China factories

Chat Now Send Email
China factory - AiLF(Shandong)Instruments Co., Ltd.

AiLF(Shandong)Instruments Co., Ltd.

  • China,Beijing ,Liaoning
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Portable G10 TDLAS Methane Detector with Internal Pump and Probe
China Portable G10 TDLAS Methane Detector with Internal Pump and Probe

  1. China Portable G10 TDLAS Methane Detector with Internal Pump and Probe
  2. China Portable G10 TDLAS Methane Detector with Internal Pump and Probe

Portable G10 TDLAS Methane Detector with Internal Pump and Probe

  1. MOQ: 1
  2. Price: $12000~$15000
  3. Get Latest Price
Product Type Portable TDLAS Laser Methane Detector
Sampling System Integrated Gas Sampling Pump with Probe
Delivery Time 5-7 Work Days
Target Gas Methane (CH₄)
Calibration and Display Built-In Gas Cell Reference for Self-Calibration; ppm, %LEL, and %VOL Readings
Supply Ability 100 Units Per Month
Packaging Details 38*33*18cm 4.5kg
Primary Applications Natural Gas Pipeline Inspection, Utility Surveys, Industrial Leak Detection, and Methane Monitoring
Payment Terms T/T
Detection Technology Tunable Diode Laser Absorption Spectroscopy (TDLAS)
Model G10
Model Number G10
Place of Origin Shandong,China
Brand Name AiLF
Certification ATEX

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Product Type Portable TDLAS Laser Methane Detector Sampling System Integrated Gas Sampling Pump with Probe
Delivery Time 5-7 Work Days Target Gas Methane (CH₄)
Calibration and Display Built-In Gas Cell Reference for Self-Calibration; ppm, %LEL, and %VOL Readings Supply Ability 100 Units Per Month
Packaging Details 38*33*18cm 4.5kg Primary Applications Natural Gas Pipeline Inspection, Utility Surveys, Industrial Leak Detection, and Methane Monitoring
Payment Terms T/T Detection Technology Tunable Diode Laser Absorption Spectroscopy (TDLAS)
Model G10 Model Number G10
Place of Origin Shandong,China Brand Name AiLF
Certification ATEX
High Light 0.5ppm Portable Methane Detector ,Leakage Inspection Portable Methane Detector ,0.5ppm methane gas tester

G10 Portable Laser Methane Detector with Internal Pump


The G10 is a portable TDLAS laser methane detection system designed for natural gas pipeline inspections and industrial gas leak investigations. Featuring an integrated sampling pump and probe-based sampling configuration, it allows operators to collect gas samples from suspected leak locations and assess methane readings directly in the field.

Its portable design supports flexible operation across different inspection environments, making it suitable for routine pipeline surveys, targeted leak checks, and maintenance activities where convenient access to gas sampling points is important.


Integrated Pump and Probe-Based Sampling

The G10 incorporates an internal gas sampling pump to support active sampling during leak inspections. Used with a suitable sampling probe, the system helps operators investigate valves, pipe connections, utility installations, and other accessible locations where gas accumulation or leakage may be suspected.

An integrated filtration system supports the sampling process, while the probe configuration helps direct sampling toward selected inspection points. This design provides a practical solution for field technicians who need a portable instrument for systematic and targeted gas leak investigations.


Automatic Self-Calibration for Consistent Measurements

The G10 features a built-in gas cell reference that supports continuous self-calibration during operation. This function helps maintain measurement consistency and reduces the need for frequent manual calibration interventions, subject to the instrument's operating conditions and maintenance requirements.

Combined with laser-based sensing, the reference system supports reliable field measurements and helps operators evaluate potential methane leak indications during inspections.


Real-Time Gas Analysis and Flexible Readings

The G10 provides real-time measurement feedback to help operators assess changing gas concentrations during sampling. Its display supports concentration readings in ppm, %LEL, and %VOL, allowing users to review results in formats suited to different inspection and reporting needs.

The ability to assess gas readings at the inspection site helps streamline field workflows and supports timely decisions about whether a suspected leak requires further investigation.


TDLAS Technology for Selective Methane Detection

The G10 uses Tunable Diode Laser Absorption Spectroscopy (TDLAS) to detect methane through its characteristic optical absorption properties. This laser-based approach supports selective methane measurement and is designed for gas leak inspection in natural gas infrastructure and industrial environments.

By combining selective sensing with active sampling, the G10 provides a practical approach to investigating suspected leaks where direct measurement at a specific location is required.


Applications


Natural Gas Pipeline Inspection

Inspect accessible pipeline components, valves, connections, and utility infrastructure for potential methane leaks.

Urban Gas Utility Surveys

Support field inspections around gas distribution networks, service connections, and other accessible utility installations.

Industrial Facility Monitoring

Conduct targeted leak investigations in gas processing facilities, refineries, manufacturing plants, and other industrial environments.

Landfill and Biogas Monitoring

Assist with methane screening at landfill sites, biogas installations, and other facilities where methane emissions may occur.

Emergency Leak Investigation

Provide portable sampling and on-site gas analysis to support initial assessments of suspected gas leak locations, in accordance with site safety procedures.


A Practical Tool for Targeted Gas Leak Inspection

The G10 combines portable operation, integrated gas sampling, and laser-based methane analysis in one inspection instrument. Its internal pump, probe-based sampling, and built-in gas reference make it suitable for technicians who need a flexible solution for investigating suspected leaks across natural gas infrastructure and industrial facilities.


Model G10 Detection Subject  Methane(CH4)
Measuring Principle Laser Absorption Spectrum Display Unit PPM,%LEL,%VOL
Resolution 0.5 ppm Explosion-Proof Grade ATEX Exib IIC T4 Gb
Response Time 0.1 s Operating Temperature -20 ~ 50 ºC
Concentration Range 0~100% VOL Operating Humidity < 98%RH, no condensation
Enclosure Protection Class IP66 Main Unit Dimension 208 x 78 x 53 mm
Power supply and Endurance Lithium battery >10h Main Unit Weight 1.1 kg
Accessories Strap, hand-held probe Optional Accessories Bell-shaped probe,trolley

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2018

  • Employee Number:

    100~200

  • Ecer Certification:

    Verified Supplier

AiLF Instruments is an innovative high-tech company that applies laser gas detection technology and is committed to providing the industry with first-class products and solutions. With advanced technology accumulation and profound understanding of industrial applications, AILF Instruments has won... AiLF Instruments is an innovative high-tech company that applies laser gas detection technology and is committed to providing the industry with first-class products and solutions. With advanced technology accumulation and profound understanding of industrial applications, AILF Instruments has won...

+ Read More

Get in touch with us

  • Reach Us
  • AiLF(Shandong)Instruments Co., Ltd.
  • Room 603, Office Building of Liaoning Hotel, Xicheng District, Beijing, China
  • https://www.ailfinstruments.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement