China MTL5514 MTL Switch Proximity Detector Interface 10ms
China MTL5514 MTL Switch Proximity Detector Interface 10ms

  1. China MTL5514 MTL Switch Proximity Detector Interface 10ms
  2. China MTL5514 MTL Switch Proximity Detector Interface 10ms
  3. China MTL5514 MTL Switch Proximity Detector Interface 10ms
  4. China MTL5514 MTL Switch Proximity Detector Interface 10ms

MTL5514 MTL Switch Proximity Detector Interface 10ms

  1. MOQ: 1
  2. Price: Negotiate
  3. Get Latest Price
Payment Terms T/T
Supply Ability 1000pcs per week
Delivery Time stock
Packaging Details carton
Manufacturer MTL Instruments
Product No MTL5514
Number of channels One
Response time 10ms maximum
Warranty 1 Year
Maximum current consumption 25mA at 24V dc
Brand Name MTL
Model Number MTL5514
Certification HART
Place of Origin UK/China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 1000pcs per week
Delivery Time stock Packaging Details carton
Manufacturer MTL Instruments Product No MTL5514
Number of channels One Response time 10ms maximum
Warranty 1 Year Maximum current consumption 25mA at 24V dc
Brand Name MTL Model Number MTL5514
Certification HART Place of Origin UK/China
High Light MTL5514 MTL SwitchMTL5514 Proximity DetectorProximity Detector 10ms

MTL5514 MTL Switch/Proximity Detector Interface Response time 10ms maximum

 

The MTLx514 enables a safe–area load to be controlled, through a relay, by a proximity detector or switch located in a hazardous area. Line faults
are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection

 

 

  • Number of channels

    One

  • Location of switch

    Zone 0, IIC, T6 hazardous area

    Div.1, Group A, hazardous location

  • Location of proximity detector

    Zone 0, IIC, T4–6 hazardous area, if suitably certified

    Div.1, Group A, hazardous location

  • Hazardous–area inputs

    Inputs conforming to BS EN60947–5–6:2001 standards for

    proximity detectors (NAMUR)

  • Voltage applied to sensor

    7 to 9V dc from 1kΩ ±10%

  • Input/output characteristics

    Normal phase

    Outputs closed if input > 2.1mA (< 2kΩ in input circuit)

    Outputs open if input < 1.2mA (> 10kΩ in input circuit)

    Hysteresis: 200µA (650Ω) nominal

  • Line fault detection (LFD) (when selected)

    User-selectable via switches on the side of the unit. Line faults

    are indicated by an LED. Line fault relay is energised and channel

    output relay de-energised if input line-fault detected

    Open-circuit alarm on if Iin < 50µA

    Open-circuit alarm off if Iin > 250µA

    Short-circuit alarm on if Rin < 100Ω

    Short-circuit alarm off if Rin > 360Ω

    Note: Resistors must be fitted when using the LFD facility with a contact input

    500Ω to 1kΩ in series with switch

    20kΩ to 25kΩ in parallel with switch

  • Safe-area output

    Channel: Single pole relay with changeover contacts

    LFD: Single pole relay with changeover contacts

    Note: reactive loads must be adequately suppressed

13-600x600-0.jpg

 

 

 

 

 

 

HCU16 MTL5521 MTL4575
HCU3700 MTL5522 MTL4646Y
HM64RIB20-1.0 MTL5531 MTL4850
HM64RIB20-1.5 MTL5532 MTL4851
HMM64 MTL5541 MTL4852
HMRIB16-1.0 MTL5541S MTL5018
HMS64 MTL5544 MTL5032
HTP-SC32 MTL5544D MTL5042
MTL4044D MTL5546 MTL5044
MTL4511 MTL5546Y MTL5049
MTL4516 MTL5561 MTL5511
MTL4516C MTL5573 MTL5514D
MTL4521 MTL5575 MTL5516
MTL4541 MTL5582B MTL5516C
MTL4541 MTL7728+ MTL7787P+
MTL4544 MTL7756AC MTLCPS16
MTL4544D MTL7760AC NJ5-18GK-N
MTL4546Y MTL7761PAC SD150X
MTL4549Y MTL7765AC SD32
MTL4573 MTL7787+ SD32X
TP48-4-N-NDI TP48-3-N-NDI SDRTD
TP48-N-NDI TP48-4-I-NDI SLP32D

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Distributor/Wholesaler,Agent,Trading Company

  • Year Established:

    2012

  • Total Annual:

    3000000-5000000

  • Employee Number:

    20~30

  • Ecer Certification:

    Verified Supplier

Achievers Automation Limited We are a global supplier of quality automation and control components, dedicated to meeting the industrial control needs of businesses worldwide. Over12 years of industry experience. Operates a full range of industrial automation components and instruments, cooperatin... Achievers Automation Limited We are a global supplier of quality automation and control components, dedicated to meeting the industrial control needs of businesses worldwide. Over12 years of industry experience. Operates a full range of industrial automation components and instruments, cooperatin...

+ Read More

Get in touch with us

  • Reach Us
  • Achievers Automation Limited
  • RM 509, 5/F, THE CLOUD, 111,TUNG CHAU STREET, TAI KOKTSUI, KOWLOON,HONG KONG
  • https://www.achieversinstruments.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement