Payment Terms | T/T |
Supply Ability | 100pcs per month |
Delivery Time | Negotiable |
Packaging Details | carton |
Manufacturer | PEPPERL FUCHS |
Product No | LB5105A |
Connection | backplane bus |
Power dissipation | 0.75 W |
Linearity error | 0.1 % |
Relative humidity | 95 % non-condensing |
Altitude | max. 2000 m |
Brand Name | PEPPERL FUCHS |
Model Number | LB5105A |
Place of Origin | Germany |
View Detail Information
Explore similar products
Pepperl Fuchs Female cordset V1-W-A2-5M-PUR Built-in LED, as operating and
Pepperl Fuchs Ultrasonic direct detection sensor UB100-F77-E2-V31
Pepperl Fuchs Capacitive sensor CBB8-18GS75-E2 8 mm flush
Pepperl Fuchs Inductive sensor NCN25-F35-A2-250-V 1Minimum bending radius of 30
Product Specification
Payment Terms | T/T | Supply Ability | 100pcs per month |
Delivery Time | Negotiable | Packaging Details | carton |
Manufacturer | PEPPERL FUCHS | Product No | LB5105A |
Connection | backplane bus | Power dissipation | 0.75 W |
Linearity error | 0.1 % | Relative humidity | 95 % non-condensing |
Altitude | max. 2000 m | Brand Name | PEPPERL FUCHS |
Model Number | LB5105A | Place of Origin | Germany |
High Light | Pepperl Fuchs Thermocouple Converter ,Thermocouple Converter 0.75W ,LB5105A Module |
Pepperl+Fuchs LB5105A Module Thermocouple Converter with Backplane Bus Connection and 0.75 W Power Dissipation
Slots
Occupied slots 2
Supply
Connection backplane bus
Rated voltage 12 V DC , only in connection with the power supplies LB9***
Power dissipation 0.75 W
Power consumption 0.75 W
Internal bus
Connection backplane bus
Interface manufacturer-specific bus to standard com unit
Input
Compensation (reference junction CJC) internal cold junction compensation or external cold junction
temperature input
Number of channels 4
Suitable field devices
Field device [2] Thermocouple
Field device [4] mV source
Suitable sensors
Sensor thermocouples U, B, E, T, K, S, R, L, J, N, Pallaplat and mV sources
Connection channel I: 1+, 2-; channel II: 5+, 6-; channel III: 9+, 10-; channel IV: 13+, 14-
Measuring range -65 ... 75 mV with LFD , -75 ... 75 mV without LFD
Smallest span 5 mV for 0.1 % accuracy
Linearity error 0.1 %
Conversion time max. 300 ms (4 channels) without LFD max. 600 ms (4-channel) with LFD
Compensation (reference junction CJC) internal cold junction compensation or external cold junction
Line fault detection can be switched on/off for each channel via configuration tool ,
Open-circuit > 1 kΩ
Transfer characteristics
Deviation
Influence of ambient temperature max. 0,1 %/10 K
Indicators/settings
LED indication Power LED (P) green: supply
Status LED (I) red: line fault (collective alarm) , red flashing: communication error
Coding optional mechanical coding via front socket
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013
Company Details
Business Type:
Distributor/Wholesaler,Agent,Trading Company
Year Established:
2012
Total Annual:
3000000-5000000
Employee Number:
100~115
Ecer Certification:
Verified Supplier
Achievers Automation Limited is a well-established player in the field of industrial automation, boasting a rich and extensive experience of more than 12 years. Over these years, the company has dedicated itself to dealing with a comprehensive and complete range of industrial automation components a... Achievers Automation Limited is a well-established player in the field of industrial automation, boasting a rich and extensive experience of more than 12 years. Over these years, the company has dedicated itself to dealing with a comprehensive and complete range of industrial automation components a...
Get in touch with us
Leave a Message, we will call you back quickly!