China Precision Kerr Microscope Cryo MOKE System For Magnetization Imaging Of
China Precision Kerr Microscope Cryo MOKE System For Magnetization Imaging Of

  1. China Precision Kerr Microscope Cryo MOKE System For Magnetization Imaging Of

Precision Kerr Microscope Cryo MOKE System For Magnetization Imaging Of

  1. MOQ:
  2. Price: Price Negotiable | Contact us for a detailed quote
  3. Get Latest Price
Place Of Origin CHINA
Payment Terms T/T
Name Kerr Microscope
Electrical Source Meter SR830, Keithley 6221, Keithley 2182 A
Objectives 5×, 20×, 50×, 100×, Non-magnetic
Laser Spot 5 μm
Magnetic Field Resolution PID Closed-loop Feedback Regulation, Resolution 0.05 MT
Variable Temperature Range 4.2 K - 420 K
Vertical Magnetic Field Water-cooled Magnet, 1.6 T@air Gap 10.5 Mm At Room Temperature; 1 T@air Gap 24 Mm At Low Temperature
Kerr Angle Resolution 0.5 Mdeg (RMS)
In-Plane Magnetic Field Water-cooled Magnet, 1 T@air Gap 18 Mm At Room Temperature; 0.75 T@air Gap 28 Mm At Low Temperature
Brand Name Truth Instruments
Model Number KMPL-L

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Place Of Origin CHINA Payment Terms T/T
Name Kerr Microscope Electrical Source Meter SR830, Keithley 6221, Keithley 2182 A
Objectives 5×, 20×, 50×, 100×, Non-magnetic Laser Spot 5 μm
Magnetic Field Resolution PID Closed-loop Feedback Regulation, Resolution 0.05 MT Variable Temperature Range 4.2 K - 420 K
Vertical Magnetic Field Water-cooled Magnet, 1.6 T@air Gap 10.5 Mm At Room Temperature; 1 T@air Gap 24 Mm At Low Temperature Kerr Angle Resolution 0.5 Mdeg (RMS)
In-Plane Magnetic Field Water-cooled Magnet, 1 T@air Gap 18 Mm At Room Temperature; 0.75 T@air Gap 28 Mm At Low Temperature Brand Name Truth Instruments
Model Number KMPL-L
High Light Precision Kerr MicroscopeCryo MOKE SystemMOKE System Precision

Cryo MOKE System For Magnetization Imaging Of Spintronic Materials

Product Description:

The Cryogenic High-Magnetic-Field Laser Kerr Microimaging System is a cutting-edge instrument designed for researchers and scientists working with low temperature Kerr microscopy applications. This advanced system offers exceptional temperature stability with a range of ±50 mK, ensuring precise and reliable measurements even in demanding experimental conditions.

Featuring a high Kerr angle resolution of 0.5 mdeg (RMS), the system enables researchers to accurately analyze weak magnetic materials and perform detailed magnetization measurements with unparalleled precision. The included objectives provide flexibility and versatility, with magnification options of 5*, 20*, 50*, and 100*, as well as a non-magnetic objective for specialized applications.

One of the key highlights of this system is its magnetic field resolution capability, which is achieved through PID closed-loop feedback regulation with a resolution of 0.05 mT. This precise control over magnetic fields allows researchers to study magnetic properties of materials with exceptional control and accuracy, opening up new possibilities for groundbreaking research in the field of magnetism.

Moreover, the Cryogenic High-Magnetic-Field Laser Kerr Microimaging System offers a variable temperature range from 4.2 K to 420 K, catering to a wide range of experimental requirements and allowing researchers to study material behavior across different temperature regimes. This temperature versatility is essential for investigating the thermal properties of materials and understanding how they respond to temperature changes.

In summary, the Cryogenic High-Magnetic-Field Laser Kerr Microimaging System is a sophisticated instrument that excels in the analysis of low temperature Kerr microscopy applications. With its exceptional temperature stability, high Kerr angle resolution, versatile objectives, precise magnetic field regulation, and variable temperature range, this system is a valuable tool for researchers seeking to explore the magnetic properties of materials and conduct detailed magnetization measurements in a controlled laboratory setting.

 

Features:

  • Product Name: Cryogenic High-Magnetic-Field Laser Kerr Microimaging System
  • Electrical Source Meter:
    • SR830
    • Keithley 6221
    • Keithley 2182 A
  • Kerr Angle Resolution: 0.5 Mdeg (RMS)
  • Optical Resolution: 450 Nm
  • In-Plane Magnetic Field:
    • Water-cooled Magnet
    • 1 T @ air Gap 18 mm at Room Temperature
    • 0.75 T @ air Gap 28 mm at Low Temperature
  • Variable Temperature Range: 4.2 K - 420 K
 

Technical Parameters:

Objectives 5*, 20*, 50*, 100*, Non-magnetic
Electrical Source Meter SR830, Keithley 6221, Keithley 2182 A
Laser Spot 5 μm
Vertical Magnetic Field Water-cooled Magnet, 1.6 T@air Gap 10.5 Mm At Room Temperature; 1 T@air Gap 24 Mm At Low Temperature
Magnetic Field Resolution PID Closed-loop Feedback Regulation, Resolution 0.05 MT
In-Plane Magnetic Field Water-cooled Magnet, 1 T@air Gap 18 Mm At Room Temperature; 0.75 T@air Gap 28 Mm At Low Temperature
Optical Resolution 450 Nm
Temperature Stability ±50 MK
Variable Temperature Range 4.2 K - 420 K
Kerr Angle Resolution 0.5 Mdeg (RMS)
 

Applications:

Product Application Occasions and Scenarios for the Truth Instruments Cryogenic High-Magnetic-Field Laser Kerr Microimaging System (Model: KMPL-L) :

Brand Name: Truth Instruments

Model Number: KMPL-L

Place Of Origin: CHINA

In-Plane Magnetic Field: Water-cooled Magnet, 1 T@air Gap 18 Mm At Room Temperature; 0.75 T@air Gap 28 Mm At Low Temperature

Objectives: 5*, 20*, 50*, 100*, Non-magnetic

Kerr Angle Resolution: 0.5 Mdeg (RMS)

Temperature Stability: ±50 MK

Optical Resolution: 450 Nm

Product Application Scenarios:

- Magnetization measurement in various materials

- Low temperature magnetic characterization studies

- High-resolution imaging in low temperature environments

- Kerr microimaging analysis at cryogenic temperatures

- Research and development of materials with specific magnetic properties

This Cryogenic High-Magnetic-Field Laser Kerr Microimaging System by Truth Instruments (Model: KMPL-L) is designed for precise magnetization measurement and low temperature magnetic characterization. With its in-plane magnetic field capabilities and high Kerr angle resolution of 0.5 Mdeg (RMS), this system is ideal for studying materials at different magnetic field strengths and temperatures.

Researchers and scientists can utilize this system for in-depth analysis of materials in low temperature environments, exploring magnetic properties with non-magnetic objectives and achieving optical resolution of 450 Nm. The ±50 MK temperature stability ensures reliable and accurate results in various research scenarios.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2019

  • Total Annual:

    15.000.000-20.000.000

  • Employee Number:

    100~200

  • Ecer Certification:

    Verified Supplier

.gtr-container-d4e5f6 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; overflow: hidden; } .gtr-container-d4e5f6 p { font-size: 14px; margin-bottom: 1em; tex... .gtr-container-d4e5f6 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; overflow: hidden; } .gtr-container-d4e5f6 p { font-size: 14px; margin-bottom: 1em; tex...

+ Read More

Get in touch with us

  • Reach Us
  • Truth Instruments Co., Ltd.
  • 169 Zhuzhou Road, Laoshan District, Qingdao, Shandong Province, China
  • https://www.afmmicroscopes.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement