| Acid Concentration | 94.5% H2SO4 |
| Payment Terms | T/T, L/C |
| Overall Dimensions | Φ520 × 6750 × 960 mm |
| Design Pressure (Tube) | 0.8 MPa |
| Acid Inlet Temperature | 63°C |
| Tube Material | 316L Stainless Steel |
| Sealing Form | Double Gasket with PTFE Seal |
| Design Pressure (Shell) | 0.6 MPa |
| Shell Material | 304L Stainless Steel |
| Type | Shell and Tube Anodic Protection Sulfuric Acid Cooler |
| Anode Material | Platinum-Clad Titanium |
| Design Temperature | 120°C |
| Heat Exchange Area | 70 m² |
| Flow Form | Acid Shell Side / Cooling Water Tube Side |
| Supply Ability | 1000 Sets/Year |
| Acid Flow Rate | 28000 Kg/h |
| Delivery Time | 60 Workdays |
| Cathode Material | Hastelloy C-276 |
| Acid Outlet Temperature | 36°C |
| Packaging Details | Naked Packing with Protective Frame |
| Weight | 3600 Kg |
| Tube Specification | Φ16 × 1.5 × 5200 mm |
| Flange Standards | ANSI B16.5 Class 150 / HG/T 20592 |
| Place of Origin | China |
| Brand Name | Carpe Diem |
| Model Number | CD-AP-70 |
| Certification | ISO 9001, ASME U Stamp |
View Detail Information
Explore similar products
Enhanced Corrosion Resistant Anodic Protection Cooler CD-AP-45 45m² 94% Sulfuric
Tailored 320m² Anodic Protection Sulfuric Acid Cooler CD-AP-320 Shell Tube Type
High-Efficiency Anodic Protection Sulfuric Acid Cooler CD-AP-280 280m² Shell
Industrial Anodic Protection Sulfuric Acid Cooler CD-AP-430 with Real-Time
Product Specification
| Acid Concentration | 94.5% H2SO4 | Payment Terms | T/T, L/C |
| Overall Dimensions | Φ520 × 6750 × 960 mm | Design Pressure (Tube) | 0.8 MPa |
| Acid Inlet Temperature | 63°C | Tube Material | 316L Stainless Steel |
| Sealing Form | Double Gasket with PTFE Seal | Design Pressure (Shell) | 0.6 MPa |
| Shell Material | 304L Stainless Steel | Type | Shell and Tube Anodic Protection Sulfuric Acid Cooler |
| Anode Material | Platinum-Clad Titanium | Design Temperature | 120°C |
| Heat Exchange Area | 70 m² | Flow Form | Acid Shell Side / Cooling Water Tube Side |
| Supply Ability | 1000 Sets/Year | Acid Flow Rate | 28000 Kg/h |
| Delivery Time | 60 Workdays | Cathode Material | Hastelloy C-276 |
| Acid Outlet Temperature | 36°C | Packaging Details | Naked Packing with Protective Frame |
| Weight | 3600 Kg | Tube Specification | Φ16 × 1.5 × 5200 mm |
| Flange Standards | ANSI B16.5 Class 150 / HG/T 20592 | Place of Origin | China |
| Brand Name | Carpe Diem | Model Number | CD-AP-70 |
| Certification | ISO 9001, ASME U Stamp | ||
| High Light | Anodic Protection Sulfuric Acid Cooler ,304L Shell Acid Cooler ,Compact 70m² Acid Cooler | ||
The Carpe Diem CD-AP-70 Anodic Protection Sulfuric Acid Cooler is a compact yet rigorously quality-assured shell and tube heat exchanger designed for smaller-scale sulfuric acid cooling applications where reliability and inspection integrity are paramount. With a 70m² heat exchange area, this unit cools 94.5% concentrated sulfuric acid from 63°C to 36°C at a flow rate of 28,000 Kg/h. The cooler features a 304L stainless steel shell housing a 316L stainless steel tube bundle with precision-drawn tubes measuring Φ16 × 1.5 × 5200mm. What truly distinguishes the CD-AP-70 is our uncompromising multi-stage non-destructive testing program. Every single unit undergoes a comprehensive five-stage NDT protocol: 100% radiographic examination of all butt welds, liquid dye penetrant inspection of all fillet and branch connection welds, ultrasonic thickness verification of all pressure boundary components, helium mass spectrometer leak testing of the complete tube bundle assembly, and full hydrostatic pressure testing of both shell and tube circuits. This exhaustive inspection regime, combined with the integrated anodic protection system featuring platinum-clad titanium anodes and Hastelloy C-276 cathodes, ensures that each CD-AP-70 delivers leak-free, corrosion-free operation from day one of commissioning. The compact footprint makes this model particularly suitable for pilot plants, laboratory-scale acid production units, small-capacity sulfur-burning plants, and specialized chemical processing facilities where space is at a premium but quality cannot be compromised.
