LD-200 Dual Channel Inductive Loop Detector for Parking Barrier Gate Vehicle

  1. MOQ: 1
  2. Price: Negotiation
  3. Get Latest Price
LD-200 Power 100-240VAC
Loop Spacing 1m spacing between loops
Payment Terms T/T,L/C,D/A,D/P,Western Union,Paypal,Alipay
Loop Inputs CH1 Loop + CH2 Loop
Sensitivity Range 0.015% to 0.8%
Working Modes 6 Selectable Modes
Delivery Time 5 - 8 working days
Detection Channels 2 Channels
Frequency Range 20-100kHz
LD-202 Power 12-24VAC/DC
Auto Reset Time 10 Minutes in Normal Mode
Supply Ability 1000 pieces per month
Sensitivity Levels 8 Levels per Channel
Packaging Details Cartoon
Model LD-200 / LD-202
Frequency Levels High / Medium-High / Medium-Low / Low
Model Number LD-200
Certification CE
Brand Name JUTAI
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

LD-200 Power 100-240VAC Loop Spacing 1m spacing between loops
Payment Terms T/T,L/C,D/A,D/P,Western Union,Paypal,Alipay Loop Inputs CH1 Loop + CH2 Loop
Sensitivity Range 0.015% to 0.8% Working Modes 6 Selectable Modes
Delivery Time 5 - 8 working days Detection Channels 2 Channels
Frequency Range 20-100kHz LD-202 Power 12-24VAC/DC
Auto Reset Time 10 Minutes in Normal Mode Supply Ability 1000 pieces per month
Sensitivity Levels 8 Levels per Channel Packaging Details Cartoon
Model LD-200 / LD-202 Frequency Levels High / Medium-High / Medium-Low / Low
Model Number LD-200 Certification CE
Brand Name JUTAI Place of Origin China
High Light dual channel loop detectorinductive loop detector for parkingvehicle presence detection loop detector
LD-200 Dual Channel Inductive Loop Detector for Parking Barrier Gate Vehicle Direction and Presence Detection
LD-200/LD-202 Dual Channel Vehicle Loop Detector
LD-200 / LD-202 Dual Channel Vehicle Loop Detector

The JUTAI LD-200 / LD-202 is a dual-channel inductive vehicle loop detector designed for parking barrier gates, vehicle entrance and exit control, access control systems and traffic management applications.

Unlike a single-channel detector, the dual-channel design can connect two independent inductive loops, CH1 and CH2, allowing one detector to monitor two vehicle detection zones. The two-loop configuration also supports vehicle direction detection, making the detector particularly suitable for parking entrances, exits and bidirectional vehicle lanes.

The detector provides configurable presence and pulse relay outputs, eight sensitivity levels for each channel, four selectable operating frequency levels and six operating modes for different parking and traffic control requirements.


Key Features
Dual Channel Vehicle Detection

LD-200 / LD-202 supports two independent loop inputs:

  • CH1 Loop
  • CH2 Loop

Both channels can detect vehicles independently, allowing one detector to perform the functions normally requiring two separate single-channel detection circuits.

This makes it suitable for:

  • Parking entrance and exit lanes
  • Barrier gate control
  • Vehicle presence detection
  • Direction recognition
  • Traffic control
  • Vehicle passage logic
Vehicle Direction Detection

One of the key advantages of the dual-loop design is direction detection.

Two loops can be installed sequentially in the vehicle travel path. For example:

CH1 → CH2 can be interpreted as one travel direction, while CH2 → CH1 can be interpreted as the opposite direction.

This allows the controller to distinguish vehicle entry and exit movements and generate the corresponding CH1 or CH2 relay output according to the selected operating mode.


Six Selectable Working Modes

The detector provides six operating modes for different control requirements:

Mode 1 – Direction Pulse Detection

Detects the sequence between CH1 and CH2 and produces a relay pulse after the vehicle leaves the corresponding loop.

Mode 2 – Direction Presence Detection

Uses the two-loop sequence to determine direction and generates a presence output according to the selected travel direction.

Mode 3 – Alternative Direction Presence Logic

Provides another dual-loop direction-control logic for applications requiring different vehicle entry and exit output timing.

Mode 4 – Independent Two-Channel Detection

CH1 and CH2 operate as separate vehicle presence detection channels. This mode is useful when two independent loops need to be monitored without direction detection.

Mode 5 – Entry Pulse Detection

When a vehicle enters CH1 or CH2, the corresponding relay generates a pulse output.

Mode 6 – Exit Pulse Detection

The corresponding relay generates a pulse after the vehicle leaves CH1 or CH2.

This flexible mode structure allows the same detector to be used for both simple dual-loop detection and more advanced vehicle direction applications.


8-Level Independent Sensitivity Adjustment

Each channel provides 8 selectable sensitivity levels:

Sensitivity Level
Highest 0.015%
0.02%
0.04%
0.08%
0.12%
0.2%
0.5%
Lowest 0.8%

This allows the installer to adjust CH1 and CH2 according to:

  • Loop size
  • Vehicle type
  • Installation conditions
  • Required detection sensitivity

The manual also provides a special sensitivity increase function for applications such as trailers, where stable presence detection is important.


20-100kHz Adjustable Frequency

The operating frequency can be adjusted from approximately 20kHz to 100kHz using four selectable frequency levels:

  • High
  • Medium-High
  • Medium-Low
  • Low

Frequency adjustment is useful when multiple loops are installed close to each other because different frequency settings can help reduce interference between adjacent detection loops.


Automatic Reset and Permanent Presence

The detector supports two vehicle-presence behaviors:

Permanent Presence Mode

A detected vehicle can remain continuously present without automatic reset until the vehicle leaves the loop or the detector is manually reset.

Automatic Reset Mode

In Normal Mode, the detector automatically resets after approximately 10 minutes of continuous vehicle presence. This can help recover from abnormal or unintended long-duration detection conditions.


Technical Specifications
Parameter Specification
Product Type Dual Channel Vehicle Loop Detector
Model LD-200 / LD-202
Detection Channels 2
Loop Inputs CH1 + CH2
LD-200 Power Supply 100-240VAC
LD-202 Power Supply 12-24VAC/DC
Sensitivity Levels 8 Levels per Channel
Sensitivity Range 0.015%-0.8%
Frequency Range 20-100kHz
Frequency Settings High / Medium-High / Medium-Low / Low
Working Modes 6 Modes
Direction Detection Supported
Independent CH1 / CH2 Detection Supported
Presence Detection Supported
Pulse Output Supported
Automatic Reset Supported
Auto Reset Time Approx. 10 Minutes
Permanent Presence Supported
Trailer Sensitivity Increase Supported
CH1 Output Relay COM / NO
CH2 Output Relay COM / NO
Loop Fault Indication LED Indication
Configuration DIP Switch
Main Application Parking / Barrier Gate / Vehicle Access / Traffic Control

Typical Applications
Parking Barrier Gates

Detects vehicles approaching, passing through or leaving a parking barrier gate and provides signals to the barrier controller.

Parking Entrance and Exit Direction Detection

Two loops installed sequentially can distinguish vehicle travel direction according to the CH1/CH2 detection sequence.

Two Independent Vehicle Detection Zones

When direction detection is not required, CH1 and CH2 can operate as two separate presence channels.

Vehicle Access Control

Can provide vehicle presence or pulse signals to compatible access-control and gate-control equipment.

Parking Counting and Traffic Logic

The CH1 → CH2 or CH2 → CH1 sequence can be used by the connected control system for vehicle flow and direction logic.


Loop Installation

The manual recommends configuring loop turns according to the total loop perimeter:

Loop Perimeter Recommended Turns
3-4m 6 Turns
4-6m 5 Turns
6-10m 4 Turns
10-20m 3 Turns
Above 20m 2 Turns

For a typical dual-loop direction-detection installation, the manual illustrates CH1 and CH2 as two separate loops placed along the vehicle travel path, with approximately 1m spacing between the two detection loops.


Why Choose a Dual Channel Loop Detector?

Compared with a single-channel vehicle detector, the LD-200 / LD-202 provides several important advantages:

  • One detector supports two inductive loops
  • Supports vehicle direction detection
  • CH1 and CH2 can also work independently
  • 8 sensitivity levels for each channel
  • 6 configurable operating modes
  • Presence and pulse output options
  • 20 -100kHz frequency adjustment
  • Automatic reset and permanent presence modes
  • Suitable for entrance and exit vehicle control

For parking system integrators, this makes the dual-channel detector particularly useful where two loops, vehicle direction recognition or more flexible barrier-control logic are required.

Loop Detector Connection Diagram
Indicators and Switches
  • Power LED (RED): Illuminates to indicate "Power ON"
  • CH1 Detection LED:
    • Steady On: Vehicle detection
    • Slow Blinking: Loop short circuit or insufficient twists
    • Fast Blinking: Loop open circuit or excessive twists
  • CH2 Detection LED:
    • Steady On: Vehicle detection
    • Slow Blinking: Loop short circuit or insufficient twists
    • Fast Blinking: Loop open circuit or excessive twists
Sensitivity Selection

Sensitivity and frequency adjustment is facilitated through 7-way and 10-way dip switch settings:

  • 8 different sensitivity settings available via dip switch configuration
  • Dip switches 6, 7, and 8 govern CH1 sensitivity (0.8 to 0.015)
  • Dip switches 3, 4, and 5 control CH2 sensitivity (0.8 to 0.015)
Sensitivity Selection Diagram
Switch Configuration

Switch 1 (S1) - Channel 1 Loop Function Selection:

  • DIP 1 & DIP 2: Special Sensitivity Increase For Both Trailer (Both Channels)
  • D3, D4, D5 and Switch 2 D1, D2: Special Functions (Mode1, 2, 3 Direction Detection. Mode 4, 5, 6 Normal mode)
  • D6 & D7 & D8 and Switch 2 D3 & D4 & D5: CH1 and CH2 Sensitivity Selection (Eight Levels)
  • D9 & D10 and Switch2 D6, D7: Frequency Selection (20 K to 100 KHz)
Switch Configuration Diagram 1 Switch Configuration Diagram 2 Switch Configuration Diagram 3 Switch Configuration Diagram 4
Reset Button Note: The LD-200 must be reset every time a setting change is made to the Dip switches.
Installation Guidelines
  • Coil cutting size should be rectangle: length 1.0 to 2.0 meters, width 0.8 to 1.2 meters
  • Avoid right angles at corners as much as possible
  • Use ferromagnetic wires for induction coil, total length up to 500 meters
  • Keep product plug and socket in vertical direction during installation
Coil Installation Overview Installation Orientation
System Integration

The JUTAI LD200/202 double-channel vehicle loop detector series, equipped with direction recognition function, is ideal for single-channel entry and exit scenarios when integrated with:

  • JUTAI One door controller (Model: AC-11)
  • JUTAI gate barrier (Model: BR-110)
  • JUTAI long-range RFID reader (Model: PUHF-9)
  • High-temperature resistance loop coils (Model: JTHT-11)
System Integration Diagram
Working Principle
Entry Process
  1. Car enters community/parking lot, pressing two loop coils simultaneously
  2. LD-200/202 triggers UHF reader at entrance
  3. UHF reader reads card ID and sends to controller via Wiegand output
  4. Controller verifies ID validity and outputs relay signal to open gate barrier
  5. Car enters, barrier arm lowers automatically
  6. LD-100/102 provides safety and anti-smashing functionality
Exit Process
  1. Car exits community/parking lot, passing inside UHF reader
  2. LD-200/LD-202 triggers UHF reader to read card and send ID to controller
  3. Controller verifies ID validity and outputs relay signal to open gate barrier
  4. Car exits, barrier arm lowers automatically
  5. LD-100/102 provides safety and anti-smashing functionality
Direction Recognition

The Direction Recognition Function ensures the double channels loop detector does not trigger the signal again when the car passes another UHF reader, recording only entry or exit records in the system.

Working Principle Diagram
Independent Operation Mode

The JUTAI LD-200/202 Double Channel Loop Detector can also function as two independent single-channel loop detectors, suitable for standard one-in and one-out parking lots.

This configuration provides cost-saving benefits by reducing hardware costs associated with using separate detectors for each function.

Independent Operation Diagram Additional Application Diagram 1 Additional Application Diagram 2

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2012

  • Total Annual:

    120000-150000

  • Employee Number:

    50~70

  • Ecer Certification:

    Verified Supplier

Shenzhen Jutai COMM Co., Ltd. is a high-tech privately-owned enterprise that integrates production, research and development, and sales. Our company is dedicated to the research and development as well as system integration of security products, achieving an intelligent one unified platform that int... Shenzhen Jutai COMM Co., Ltd. is a high-tech privately-owned enterprise that integrates production, research and development, and sales. Our company is dedicated to the research and development as well as system integration of security products, achieving an intelligent one unified platform that int...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Jutai Comm Co., Ltd.
  • 5f, Xuxingda Industrial Park, Shiyan, Baoan, Shenzhen, Guangdong, China
  • https://www.accesssecuritysolution.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement