| Color | White |
| Reset Time | less than 1 second |
| Dimensions | Diameter 120mm, Height 40mm |
| Environmental Temperature | -10℃ ~ +55℃ |
| Sensor Type | Photoelectric sensor |
| Item | Photoelectric Sensor Smoke Alarms |
| Led Indicator | Red LED for alarm status |
| Sensitivity | Meets CE standards |
| Power Supply | Battery Operated |
| Operating Voltage | 3V DC |
| Material | ABS fireproof |
| Test Button | Included for manual testing |
| Payment Terms | L/C,T/T,Western Union |
| Supply Ability | 50K/Month |
| Delivery Time | 5 days |
| Packaging Details | Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm |
| Response Time | Within 30 seconds |
| Brand Name | Symank |
| Model Number | JKD-516 |
| Certification | CE/ROHS/SGS/UKCA |
| Place of Origin | China |
View Detail Information
Explore similar products
Wireless Fire Alarm Smoke Detector
EN 14604 Fire Alarm Smoke Detector White 10 Year Lithium Battery Smoke Alarms
White Battery Operated Smoke Alarm 85dB 10 Year Lithium Battery Smoke Detector
EN14604 Certified Fire Alarm Smoke Detector OEM Photoelectric Sensor Fire Alarm
Product Specification
| Color | White | Reset Time | less than 1 second |
| Dimensions | Diameter 120mm, Height 40mm | Environmental Temperature | -10℃ ~ +55℃ |
| Sensor Type | Photoelectric sensor | Item | Photoelectric Sensor Smoke Alarms |
| Led Indicator | Red LED for alarm status | Sensitivity | Meets CE standards |
| Power Supply | Battery Operated | Operating Voltage | 3V DC |
| Material | ABS fireproof | Test Button | Included for manual testing |
| Payment Terms | L/C,T/T,Western Union | Supply Ability | 50K/Month |
| Delivery Time | 5 days | Packaging Details | Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm |
| Response Time | Within 30 seconds | Brand Name | Symank |
| Model Number | JKD-516 | Certification | CE/ROHS/SGS/UKCA |
| Place of Origin | China | ||
| High Light | White Photoelectric Sensor Smoke Alarms ,Photoelectric Sensor Smoke Alarms Fireproof ,Battery Operated Smoke Alarm OEM | ||
Model: JKD-516
The JKD-516 is a standalone photoelectric smoke detector developed for residential fire-warning applications. It operates independently without Wi-Fi, Zigbee, an external gateway or a mobile application, making it suitable for buyers requiring a straightforward battery-powered smoke alarm.
The detector uses two replaceable 1.5V AA batteries and has a stated product life of 10 years from the date of manufacture. Its photoelectric reflection sensor is designed to detect smoke particles, with an alarm sensitivity of 0.25dB/m.
For audible warning, the JKD-516 produces at least 85dB measured at three metres. It can be installed on a ceiling or wall and is intended to cover a room of up to 40m² when installed in accordance with the product manual.
This model is available for OEM, private-label and wholesale smoke detector projects. Certification support includes EN 14604:2005/AC:2008, UKCA and RoHS documentation, together with SGS-issued testing or certification files applicable to the product.
The JKD-516 uses a photoelectric reflection sensor rather than an ionisation chamber. Its specified smoke alarm sensitivity is 0.25dB/m.
This detection principle is commonly selected for residential smoke alarms intended for bedrooms, corridors, living rooms and similar indoor locations.
The detector is powered by two 1.5V AA batteries. The replaceable-battery configuration allows the batteries to be changed without replacing the complete alarm.
Battery operating time depends on battery quality, operating conditions, testing frequency and alarm activity. The 10-year figure refers to the stated product life after manufacture, not to a 10-year sealed battery.
When smoke reaches the alarm threshold, the unit produces a sound level of at least 85dB at three metres. This provides a measurable audible warning specification for residential installation and product-compliance evaluation.
The alarm includes a silence function lasting approximately ten minutes. It allows the user to temporarily reduce the audible warning after confirming that no fire emergency exists.
The alarm should not be permanently disabled, covered or removed as a response to repeated nuisance alarms. Installation position and environmental conditions should be checked instead.
Average standby current is below 50µA, while average alarm current is below 70mA. These electrical values help OEM buyers evaluate battery requirements and expected power consumption.
The JKD-516 is intended for indoor smoke-warning applications in areas such as:
The specified detection range is up to 40m² within one room. Actual product quantity and installation position should be determined according to room layout, local regulations and the installation manual.
The unit operates between -10°C and +50°C at less than 95% relative humidity, non-condensing. It should not be installed in locations where steam, condensation, excessive dust or environmental conditions exceed the stated operating range.
This product is positioned for companies sourcing certified residential smoke alarms rather than for direct consumer retail from the factory.
Typical buyers include:
For buyers managing several markets, product labels, user instructions and packaging can be prepared according to the language and marking requirements confirmed for the order.
The JKD-516 is specified according to EN 14604:2005/AC:2008, the European product standard covering smoke alarm devices for residential applications.
For an importer or distributor, EN 14604 documentation is more useful than a general claim that a product is “European standard.” Relevant files can be reviewed during product evaluation so the buyer can check the model name, product standard and certification scope.
SGS documentation is available for this smoke detector. Buyers should verify that the model reference and applicable standard shown in the supplied report or certificate correspond to the product being ordered.
UKCA documentation is available for projects intended for the United Kingdom. Final label and packaging requirements should be confirmed before mass production.
RoHS documentation supports evaluation of restricted-substance compliance for the electrical and electronic product.
Depending on the order and target market, we can provide applicable copies of:
Certification files should be reviewed against the exact ordered model before approval of the private-label artwork.
Smoke alarm EN14604(CPR) Certi.pdf
| Item | Specification |
|---|---|
| Model | JKD-516 |
| Product type | Standalone smoke detector |
| Product standard | EN 14604:2005/AC:2008 |
| Smoke sensor | Photoelectric reflection |
| Power supply | 2 × 1.5V AA batteries |
| Smoke alarm sensitivity | 0.25dB/m |
| Silence duration | Approximately 10 minutes |
| Product life | 10 years after manufacture |
| Average standby current | <50µA |
| Average alarm current | <70mA |
| Alarm sound level | ≥85dB at 3m |
| Operating temperature | -10°C to +50°C |
| Operating humidity | <95% RH, non-condensing |
| Storage/transport temperature | -10°C to +50°C |
| Storage/transport humidity | <95% RH, non-condensing |
| Installation position | Ceiling or wall |
| Detection range | Maximum 40m² within one room |
| Dimensions | Approximately Φ120 × 39mm |
| Net weight | 180 ±10g |
The JKD-516 can be supplied for OEM and distributor projects with confirmed customization requirements.
Available options may include:
All printed information should be approved before production. Certification markings, standard references and model names must remain consistent with the applicable product documents.
Inspection requirements can be agreed as part of the order specification. Checks may include:
For larger projects, buyers may also arrange pre-shipment inspection according to an agreed sampling standard.
No. It is a standalone smoke detector and does not require an application, gateway or internet connection.
No. It uses two replaceable 1.5V AA batteries. The stated 10 years refers to product life after manufacture.
It is specified according to EN 14604:2005/AC:2008. Buyers should review the relevant certification documents and confirm local marking, registration and packaging requirements.
The specified detection range is up to 40m² within one room. Room shape and local installation requirements may affect the number of alarms needed.
Yes. Product labels, packaging and manuals can be customized subject to order quantity, artwork approval and certification-marking requirements.
Yes. Applicable product specifications and certification documents can be supplied for evaluation before the mass-production order is confirmed.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2012
Total Annual:
1000-1500
Employee Number:
100~150
Ecer Certification:
Verified Supplier
.gtr-container-symank789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; padding: 20px; line-height: 1.6; max-width: 100%; box-sizing: border-box; } .gtr-container-symank789 p { font-size: 14p... .gtr-container-symank789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; padding: 20px; line-height: 1.6; max-width: 100%; box-sizing: border-box; } .gtr-container-symank789 p { font-size: 14p...