| Support Battery Thickness | 16-103mm |
| Voltage Accuracy | ±(0.5‰ Reading + 0.5‰ Full Scale) |
| Payment Terms | T/T, L/C, Western Union |
| Number of Channels | 32 Channels |
| Working Power Supply | 3-phase 5-wire AC380V ±10%, 50Hz |
| Working Environment | Temperature 0-40°C, Relative Humidity ≤80% |
| Support P/N Distance | 40-300mm |
| Charging Cut-off Conditions | Voltage / Current / Time / Capacity |
| Protection Function | Over/Under Voltage, Over/Under Current, Over Capacity, Power Failure Protection, Data Breakpoint Recovery |
| Model | XW-5V100A32CH |
| Support Battery Length | 65-370mm |
| Delivery Time | 15-30 working days after deposit |
| Time Range | 0-3000 Minutes |
| Support Battery Height | 90-250mm |
| Charge / Discharge Current | 5V 100A |
| Control Mode | Software-installed Computer, Whole Cabinet Control |
| Battery Type | Prismatic Cell |
| Fixture Form | Four-wire Method Fixture |
| Voltage Measurement Range | 0-5V |
| Communication Method | RS485, Baudrate 57600 |
| Process Setting | Up to 32 Steps and 256 Cycles |
| Discharge Cut-off Conditions | Voltage / Time / Capacity |
| Voltage Resolution | 0.1mV |
| Time Accuracy | ≤ ±1‰ |
| Supply Ability | 200 Sets per Month |
| Fixture Distance | 112mm |
| Working Power | ≤23kW |
| Data Processing | Record Voltage/Current/Time/Capacity; Auto-calculate Current Ratio, Capacity Loss, Discharge Efficiency, Average & Median Voltage; Graphs; Text/EXCEL/WORD/MDB Export |
| Constant Voltage Range | 2.0-4.5V |
| Current Accuracy | ±(0.5‰ Reading + 0.5‰ Full Scale) |
| Discharge Mode | Constant Current / Power / Resistance |
| Packaging Details | Plywood case with shock-proof foam, export-grade packaging |
| Battery Grading | By Capacity, Time, Open Circuit Voltage, Discharge Platform |
| Equipment Type | Battery Formation and Capacity Grading Machine |
| Charging Mode | Constant Current / Voltage / Current & Voltage |
| Sampling Inspection Cycle | 1-60s |
| Equipment Size (L x W x H) | 900 x 950 x 1840mm |
| Cooling Method | Natural Air Intake, Upward Exhaust |
| Brand Name | XWELL |
| Model Number | XW-5V100A32CH |
| Certification | CE, ISO 9001:2015 |
| Place of Origin | Guangdong, China |
View Detail Information
Explore similar products
8 Channel Battery Cell Grading Machine For Coin Cell Pouch Cell Cylindrical
5V Battery Cell Grading Machine , 57600 Cylindrical Coin Cell Battery Tester
Battery Forming And Grading Machine Equipment Capacity Tester Analyzer
5V 100A 64 Channel Prismatic Cell Battery Tester Grading Testing Machine
Product Specification
| Support Battery Thickness | 16-103mm | Voltage Accuracy | ±(0.5‰ Reading + 0.5‰ Full Scale) |
| Payment Terms | T/T, L/C, Western Union | Number of Channels | 32 Channels |
| Working Power Supply | 3-phase 5-wire AC380V ±10%, 50Hz | Working Environment | Temperature 0-40°C, Relative Humidity ≤80% |
| Support P/N Distance | 40-300mm | Charging Cut-off Conditions | Voltage / Current / Time / Capacity |
| Protection Function | Over/Under Voltage, Over/Under Current, Over Capacity, Power Failure Protection, Data Breakpoint Recovery | Model | XW-5V100A32CH |
| Support Battery Length | 65-370mm | Delivery Time | 15-30 working days after deposit |
| Time Range | 0-3000 Minutes | Support Battery Height | 90-250mm |
| Charge / Discharge Current | 5V 100A | Control Mode | Software-installed Computer, Whole Cabinet Control |
| Battery Type | Prismatic Cell | Fixture Form | Four-wire Method Fixture |
| Voltage Measurement Range | 0-5V | Communication Method | RS485, Baudrate 57600 |
| Process Setting | Up to 32 Steps and 256 Cycles | Discharge Cut-off Conditions | Voltage / Time / Capacity |
| Voltage Resolution | 0.1mV | Time Accuracy | ≤ ±1‰ |
| Supply Ability | 200 Sets per Month | Fixture Distance | 112mm |
| Working Power | ≤23kW | Data Processing | Record Voltage/Current/Time/Capacity; Auto-calculate Current Ratio, Capacity Loss, Discharge Efficiency, Average & Median Voltage; Graphs; Text/EXCEL/WORD/MDB Export |
