| Payment Terms | T/T, L/C |
| Supply Ability | 20 set /month |
| Delivery Time | 30 days |
| Packaging Details | Carton Box |
| Product name | Screwless Terminals Thermal Stress Tester HC9904 |
| Test sample | Screwless Terminals |
| Standard | IEC 60884-1 |
| Test current | AC 1~99.9A±(3%±1A) |
| Power supply | AC220V 5A 50HZ |
| Voltage drop measurement | 0~199.9±(3%±1mv) |
| Brand Name | HeJin |
| Model Number | HC9904 |
| Certification | calibration certificate (cost additional) |
| Place of Origin | China |
View Detail Information
Explore similar products
PLC Control System Switch Plug Socket Endurance Tester for Plug Socket Test
HC9932 304 Stainless Steel Compression Tester with 20 N Force for Plug Socket
IEC 60811-1-4 Compliant Low Temperature Impact Test Apparatus with 100 mm Drop
3 Station Plug Socket Test Equipment IEC60884-1 And IEC61058-1
Product Specification
| Payment Terms | T/T, L/C | Supply Ability | 20 set /month |
| Delivery Time | 30 days | Packaging Details | Carton Box |
| Product name | Screwless Terminals Thermal Stress Tester HC9904 | Test sample | Screwless Terminals |
| Standard | IEC 60884-1 | Test current | AC 1~99.9A±(3%±1A) |
| Power supply | AC220V 5A 50HZ | Voltage drop measurement | 0~199.9±(3%±1mv) |
| Brand Name | HeJin | Model Number | HC9904 |
| Certification | calibration certificate (cost additional) | Place of Origin | China |
| High Light | Screwless Terminals Thermal Stress Tester ,AC220V Plug Socket Test Equipment ,AC220V Screwless Terminals Test Equipment | ||
Plug Socket Test Equipment Screwless Terminals Thermal Stress Tester IEC 60884-1
Standard:
IEC 60884-1 2013 ‘Plugs and socket-outlets for household and similar purposes -- Part 1: General requirements’ clause 12.3.11
Application:
Screwless terminals shall withstand the electrical and thermal stresses occurring in normal use.
This device is use to check whether the screwless terminals can withstand the electrical and thermal stresses occurring in normal use. Plug Socket Test Equipment
Test sample:
Screwless Terminals. Plug Socket Test Equipment
Feature:
Loading the screwless terminals for 1 h with an alternating current as specified in table 10 and connecting rigid solid conductors 1 m long having the nominal cross-sectional area as specified in the same table. Then measure the voltage drop.
Table 10- Test current for the verification of electrical and thermal stresses in normal use for screwless terminals
|
Rated current A |
Test current A |
Nominal cross-sectional area of the conductor mm2 |
|
10 and 13 16 |
17.5 22 |
1.5 2.5 |
| NOTE For socket-outlets having rated currents lower than 10 A, the test current is proportionally determined and the cross-sectional area of the conductors is 1.5 mm 2 . | ||
Parameters:
| Test cycles | 192 cycles, current flow for 30min, no current flow for 30min |
| Power supply | AC220V 5A 50HZ |
| Test current | AC 1~99.9A±(3%±1A) |
| Voltage drop measurement | 0~199.9±(3%±1mv) |
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2012
Total Annual:
3000000-5000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
.gtr-container-hejin-12345 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 100%; box-sizing: border-box; overflow-x: hidden; } .gtr-container-hejin-... .gtr-container-hejin-12345 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 100%; box-sizing: border-box; overflow-x: hidden; } .gtr-container-hejin-...
Get in touch with us
Leave a Message, we will call you back quickly!