China factories

Chat Now Send Email
China factory - JULUN (H.K)CO.,LTD (DONGGUAN JULUN ELECTRONICS CO.,LTD)

JULUN (H.K)CO.,LTD (DONGGUAN JULUN ELECTRONICS CO.,LTD)

  • China,Dongguan ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China PA66 Housing Automotive Blade Fuses ISO 8820-3
China PA66 Housing Automotive Blade Fuses ISO 8820-3

  1. China PA66 Housing Automotive Blade Fuses ISO 8820-3

PA66 Housing Automotive Blade Fuses ISO 8820-3

  1. MOQ: 100 / Negotiable
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/P, T/T,
Supply Ability 10000/Piece/Weekly
Delivery Time 7~10 Working days
Packaging Details Standard carton
Voltage Rating 32 VDC
Interrupting Ratings 1000A @ 32 VDC
Component Level Temperature Range -40˚C To +105˚C
System Level Temperature Range -40˚C To +85˚C
TerminaHousing Materialls Sn Plated Zinc Alloy
Housing Material PA66
Complies With SAE J1284,ISO 8820-3
UL Listed File AU1410
CSA Certified File No. 29862
Brand Name Julun
Model Number 0287
Certification CE/UL/VDE/KC/ROHS
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/P, T/T, Supply Ability 10000/Piece/Weekly
Delivery Time 7~10 Working days Packaging Details Standard carton
Voltage Rating 32 VDC Interrupting Ratings 1000A @ 32 VDC
Component Level Temperature Range -40˚C To +105˚C System Level Temperature Range -40˚C To +85˚C
TerminaHousing Materialls Sn Plated Zinc Alloy Housing Material PA66
Complies With SAE J1284,ISO 8820-3 UL Listed File AU1410
CSA Certified File No. 29862 Brand Name Julun
Model Number 0287 Certification CE/UL/VDE/KC/ROHS
Place of Origin CHINA
High Light PA66 Housing Automotive Blade FusesAutomotive Blade Fuses ISO 8820-3

Operation Temperature: -40℃ - 80℃ Automotive Blade Fuse

 

ATOF_Datasheet.pdf

 

Electrical Performances

 

Ampere Rating(A) Part Number Housing Colors Resistance Value Voltage Drop
5A 1173 Tan 17.3 mΩ 117 mV
7.5A 1174 Brown 10.7 mΩ 109 mV
10A 1175 Red 7.85 mΩ 104 mV
15A 1176 Blue 5.05 mΩ 100 mV
20A 1177 Yellow 3.65 mΩ 95 mV
25A 1178 White(natural) 2.75 mΩ 88 mV
30A 1179 Green 2.18 mΩ 82 mV



 

Time-Current Characteristics

 

 

% of Ampere Rating(A) Operating Time
MIN MAX
110% 100 hrs. -
135% 0.75 sec. 120 sec.
160% 0.25 sec. 50 sec.
200% 0.15 sec. 5 sec.
350% 0.04 sec. 0.5 sec.
600% 0.02 sec. 0.1 sec.


 

Features


Suitable sizes : 5, 7.5, 10 and 15 Amp.
Voltage Rating: 32 VDC.
Interrupting Ratings: 1000A @ 32 VDC.
Operating Temperature: -40°C to 125°C.
Terminals: Ag Plated Zinc Alloy.
Housing Material: PA66.
RoHS.

Sub-miniature design

New standard for vehicle circuit protection

Space saving - smaller than the MINI® fuse

 

How to change a fuse on a plug socket ?

 

For a standard plug you will need a screwdriver (usually a flat headed screwdriver but will depend on the screws in that particular plug – take a look at the base).

