| Payment Terms | T/T, L/C |
| Supply Ability | 10 set /month |
| Delivery Time | 30 days |
| Packaging Details | Plywood |
| Product name | Apparatus for testing cord retention |
| Working station | one, two stations option |
| test time | 0-9999, preset |
| Standard | IEC 60884-1 |
| Test weights | 10N*1, 60N*1, 20N*2 |
| Pull applied time | 1s |
| Brand Name | HeJin |
| Model Number | HC9917 |
| Certification | calibration certificate (cost additional) |
| Place of Origin | China |
View Detail Information
Explore similar products
PLC Control System Switch Plug Socket Endurance Tester for Plug Socket Test
HC9932 304 Stainless Steel Compression Tester with 20 N Force for Plug Socket
IEC 60811-1-4 Compliant Low Temperature Impact Test Apparatus with 100 mm Drop
3 Station Plug Socket Test Equipment IEC60884-1 And IEC61058-1
Product Specification
| Payment Terms | T/T, L/C | Supply Ability | 10 set /month |
| Delivery Time | 30 days | Packaging Details | Plywood |
| Product name | Apparatus for testing cord retention | Working station | one, two stations option |
| test time | 0-9999, preset | Standard | IEC 60884-1 |
| Test weights | 10N*1, 60N*1, 20N*2 | Pull applied time | 1s |
| Brand Name | HeJin | Model Number | HC9917 |
| Certification | calibration certificate (cost additional) | Place of Origin | China |
| High Light | Two Stations Plug Socket Test Equipment ,Cord Retention Plug Socket Test Equipment | ||
Plug Socket Test Equipment For Testing Cord Retention 60 Times/Min
Standard of Apparatus for testing cord retention:
IEC 60884-1 ‘Plugs and socket-outlets for household and similar purposes – Part 1: General requirements’ clause 23.2 and figure 20.
Application of Apparatus for testing cord retention:
Rewirable plugs and rewirable portable socket-outlets shall be provided with a cord anchorage such that the conductors are relieved from strain, including twisting, where they are connected to the terminals and that their covering is protected from abrasion.
Apparatus for testing cord retention is used to check the effectiveness of the retention of the cable by the cord anchorage.
Parameter of Apparatus for testing cord retention:
| Power supply | AC 220V 50Hz |
| Test weights | 10N*1, 60N*1, 20N*2 |
| Rate of testing | 60 times / min |
| Test times | 0-9999, preset. Default 100 times. |
| Pull |
– 50 N if the rated current is 2,5 A, – 60 N if the rated current is above 2,5 A, but not more than 16 A and the rated voltage is up to and including 250 V, – 80 N if the rated current is above 2,5 A, but not more than 16 A and the rated voltage is above 250 V, – 100 N if the rated current greater than 16 A. |
| Pull applied time | 1s without jerks |
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2012
Total Annual:
3000000-5000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
.gtr-container-hejin-12345 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 100%; box-sizing: border-box; overflow-x: hidden; } .gtr-container-hejin-... .gtr-container-hejin-12345 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 100%; box-sizing: border-box; overflow-x: hidden; } .gtr-container-hejin-...
Get in touch with us
Leave a Message, we will call you back quickly!