| Number of Channels | 32 Channels |
| Delivery Time | 15-30 working days after deposit |
| Model | XW-5V100A32CH |
| Equipment Type | Battery Formation and Capacity Grading Machine |
| Working Environment | Temperature 0-40°C, Relative Humidity ≤80% |
| Process Setting | Up to 32 Steps and 256 Cycles |
| Working Power | ≤23kW |
| Time Range | 0-3000 Minutes |
| Sampling Inspection Cycle | 1-60s |
| Payment Terms | T/T, L/C, Western Union |
| Current Accuracy | ±(0.5‰ Reading + 0.5‰ Full Scale) |
| Battery Type | Prismatic Cell |
| Charge / Discharge Current | 5V 100A |
| Control Mode | Software-installed Computer, Whole Cabinet Control |
| Charging Mode | Constant Current / Voltage / Current & Voltage |
| Discharge Mode | Constant Current / Power / Resistance |
| Time Accuracy | ≤ ±1‰ |
| Equipment Size (L x W x H) | 900 x 950 x 1840mm |
| Fixture Distance | 112mm |
| Voltage Resolution | 0.1mV |
| Constant Voltage Range | 2.0-4.5V |
| Communication Method | RS485, Baudrate 57600 |
| Support P/N Distance | 40-300mm |
| Working Power Supply | 3-phase 5-wire AC380V ±10%, 50Hz |
| Cooling Method | Natural Air Intake, Upward Exhaust |
| Support Battery Thickness | 16-103mm |
| Support Battery Length | 65-370mm |
| Voltage Measurement Range | 0-5V |
| Packaging Details | Plywood case with shock-proof foam, export-grade packaging |
| Charging Cut-off Conditions | Voltage / Current / Time / Capacity |
| Fixture Form | Four-wire Method Fixture |
| Voltage Accuracy | ±(0.5‰ Reading + 0.5‰ Full Scale) |
| Data Processing | Record Voltage/Current/Time/Capacity; Auto-calculate Current Ratio, Capacity Loss, Discharge Efficiency, Average & Median Voltage; Graphs; Text/EXCEL/WORD/MDB Export |
| Battery Grading | By Capacity, Time, Open Circuit Voltage, Discharge Platform |
| Supply Ability | 200 Sets per Month |
| Support Battery Height | 90-250mm |
| Discharge Cut-off Conditions | Voltage / Time / Capacity |
| Protection Function | Over/Under Voltage, Over/Under Current, Over Capacity, Power Failure Protection, Data Breakpoint Recovery |
| Model Number | XW-5V100A32CH |
| Place of Origin | Guangdong, China |
| Brand Name | XWELL |
| Certification | CE, ISO 9001:2015 |
View Detail Information
Explore similar products
8 Channel Battery Cell Grading Machine For Coin Cell Pouch Cell Cylindrical
5V Battery Cell Grading Machine , 57600 Cylindrical Coin Cell Battery Tester
Battery Forming And Grading Machine Equipment Capacity Tester Analyzer
5V 100A 64 Channel Prismatic Cell Battery Tester Grading Testing Machine
Product Specification
| Number of Channels | 32 Channels | Delivery Time | 15-30 working days after deposit |
| Model | XW-5V100A32CH | Equipment Type | Battery Formation and Capacity Grading Machine |
| Working Environment | Temperature 0-40°C, Relative Humidity ≤80% | Process Setting | Up to 32 Steps and 256 Cycles |
| Working Power | ≤23kW | Time Range | 0-3000 Minutes |
| Sampling Inspection Cycle | 1-60s | Payment Terms | T/T, L/C, Western Union |
| Current Accuracy | ±(0.5‰ Reading + 0.5‰ Full Scale) | Battery Type | Prismatic Cell |
| Charge / Discharge Current | 5V 100A | Control Mode | Software-installed Computer, Whole Cabinet Control |
| Charging Mode | Constant Current / Voltage / Current & Voltage | Discharge Mode | Constant Current / Power / Resistance |
| Time Accuracy | ≤ ±1‰ | Equipment Size (L x W x H) | 900 x 950 x 1840mm |
| Fixture Distance | 112mm | Voltage Resolution | 0.1mV |
| Constant Voltage Range | 2.0-4.5V | Communication Method | RS485, Baudrate 57600 |
| Support P/N Distance | 40-300mm | Working Power Supply | 3-phase 5-wire AC380V ±10%, 50Hz |
| Cooling Method | Natural Air Intake, Upward Exhaust | Support Battery Thickness | 16-103mm |
| Support Battery Length | 65-370mm | Voltage Measurement Range | 0-5V |
| Packaging Details | Plywood case with shock-proof foam, export-grade packaging | Charging Cut-off Conditions | Voltage / Current / Time / Capacity |
| Fixture Form | Four-wire Method Fixture | Voltage Accuracy | ±(0.5‰ Reading + 0.5‰ Full Scale) |
| Data Processing | Record Voltage/Current/Time/Capacity; Auto-calculate Current Ratio, Capacity Loss, Discharge Efficiency, Average & Median Voltage; Graphs; Text/EXCEL/WORD/MDB Export | Battery Grading | By Capacity, Time, Open Circuit Voltage, Discharge Platform |
| Supply Ability | 200 Sets per Month | Support Battery Height | 90-250mm |
| Discharge Cut-off Conditions | Voltage / Time / Capacity | Protection Function | Over/Under Voltage, Over/Under Current, Over Capacity, Power Failure Protection, Data Breakpoint Recovery |
| Model Number | XW-5V100A32CH | Place of Origin | Guangdong, China |
| Brand Name | XWELL | Certification | CE, ISO 9001:2015 |
| High Light | High precision prismatic battery grading machine ,Battery formation and capacity grading machine ,XWELL prismatic battery testing machine | ||
The XW-5V100A32CH offers high precision measurement with a 0-5V range, 0.1mV resolution and 0.5 per mille accuracy for both voltage and current. Its four-wire method fixture minimizes contact resistance for reliable grading results.
| Model | XW-5V100A32CH |
| Equipment Type | Battery Formation and Capacity Grading Machine |
| Number of Channels | 32 Channels |
| Battery Type | Prismatic Cell |
| Equipment Size (L x W x H) | 900 x 950 x 1840mm |
| Fixture Form | Four-wire Method Fixture |
| Fixture Distance | 112mm |
| Support Battery Length | 65-370mm |
| Support Battery Thickness | 16-103mm |
| Support Battery Height | 90-250mm |
| Support P/N Distance | 40-300mm |
| Working Power Supply | 3-phase 5-wire AC380V ±10%, 50Hz |
| Working Power | ≤23kW |
| Working Environment | Temperature 0-40°C, Relative Humidity ≤80% |
| Cooling Method | Natural Air Intake, Upward Exhaust |
| Voltage Measurement Range | 0-5V |
| Voltage Resolution | 0.1mV |
| Constant Voltage Range | 2.0-4.5V |
| Voltage Accuracy | ±(0.5‰ Reading + 0.5‰ Full Scale) |
| Current Accuracy | ±(0.5‰ Reading + 0.5‰ Full Scale) |
| Charge / Discharge Current | 5V 100A |
| Control Mode | Software-installed Computer, Whole Cabinet Control |
| Communication Method | RS485, Baudrate 57600 |
| Process Setting | Up to 32 Steps and 256 Cycles |
| Charging Mode | Constant Current / Voltage / Current & Voltage |
| Charging Cut-off Conditions | Voltage / Current / Time / Capacity |
| Discharge Mode | Constant Current / Power / Resistance |
| Discharge Cut-off Conditions | Voltage / Time / Capacity |
| Protection Function | Over/Under Voltage, Over/Under Current, Over Capacity, Power Failure Protection, Data Breakpoint Recovery |
| Time Range | 0-3000 Minutes |
| Time Accuracy | ≤ ±1‰ |
| Sampling Inspection Cycle | 1-60s |
| Battery Grading | By Capacity, Time, Open Circuit Voltage, Discharge Platform |
| Data Processing | Record Voltage/Current/Time/Capacity; Auto-calculate Current Ratio, Capacity Loss, Discharge Efficiency, Average & Median Voltage; Graphs; Text/EXCEL/WORD/MDB Export |
XWELL XW-5V100A32CH prismatic battery formation and capacity grading machine, engineered for accurate and efficient battery production.
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
2016
Total Annual:
3000000-5000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
GUANGDONG XWELL TECHNOLOGY CO., LTD. is a high-tech enterprise specializing in intelligent equipment design, production and sales, providing mechanical engineering technology design and consulting services, electronic engineering design and consulting services. XWELL's core team was established ... GUANGDONG XWELL TECHNOLOGY CO., LTD. is a high-tech enterprise specializing in intelligent equipment design, production and sales, providing mechanical engineering technology design and consulting services, electronic engineering design and consulting services. XWELL's core team was established ...
Get in touch with us
Leave a Message, we will call you back quickly!