Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 80000pcs/year |
Delivery Time | 1-30 working days |
Packaging Details | standard export package, or as per customer request |
Specificaition | DKFXRS-19II/CY/ air source heat pump water heater |
Power | 220V~240V/50Hz/1ph 380V~415V/50Hz/3ph |
Condenser | High efficiency shell and tube heat exchanger |
Function | Cooling,Heating,hot water,heating/hot water,DHW |
Refrigerant | R410A,R407C/R410A,R22/R407C,R143a,R407c |
Compressor type | Copeland EVI compressor |
Brand Name | LN |
Model Number | DKFXRS-38II/CY |
Certification | CE ISO CCC |
Place of Origin | China |
View Detail Information
Explore similar products
300KW Central Air Source Heat Pump With Stainless Steel Housing
R410A Air To Water Heating System Spray Coating DHW Heat Pump 300KW
Circulating Heat Industrial Air Source Chiller Heat Pump R407C
480V DHW Heat Pump Air Conditioning HVAC Heating System R407C
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 80000pcs/year |
Delivery Time | 1-30 working days | Packaging Details | standard export package, or as per customer request |
Specificaition | DKFXRS-19II/CY/ air source heat pump water heater | Power | 220V~240V/50Hz/1ph 380V~415V/50Hz/3ph |
Condenser | High efficiency shell and tube heat exchanger | Function | Cooling,Heating,hot water,heating/hot water,DHW |
Refrigerant | R410A,R407C/R410A,R22/R407C,R143a,R407c | Compressor type | Copeland EVI compressor |
Brand Name | LN | Model Number | DKFXRS-38II/CY |
Certification | CE ISO CCC | Place of Origin | China |
High Light | DHW 3 phase air source heat pump ,220V DC Inverter Heat Pump ,3HP DC Inverter Heat Pump |
Features of 3HP Split Air Source Heat Pump DC Inverter
★ DC Inverter Heat Pump, Ambient Temperature Lower to -25°C. The Heating Capacity "NO"
Attenuation even lower to -15°C ; Operation Steadily,COP 30% Higher than Normal heat pump; Meet the needs of Heating, Cooling and Hot Water
★ Designed as Split Type , Indoor Unit and Outdoor Unit Connected by Copper pipe, Installation With Simple, Flexible and Conveniently. The Indoor Unit can be Installed in Kitchen, Bathroom or basement,Ensuring less Energy loss, also Prevent Water Pipes
From Freezing in Cold Winter and sun Exposure in Summer.
★ Indoor Unit Includes:Plate Heat Exchanger, Controller, Water Pump, Differential Pressure Flow Switch, Three Way Valve and so on parts.
★ Outdoor Unit Includes:Compressor, Evaporator, Controller, Expansion Valve, Four way valve, Motor,Refrigerant valve and so on parts.
★ Using DC Inverter Compressor, Green Environment & High-Efficiency, Providing Wonderful
Performance and Reliability.
For further specification of 3HP Split Air Source Heat Pump DC Inverter and other specifications, welcome to contact us!
Unit type | SJKRS-28 II/C | SJKRS-36II/C | SJKRS-55 II/C | SJKRS-73 I/C | SJKRS-106 IC | SJKRS-I60II /C | |
Specifications | 7.5HP | 10HP | 15HP | 20HP | 30HP | 40HP | |
Power supply | Three-phase five-wire380V/50Hz | ||||||
Heating mode | Direct heat/cycle type | ||||||
Standard working condition | Heating capacity( kw ) | 27.5 | 36.7 | 55.1 | 72.8 | 10.6.5 | 155.1 |
Input Power(kW) | 6.1 | 8.2 | 13.7 | 16.1 | 23.6 | 34.5 | |
COP | 4.5 | 4.5 | 4.5 | 4.5 | 4.5 | 4.5 | |
Hot Water flow(m³/h) | 0.59 | 0.79 | 1.18 | 1.56 | 2.29 | 3.33 | |
High temperature condition | Heating capacity kw ) | 23.9 | 28.5 | 51.5 | 59.5 | 89 | 13.1.5 |
Input Power(kW) | 7.5 | 8.9 | 16.1 | 18.6 | 27.8 | 41.1 | |
COP | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 | |
Hot Water flow(m³/h) | 0.27 | 0.33 | 0.59 | 0.68 | 1.02 | 1.51 | |
Low temperature condition | Heating capacity( kw ) | 17.3 | 21.4 | 34.8 | 41.5 | 62.2 | 94.5 |
Input Power(kW) | 6.2 | 7.6 | 12.4 | 14.8 | 22.2 | 33.8 | |
COP | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | |
Hot Water flow(m³/h) | 0.32 | 0.4 | 0.65 | 0.78 | 1.16 | 1.77 | |
Component Information | Size of water pipe joint | DN20 | DN25 | DN32 | DN40 | ||
Water heat exchanger | Plate or sleeve heat exchanger | ||||||
Air Heat Exchanger | Aluminum Fin for copper tube | ||||||
compressor type | Semi-closed reciprocating | ||||||
Operation Panel | Color touch screen | ||||||
Maximum outlet temperature(℃) | 90℃ | ||||||
Refrigerants | R744 (CO2 ) | ||||||
Design pressure(MPa) | High side 15, low side 8 | ||||||
Dimensions (length, width and height mm) | 1450x950x1450 | 1600x950x1500 | 1850x1150x1900 | 2050x1150x1950 | 2670x1410x2150 | 2290x2270x1980 | |
Noise (dB) | 56 | 59 | 62 | 67 | 70 | 70 | |
Weight(kg) | 550 | 660 | 780 | 860 | 1180 | 221360 | |
SCOPE of use | Feed water temperature(℃) | 5~ 40 | |||||
Feed water pressure | 0.05~ 0.4 | ||||||
Effluent temperature(℃) | 55~ 90 | ||||||
Maximum flow | 1.2 | 1.5 | 2.4 | 3.2 | 4.9 | 6.5 | |
Ambient temperature(℃) | ’-20~43 |
3HP Split Air Source Heat Pump DC Inverter
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
2002
Total Annual:
1.MILLION-2MILLION
Employee Number:
50~150
Ecer Certification:
Site Member
As one of the most well-known and respected brands in the ASHP market, our heat pumps are suitable for small retail outlets and commercial buildings as well as domestic properties. Using efficient heat pump technology to deliver supreme comfort and low operating costs, we have different series ... As one of the most well-known and respected brands in the ASHP market, our heat pumps are suitable for small retail outlets and commercial buildings as well as domestic properties. Using efficient heat pump technology to deliver supreme comfort and low operating costs, we have different series ...
Get in touch with us
Leave a Message, we will call you back quickly!