 

1) In an anti-clockwise direction, loosen the screw(s) – typically this type of plug will have a larger central screw that holds the cases halves together; that’s the one to go for. You may not need to remove all the screws completely as the back of the plug should come away following a few turns of the screws.
2)Open the case and keep the back and the screw in a safe place for reinstating later.
3)Pull the fuse out, you will find the fuse within two metal holders inside the plug, sometimes these can be tight and need to be prised out, don’t worry if one of the pins lifts out with it initially – this just slides back through the case once the fuse is removed.
4)Replace the old fuse with a new fuse (making sure it’s like for like or that you really understand why it’s changing if it is).
5)It’s often worth just checking the terminals (the small screws that hold the cables in the plug) are tight at this point – a loose connection can cause overheating and an increase in current which may be why the fuse blew initially). Just try to tighten them with (usually) a small flat blade screwdriver to make sure they are nice and tight.
6)Return the lid of the plug and screw firmly. When secure there should be no movement from the metal pins that go into the wall socket.
7)If the fuse blows again, there may be an electrical fault not associated with the fuse. In this instance, we would recommend an electrician to carry out an electrical safety inspection to check the product.


 
Description
 

Developed by UCHI for the automotive industry, MEDIUM AUTO BLADE fuse has become the original equipment circuit protection standard for foreign and domestic automobiles and trucks. Readily identifiable and easily replaced, this fuse can be specified for a variety of low voltage electronic applications.

 

Application
 
-Machine
-Vehicle

 

Specification

 

Tin Plated Silver Plated
Voltage Rating 32 VDC 32 VDC
Interrupting Rating 1000A @ 32 VDC 1000A @ 32 VDC
Component Level Temperature Range -40˚C to +105˚C -40˚C to +125˚C
System Level Temperature Range -40˚C to +85˚C -40˚C to +105˚C
Terminals Sn plated zinc alloy Ag plated zinc alloy
Housing Material PA66 PA66
Complies with SAE J1284,ISO 8820-3 SAE J1284,ISO 8820-3
UL Listed File AU1410 File AU1410
CSA Certified File No. 29862 File No. 29862


**105°C and 85°C are typical system level temperature requirements.
 

Ratings

 

Part Number Current Rating
(A)
Typ. Voltage Drop
(mV)
Cold Resistance
(mΩ)
I2t
(A2s)
0287001._ 1 176 123 0.4
0287002._ 2 141 53.5 1.4
0287003._ 3 137 31.1 7.4
0287004._ 4 136 22.8 14
0287005._ 5 128 17.85 26
028707.5_ 7.5 116 10.91 60
0287010._ 10 109 7.70 115
0287015._ 15 102 4.80 340
0287020._ 20 98 3.38 520
0287025._ 25 92 2.52 1080
0287030._ 30 84 1.97 1510
0287035._ 35 87 1.61 2280
0287040._ 40 96 1.44 3310

 

Time-Current Characteristics

 

% of Rating Current
Rating
Opening Time
Min / Max (s)
100 35A & 40A 360,000 s / –
110 1A-30A 360,000 s / –
135 1A & 2A
3A-40A
350 ms / 600 s
0.750 s / 600 s
160 1A-40A 250 ms / 50 s
200 1A & 2A
3A-40A
100 ms / 5.0 s
0.150 s / 5.0 s
350 1A & 2A
3A-40A
20 ms / 500 ms
80 ms / 500 ms
600 1A-30A
35A & 40A
– / 100 ms
– / 150 ms

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler

  • Year Established:

    2009

  • Total Annual:

    5900000-7000000

  • Ecer Certification:

    Verified Supplier

    JULUN (H.K)CO.,LTD DONGGUAN JULUN ELECTRONICS has a focus on circuit protection R & D, production and sales of enterprises, products are widely used in new energy photovoltaic, electric vehicles, batteries, electricity, energy storage, environmental protection sy...     JULUN (H.K)CO.,LTD DONGGUAN JULUN ELECTRONICS has a focus on circuit protection R & D, production and sales of enterprises, products are widely used in new energy photovoltaic, electric vehicles, batteries, electricity, energy storage, environmental protection sy...

+ Read More

Get in touch with us

  • Reach Us
  • JULUN (H.K)CO.,LTD (DONGGUAN JULUN ELECTRONICS CO.,LTD)
  • Room 408 No:262 middle West Lake Road, Shilong Town, Dongguan City ,Guangdong Province, China
  • https://www.automotive-fuses.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement