| Product Type | Portable TDLAS Laser Methane Detector |
| Sampling System | Integrated Gas Sampling Pump with Probe |
| Delivery Time | 5-7 Work Days |
| Target Gas | Methane (CH₄) |
| Calibration and Display | Built-In Gas Cell Reference for Self-Calibration; ppm, %LEL, and %VOL Readings |
| Supply Ability | 100 Units Per Month |
| Packaging Details | 38*33*18cm 4.5kg |
| Primary Applications | Natural Gas Pipeline Inspection, Utility Surveys, Industrial Leak Detection, and Methane Monitoring |
| Payment Terms | T/T |
| Detection Technology | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Model | G10 |
| Model Number | G10 |
| Place of Origin | Shandong,China |
| Brand Name | AiLF |
| Certification | ATEX |
View Detail Information
Explore similar products
ATEX Certified G10E Real-Time Analysis quick response portable TDLAS Laser
Handheld Pump Type C10F Full Scale PPM LEL% VOL Display Laser TDLAS Methane
Portable G10 TDLAS Methane Detector with Trolley for Gas Leak Inspection
C10F Handheld Pump-Type TDLAS Methane Leak Detector with Multi-Unit Display
Product Specification
| Product Type | Portable TDLAS Laser Methane Detector | Sampling System | Integrated Gas Sampling Pump with Probe |
| Delivery Time | 5-7 Work Days | Target Gas | Methane (CH₄) |
| Calibration and Display | Built-In Gas Cell Reference for Self-Calibration; ppm, %LEL, and %VOL Readings | Supply Ability | 100 Units Per Month |
| Packaging Details | 38*33*18cm 4.5kg | Primary Applications | Natural Gas Pipeline Inspection, Utility Surveys, Industrial Leak Detection, and Methane Monitoring |
| Payment Terms | T/T | Detection Technology | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Model | G10 | Model Number | G10 |
| Place of Origin | Shandong,China | Brand Name | AiLF |
| Certification | ATEX | ||
| High Light | 0.5ppm Portable Methane Detector ,Leakage Inspection Portable Methane Detector ,0.5ppm methane gas tester | ||
G10 Portable Laser Methane Detector with Internal Pump
The G10 is a portable TDLAS laser methane detection system designed for natural gas pipeline inspections and industrial gas leak investigations. Featuring an integrated sampling pump and probe-based sampling configuration, it allows operators to collect gas samples from suspected leak locations and assess methane readings directly in the field.
Its portable design supports flexible operation across different inspection environments, making it suitable for routine pipeline surveys, targeted leak checks, and maintenance activities where convenient access to gas sampling points is important.
Integrated Pump and Probe-Based Sampling
The G10 incorporates an internal gas sampling pump to support active sampling during leak inspections. Used with a suitable sampling probe, the system helps operators investigate valves, pipe connections, utility installations, and other accessible locations where gas accumulation or leakage may be suspected.
An integrated filtration system supports the sampling process, while the probe configuration helps direct sampling toward selected inspection points. This design provides a practical solution for field technicians who need a portable instrument for systematic and targeted gas leak investigations.
Automatic Self-Calibration for Consistent Measurements
The G10 features a built-in gas cell reference that supports continuous self-calibration during operation. This function helps maintain measurement consistency and reduces the need for frequent manual calibration interventions, subject to the instrument's operating conditions and maintenance requirements.
Combined with laser-based sensing, the reference system supports reliable field measurements and helps operators evaluate potential methane leak indications during inspections.
Real-Time Gas Analysis and Flexible Readings
The G10 provides real-time measurement feedback to help operators assess changing gas concentrations during sampling. Its display supports concentration readings in ppm, %LEL, and %VOL, allowing users to review results in formats suited to different inspection and reporting needs.
The ability to assess gas readings at the inspection site helps streamline field workflows and supports timely decisions about whether a suspected leak requires further investigation.
TDLAS Technology for Selective Methane Detection
The G10 uses Tunable Diode Laser Absorption Spectroscopy (TDLAS) to detect methane through its characteristic optical absorption properties. This laser-based approach supports selective methane measurement and is designed for gas leak inspection in natural gas infrastructure and industrial environments.
By combining selective sensing with active sampling, the G10 provides a practical approach to investigating suspected leaks where direct measurement at a specific location is required.
Applications
Natural Gas Pipeline Inspection
Inspect accessible pipeline components, valves, connections, and utility infrastructure for potential methane leaks.
Urban Gas Utility Surveys
Support field inspections around gas distribution networks, service connections, and other accessible utility installations.
Industrial Facility Monitoring
Conduct targeted leak investigations in gas processing facilities, refineries, manufacturing plants, and other industrial environments.
Landfill and Biogas Monitoring
Assist with methane screening at landfill sites, biogas installations, and other facilities where methane emissions may occur.
Emergency Leak Investigation
Provide portable sampling and on-site gas analysis to support initial assessments of suspected gas leak locations, in accordance with site safety procedures.
A Practical Tool for Targeted Gas Leak Inspection
The G10 combines portable operation, integrated gas sampling, and laser-based methane analysis in one inspection instrument. Its internal pump, probe-based sampling, and built-in gas reference make it suitable for technicians who need a flexible solution for investigating suspected leaks across natural gas infrastructure and industrial facilities.
| Model | G10 | Detection Subject | Methane(CH4) |
| Measuring Principle | Laser Absorption Spectrum | Display Unit | PPM,%LEL,%VOL |
| Resolution | 0.5 ppm | Explosion-Proof Grade | ATEX Exib IIC T4 Gb |
| Response Time | 0.1 s | Operating Temperature | -20 ~ 50 ºC |
| Concentration Range | 0~100% VOL | Operating Humidity | < 98%RH, no condensation |
| Enclosure Protection Class | IP66 | Main Unit Dimension | 208 x 78 x 53 mm |
| Power supply and Endurance | Lithium battery >10h | Main Unit Weight | 1.1 kg |
| Accessories | Strap, hand-held probe | Optional Accessories | Bell-shaped probe,trolley |
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2018
Employee Number:
100~200
Ecer Certification:
Verified Supplier
AiLF Instruments is an innovative high-tech company that applies laser gas detection technology and is committed to providing the industry with first-class products and solutions. With advanced technology accumulation and profound understanding of industrial applications, AILF Instruments has won... AiLF Instruments is an innovative high-tech company that applies laser gas detection technology and is committed to providing the industry with first-class products and solutions. With advanced technology accumulation and profound understanding of industrial applications, AILF Instruments has won...
Get in touch with us
Leave a Message, we will call you back quickly!