mode feature allowed seamless integration into our existing infrastructure. Installation was effortless!" -- Lisa Wang, Safety Engineer, Global Automotive Manufacturer
"JUTAI's CE-certified sensor met our safety standards while reducing maintenance costs by 30%." -- David Li, Plant Director, International Pharmaceutical Corporation
"After installing JUTAI's 16-beam sensor, we saw a 100% reduction in conveyor-related incidents." -- Sarah Zhang, Safety Officer, Top E-commerce Fulfillment Center
Shenzhen Jutai COMM Co., Ltd. is a high-tech privately-owned enterprise that integrates production, research and development, and sales. Our company is dedicated to the research and development as well as system integration of security products, achieving an intelligent one unified platform that int... Shenzhen Jutai COMM Co., Ltd. is a high-tech privately-owned enterprise that integrates production, research and development, and sales. Our company is dedicated to the research and development as well as system integration of security products, achieving an intelligent one unified platform that int...