| Constant Voltage Range | 2.0-4.5V | Current Accuracy | ±(0.5‰ Reading + 0.5‰ Full Scale) |
| Discharge Mode | Constant Current / Power / Resistance | Packaging Details | Plywood case with shock-proof foam, export-grade packaging |
| Battery Grading | By Capacity, Time, Open Circuit Voltage, Discharge Platform | Equipment Type | Battery Formation and Capacity Grading Machine |
| Charging Mode | Constant Current / Voltage / Current & Voltage | Sampling Inspection Cycle | 1-60s |
| Equipment Size (L x W x H) | 900 x 950 x 1840mm | Cooling Method | Natural Air Intake, Upward Exhaust |
| Brand Name | XWELL | Model Number | XW-5V100A32CH |
| Certification | CE, ISO 9001:2015 | Place of Origin | Guangdong, China |
| High Light | prismatic battery grading machine ,wide compatibility battery formation machine ,battery capacity grading machine with warranty | ||
Designed for flexibility, the XW-5V100A32CH supports prismatic cells from 65-370mm in length, 16-103mm in thickness and 90-250mm in height, with a 40-300mm P/N distance and a 112mm fixture distance for a wide range of battery sizes.
| Model | XW-5V100A32CH |
| Equipment Type | Battery Formation and Capacity Grading Machine |
| Number of Channels | 32 Channels |
| Battery Type | Prismatic Cell |
| Equipment Size (L x W x H) | 900 x 950 x 1840mm |
| Fixture Form | Four-wire Method Fixture |
| Fixture Distance | 112mm |
| Support Battery Length | 65-370mm |
| Support Battery Thickness | 16-103mm |
| Support Battery Height | 90-250mm |
| Support P/N Distance | 40-300mm |
| Working Power Supply | 3-phase 5-wire AC380V ±10%, 50Hz |
| Working Power | ≤23kW |
| Working Environment | Temperature 0-40°C, Relative Humidity ≤80% |
| Cooling Method | Natural Air Intake, Upward Exhaust |
| Voltage Measurement Range | 0-5V |
| Voltage Resolution | 0.1mV |
| Constant Voltage Range | 2.0-4.5V |
| Voltage Accuracy | ±(0.5‰ Reading + 0.5‰ Full Scale) |
| Current Accuracy | ±(0.5‰ Reading + 0.5‰ Full Scale) |
| Charge / Discharge Current | 5V 100A |
| Control Mode | Software-installed Computer, Whole Cabinet Control |
| Communication Method | RS485, Baudrate 57600 |
| Process Setting | Up to 32 Steps and 256 Cycles |
| Charging Mode | Constant Current / Voltage / Current & Voltage |
| Charging Cut-off Conditions | Voltage / Current / Time / Capacity |
| Discharge Mode | Constant Current / Power / Resistance |
| Discharge Cut-off Conditions | Voltage / Time / Capacity |
| Protection Function | Over/Under Voltage, Over/Under Current, Over Capacity, Power Failure Protection, Data Breakpoint Recovery |
| Time Range | 0-3000 Minutes |
| Time Accuracy | ≤ ±1‰ |
| Sampling Inspection Cycle | 1-60s |
| Battery Grading | By Capacity, Time, Open Circuit Voltage, Discharge Platform |
| Data Processing | Record Voltage/Current/Time/Capacity; Auto-calculate Current Ratio, Capacity Loss, Discharge Efficiency, Average & Median Voltage; Graphs; Text/EXCEL/WORD/MDB Export |
XWELL XW-5V100A32CH prismatic battery formation and capacity grading machine, engineered for accurate and efficient battery production.
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
2016
Total Annual:
3000000-5000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
GUANGDONG XWELL TECHNOLOGY CO., LTD. is a high-tech enterprise specializing in intelligent equipment design, production and sales, providing mechanical engineering technology design and consulting services, electronic engineering design and consulting services. XWELL's core team was established ... GUANGDONG XWELL TECHNOLOGY CO., LTD. is a high-tech enterprise specializing in intelligent equipment design, production and sales, providing mechanical engineering technology design and consulting services, electronic engineering design and consulting services. XWELL's core team was established ...
Get in touch with us
Leave a Message, we will call you back quickly!