Key Features| Parameter | Specification |
|---|---|
| Model | CD-AP-70 |
| Type | Shell and Tube Anodic Protection Sulfuric Acid Cooler |
| Heat Exchange Area | 70 m² |
| Acid Concentration (H&sb2;SO&sb4;) | 94.5% |
| Acid Inlet Temperature | 63°C |
| Acid Outlet Temperature | 36°C |
| Acid Flow Rate | 28,000 Kg/h |
| Overall Dimensions (Dia × L × H) | Φ520 × 6750 × 960 mm |
| Equipment Weight | 3,600 Kg |
| Shell Material | 304L Stainless Steel |
| Tube Material | 316L Stainless Steel |
| Tube Specification | Φ16 × 1.5 × 5200 mm |
| Flow Form | Acid Shell Side / Cooling Water Tube Side |
| Sealing Form | Double Gasket with PTFE Seal |
| Flange Standards | ANSI B16.5 Class 150 / HG/T 20592 |
| Anode Material | Platinum-Clad Titanium |
| Cathode Material | Hastelloy C-276 |
| Design Pressure (Shell / Tube) | 0.6 MPa / 0.8 MPa |
| Design Temperature | 120°C |
| Certification | ISO 9001, ASME U Stamp |
The CD-AP-70 Anodic Protection Sulfuric Acid Cooler is specifically designed for small-capacity sulfuric acid production and handling applications where full-scale industrial coolers would represent excessive capital investment and unnecessary excess capacity. Primary applications include pilot plant and laboratory-scale sulfuric acid production units used for process development and catalyst testing programs. The unit is also ideally sized for small sulfur-burning acid plants producing 50 to 150 metric tons per day, serving as both the absorption tower acid cooler and the final product acid trim cooler. In the chemical processing industry, the CD-AP-70 is deployed in batch sulfonation reactors, titanium dioxide sulfate-process pilot facilities, and small-scale metal pickling acid recovery systems. Pharmaceutical and specialty chemical manufacturers using high-purity sulfuric acid as a reaction medium or catalyst appreciate the compact footprint and rigorous quality documentation. The unit is also commonly specified for university chemical engineering laboratories and government research facilities where safety, reliability, and comprehensive inspection records are mandatory procurement requirements. Educational institutions conducting corrosion research on advanced anodic protection techniques frequently select this model as a reference platform.
Packaging & Quality AssuranceThe CD-AP-70 quality assurance program is among the most thorough in the industry for equipment of this size class. All incoming materials are verified against EN 10204 Type 3.1 certified mill test reports with additional positive material identification testing performed on all pressure-retaining components using portable optical emission spectroscopy. Welding operations are executed exclusively by ASME Section IX certified welders under fully qualified welding procedure specifications, with continuous monitoring by certified welding inspectors. The multi-stage NDT program includes 100% radiographic examination of all butt welds, 100% liquid penetrant examination of all fillet welds and nozzle attachment welds, ultrasonic thickness verification of all formed head knuckle regions, ferrite content measurement of all stainless steel welds using a calibrated ferritescope, and a comprehensive helium mass spectrometer leak test on the assembled tube bundle. Hydrostatic pressure testing is conducted at 1.5 times design pressure with digital pressure recording for complete traceability. The anodic protection control panel undergoes a 24-hour burn-in test with simulated load conditions prior to shipment. For transport, the compact CD-AP-70 is secured to a welded steel base frame with heavy-duty bolted flange covers and all instrument ports sealed with stainless steel plugs. The complete unit is wrapped in vapor-phase corrosion inhibitor film and enclosed in heavy-gauge polyethylene sheeting. A weatherproof document pouch attached to the shipping frame contains the full quality dossier: material certificates, NDT reports with digital radiography files on USB, hydrostatic test charts, helium leak test certificate, anodic protection system FAT report, surface finish inspection records, ASME U Stamp Manufacturer's Data Report, and a comprehensive installation and operating manual.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2017
Total Annual:
300$-1200$
Employee Number:
>50
Ecer Certification:
Verified Supplier
Jiangsu Carpe Diem Ocean Equipment Co., Ltd. is headquartered in the Li Shui International Enterprise R&D Park in Nanjing — a historic capital known as the “Ancient City of Six Dynasties.” The facility spans 17,000 square meters, including 8,000 square meters dedicated t... Jiangsu Carpe Diem Ocean Equipment Co., Ltd. is headquartered in the Li Shui International Enterprise R&D Park in Nanjing — a historic capital known as the “Ancient City of Six Dynasties.” The facility spans 17,000 square meters, including 8,000 square meters dedicated t...
Get in touch with us