China factories

Chat Now Send Email
China factory - HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

  • China,Guangzhou ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Cold Plate Helium Leak Testing Machine for Liquid Cooling Plates | High
China Cold Plate Helium Leak Testing Machine for Liquid Cooling Plates | High

  1. China Cold Plate Helium Leak Testing Machine for Liquid Cooling Plates | High
  2. China Cold Plate Helium Leak Testing Machine for Liquid Cooling Plates | High
  3. China Cold Plate Helium Leak Testing Machine for Liquid Cooling Plates | High
  4. China Cold Plate Helium Leak Testing Machine for Liquid Cooling Plates | High

Cold Plate Helium Leak Testing Machine for Liquid Cooling Plates | High

  1. MOQ: 1 Set
  2. Price: Negotiatable
  3. Get Latest Price
Helium Concentration Adjustable 50%-96%
Payment Terms L/C,T/T,D/P
Production Cycle Time 180s/PCS
Filling Pressure 0-4 MPa
Power Supply 380V
Supply Ability 1 sets per 3 month
Helium Recovery Efficiency >95%
Delivery Time 75 working days
Leak Alarm Rate <1*10⁻⁶ mbar·L/s
Packaging Details Plywood
Noise Level ≤75 dB
Equipment Weight 5000 KG
Model Number HJ165-2
Brand Name HeJin
Place of Origin China
Certification Third party calibration certificate/ CE(cost additional)

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Helium Concentration Adjustable 50%-96% Payment Terms L/C,T/T,D/P
Production Cycle Time 180s/PCS Filling Pressure 0-4 MPa
Power Supply 380V Supply Ability 1 sets per 3 month
Helium Recovery Efficiency >95% Delivery Time 75 working days
Leak Alarm Rate <1*10⁻⁶ mbar·L/s Packaging Details Plywood
Noise Level ≤75 dB Equipment Weight 5000 KG
Model Number HJ165-2 Brand Name HeJin
Place of Origin China Certification Third party calibration certificate/ CE(cost additional)
High Light helium leak testing machine for liquid cooling plateshigh precision helium leak testing equipmenthelium leak testing machine with helium recovery

Cold Plate Helium Leak Testing Machine for Liquid Cooling Plates | High Precision Helium Leak Testing Equipment with 95% Helium Recovery

Product Brief Description

The Cold Plate Helium Leak Testing Machine is a high-precision helium leak testing equipment developed and manufactured by HeJin for liquid cooling plate manufacturers and thermal management component suppliers. Designed for demanding production environments, the system combines vacuum chamber leak testing, helium recovery technology, and intelligent pressure control to deliver reliable and repeatable leak detection performance.

With helium concentration adjustment from 50% to 96%, leak rate sensitivity below 1*10⁻⁶ mbar·L/s, and helium recovery efficiency exceeding 95%, it significantly reduces operating costs while improving production efficiency. The machine is ideal for EV battery cooling plates, liquid cooling systems, and various sealed thermal management components.

Product Introduction

In industries where sealing performance directly impacts product reliability, even microscopic leakage can lead to reduced thermal efficiency, fluid contamination, or shortened service life.

The HeJin Cold Plate Helium Leak Testing Machine is engineered to address these challenges. Developed by our in-house R&D team, the equipment provides fully automated leak detection solutions for cold plates and precision thermal management components.

From customized fixtures and vacuum chamber design to helium recovery systems and intelligent control algorithms, every detail is optimized to meet modern manufacturing requirements.

Product Functions

  • Helium leak testing
  • Vacuum chamber leak detection
  • Automatic pressure control
  • Helium concentration adjustment
  • Helium gas recovery
  • Production data management
  • Customized fixture positioning
  • Leak alarm system
  • Automatic loading and unloading

International Reference Standards

Standard Description
ISO 20485 Non-destructive testing - Leak testing principles
ASTM E493 Standard Test Methods for Leaks Using Mass Spectrometer Leak Detectors
ASTM E498 Helium Leak Detection Procedures
ASTM E499 Vacuum Leak Testing Methods
ISO 9712 Qualification of NDT personnel
ISO 9001 Quality management requirements

Applications

  • Battery liquid cooling plates
  • EV thermal management components
  • Aluminum cold plates
  • Refrigerant cooling plates
  • Heat exchangers
  • Liquid cooling modules
  • Cooling pipelines
  • Automotive thermal management assemblies

Technical Parameters

Item Parameter
Model HJ165-2
Product Type Cold Plate Helium Leak Testing Machine
Housing Material Sheet Metal Structure
Color RAL7035 (Customizable)
Leak Testing Range According to selected leak detector
Helium Concentration Adjustable 50%-96%
Leak Alarm Rate <1*10⁻⁶ mbar·L/s
Loading Method Roller Conveyor Loading & Unloading
Vacuum Chamber Quantity 1 Set
Vacuum Chamber Size Customized according to workpiece
Filling Pressure 0-4 MPa
Production Cycle Time 180s/PCS
OEE >98%
Fixture Type Customized
Helium Recovery Efficiency >95%
Sniffer Leak Detection Optional Configuration
Noise Level ≤75 dB
CMK >1.67
Equipment Weight 5000 KG
Power Supply 380V

Core Technologies

The HJ165-2 adopts:

  • Vacuum Chamber Leak Detection Technology

    Provides stable and repeatable vacuum testing conditions.

  • Helium Recovery Technology

    Helium recovery efficiency exceeds 95%, greatly reducing production costs.

  • Intelligent Pressure Control Technology

    Supports:

    • 0~4 MPa filling pressure
    • Stable pressure holding
    • Automated pressure monitoring
  • Customized Fixture Technology

    Suitable for different cold plate structures and dimensions.

Detailed images

Why Choose HeJin?

HeJin Ordinary Suppliers
Source Manufacturer Trading Company
In-house R&D Outsourcing Design
Customized Fixtures Limited Customization
Helium Recovery Technology Optional or None
Complete After-sales Service Limited Support
Factory Direct Supply Multiple Supply Chains
Global Technical Support Basic Service
High OEE Production Design Conventional Design

FAQ

Q1. What is the minimum detectable leak rate?

The machine supports leak rates below 1*10⁻⁶ mbar·L/s.

Q2. Can the machine be customized?

Yes. Fixture design, vacuum chamber size and software functions can be customized.

Q3. Does the system support helium recovery?

Yes. The helium recovery rate is higher than 95%.

Q4. What industries can use this machine?

It is widely used in:

  • EV battery manufacturing
  • Thermal management systems
  • Energy storage systems
  • Automotive component manufacturing

Q5. Is automation available?

Yes. Roller conveyor loading and unloading supports automated production line integration.

Q6. How long is one testing cycle?

Approximately 180 seconds per workpiece.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2012

  • Total Annual:

    3000000-5000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

.gtr-container-hejin-12345 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 100%; box-sizing: border-box; overflow-x: hidden; } .gtr-container-hejin-... .gtr-container-hejin-12345 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 100%; box-sizing: border-box; overflow-x: hidden; } .gtr-container-hejin-...

+ Read More

Get in touch with us

  • Reach Us
  • HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
  • No.6-36, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou, Guangdong, China
  • https://www.autoparts-test.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement