China LinkZone Robotic Firefighter Automatic Fire Monitor For Firefighting DC24V
China LinkZone Robotic Firefighter Automatic Fire Monitor For Firefighting DC24V

  1. China LinkZone Robotic Firefighter Automatic Fire Monitor For Firefighting DC24V
  2. China LinkZone Robotic Firefighter Automatic Fire Monitor For Firefighting DC24V

LinkZone Robotic Firefighter Automatic Fire Monitor For Firefighting DC24V

  1. MOQ: 1set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, L/C
Supply Ability 2000sets per month
Delivery Time 5~8 work days
Packaging Details carton box,58.5*46*42cm
Product Name Automatic Fire Monitor
Mode No. ZDMS0.8/20S-LZII
Working Voltage DC 24V
Rated Pressure 0.8Mpa
Protection Radius ≤50m
Rate of flow 20L/s
Installation Height 8~35m
Communication Mode CAN bus
Applicable voltage AC 110V~240V
Rotate Angle Horizontal 360 ° ;vertical 120°
Brand Name LinkZone
Model Number ZDMS0.8/20S-LZII
Certification CCCF
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C Supply Ability 2000sets per month
Delivery Time 5~8 work days Packaging Details carton box,58.5*46*42cm
Product Name Automatic Fire Monitor Mode No. ZDMS0.8/20S-LZII
Working Voltage DC 24V Rated Pressure 0.8Mpa
Protection Radius ≤50m Rate of flow 20L/s
Installation Height 8~35m Communication Mode CAN bus
Applicable voltage AC 110V~240V Rotate Angle Horizontal 360 ° ;vertical 120°
Brand Name LinkZone Model Number ZDMS0.8/20S-LZII
Certification CCCF Place of Origin China
High Light Robotic Firefighter Automatic Fire MonitorAutomatic Fire Monitor For FirefightingDC24V Automatic Fire Monitor Firefighting

LinkZone Robotic Firefighter Automatic Fire Monitor For Firefighting

 

 

Automatic fire monitor 

 

Quick Detail:

●365days uninterrupted video monitoring.

●360° horizontal rotate and 120° vertical rotate.

●High pressure and large range of 360° coverage.

Infrared thermal imaging detecting technology ensure no miss alarming and no fault alarming.

●Applicable voltage range:AC 110V~240V

●Multifunctions:Fire monitoring,Fire alarming and Fire extinguishing.

Energe saving.

Remote control and automatically run.

 

Description:

The automatic fire control wate monitor is widely used in large-space places whose heights are between 6-25m. It applies the micro processor to control the fire monitor.It can probe fire the first time with detection technology of infrared sensing, ultravioletsensing and plasma sensing and put out fire in the bud. This product has high efficient that it can start and stop automatically and repeatedly with quick response.The installing contains pipeline installing and electrical installing.
This is a new auto-scan and positioning fire extinguishing device, which combines function of fire probing and extinguishing. It can probe fire, send alarm signals and adjust direction to aim at fire to put out it automatically. When a fire happens, it adjusts its nozzle
direction and aim at fire after logic analysis of microprocessor. It is of features of timely probing, accurate positioning, concentrate flow jet, auto starting and stopping and big working range.

working principle:

Our automatic fire monitor discharge large volumes of suppression agent from a single fixed location, and at high pressure to give it an excellent range of coverage.The automatic fire water monitor has built-in infrared thermal imaging detector, UV flame detector, closed circuit television camera. Real time dynamic flame location and laser corrector. The automatic fire water monitor works with the external UV flame detector to eliminate the detection blind area and increase early warning range.
When the automatic fire fighting monitor receives the fire early warning signal (UV or IR) signal, the water monitor built-in image IR flame detector will automatically rotate along with the water monitor and lock the flame for 3 seconds, then spray to extinguish the fire. Otherwise, the water monitor will be considered as a false alarm, and the automatic fire monitor will reset automatically.

 

Specifications:

 
  ZDMS0.6/5S-LZII ZDMS0.6/10S-LZII ZDMS0.8/20S-LZII ZDMS0.9/30S-LZII ZDMS0.8/40S-LZII ZDMS0.8/50S-LZII ZDMS1.0/60S-LZII

Working Voltage

DC36V DC36V DC24V DC24V DC24V DC24V DC24V
Rated Pressure 0.6MPa 0.6MPa 0.8MPa 0.9MPa 0.8MPa 0.8MPa 1.0MPa
Protection Radius ≤30m 35m 50m 55m 60m 65m 70m
Rate of flow 5L/s 10L/s 20L/s 30L/s 40L/s 50L/s 60L/s
Installation Height 6~15m 6~15m 8~35m 8~35m 8~35m 8~35m 8~35m
Jet radius 34m 39m 56m 62m 67m 73m 78m
Positioning time ≤30s ≤30s ≤60s ≤60s ≤60s ≤60s ≤60s
Monitoring radius 40m 40m 60m 60m 80m 80m 80m
Flange Connection DN50 DN50 DN80 DN80 DN100 DN100 DN100

 

Notices:

1.The side of automatic fire monitor with label”this side to wall” must be faced to wall when installed.
2.Video line connected from DVR to cannon directly.
3.Signal lines must connect to signal lines of cannon where it is 2m from cannon.
4.Operation panel installed near the exit and 1.5m from ground,and from where operator can see all cannnons controlled by this operation panel.
5.Pls take care when handling cannon as there is UV detector at the bottom of cannon.The UV detetor is fragile.
6.Make sure there is no barrier around the cannon to stop the cannon 360 degree rotate.
7.The ground lead of DVR,earth wire and Lightning protection wire of control console need be connected to your ground lead.

 

Applications:

Our automatic fire monitor are wildly used in Industrial,commercial and residential fields.Such as airport, high-speed railway station, bus station, hotel atrium, museum, library, TV studio, gymnasium, science and technology museum, exhibition hall, convention center, theater, cinema, civic activity center, industrial plant, chemical plant, gas station, oil port,helicopter hangar, power plants, logistics centers, hospitals, large shopping malls, commercial complexes, colleges and universities, coal mines, warehouses and other places with large space.

FAQ:

Q1: Are you a manufacturer?

A1: Yes. We are a professional manufacture of automatic fire water monitor which has the most advanced technology.
Q2: What certificates do you have?
A2: We have CCCF and ISO certificates at present. All products tested by CHINA National Fire Equipment Quality Inspection and testing Center
Q3: What are the advantages of your Automatic Fire Monitor?
A3: Our Automatic Fire Monitor adopt the most advanced Infrared thermal imaging detecting and tracking technology. Our Fire Water Cannon integrates the following functions: 1. Remote Video Surveillance. 2. Fire Alarm. 3. Automatically Fire Extinguishing.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    10000000-20000000

  • Employee Number:

    101~200

  • Ecer Certification:

    Verified Supplier

We are a National Standard high-tech firefighting equipment manufacturing Enterprise from China and we do technology researching,structural designing,production, sales and service all by ourself.We have the most advanced technology for automatic fire targeting technology.We are the member of Ch... We are a National Standard high-tech firefighting equipment manufacturing Enterprise from China and we do technology researching,structural designing,production, sales and service all by ourself.We have the most advanced technology for automatic fire targeting technology.We are the member of Ch...

+ Read More

Get in touch with us

  • Reach Us
  • Henan LinkZone Fire Technology Co.,Ltd
  • Room 602,Building 6,No.316,lianhua street,High-tech zone,Zhengzhou,China
  • Alex Zhang
  • +86 19836717667
  • https://www.automaticfiremonitor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement