| Warranty | 1 Year Warranty with Lifetime Support |
| After-sales Service | 24/7 Technical Support |
| Number Of Channels | 8/40/80 Channels |
| Voltage Range | 0~20V |
| Current Range | 0.02~10A (Single Channel) |
| Accuracy | ±0.02%FS+0.02%RD |
| Output Power | Max. 200W (Single Channel) |
| Power Supply | AC220V±10%, frequency: 50HZ±5% |
| Payment Terms | T/T,PayPal,L/C,Western Union |
| Supply Ability | 200 Sets/Month |
| Delivery Time | 7~35 Days |
| Packaging Details | Plywood Case |
| Brand Name | ACEY |
| Model Number | ACEY-ACTS-20V10A-GGS |
| Certification | CE |
| Place of Origin | China |
View Detail Information
Explore similar products
100V 100A Energy Saving Lithium Battery Pack Life Cycle Tester For Battery Pack
100V 150A Regenerative Battery Pack Charge Discharge Test Equipment
100V 100A Charge 100A Discharge Energy Saving Battery Pack Tester
100V 60A Charge 60A Discharge Regenerative Lithium Battery Aging Test Equipment
Product Specification
| Warranty | 1 Year Warranty with Lifetime Support | After-sales Service | 24/7 Technical Support |
| Number Of Channels | 8/40/80 Channels | Voltage Range | 0~20V |
| Current Range | 0.02~10A (Single Channel) | Accuracy | ±0.02%FS+0.02%RD |
| Output Power | Max. 200W (Single Channel) | Power Supply | AC220V±10%, frequency: 50HZ±5% |
| Payment Terms | T/T,PayPal,L/C,Western Union | Supply Ability | 200 Sets/Month |
| Delivery Time | 7~35 Days | Packaging Details | Plywood Case |
| Brand Name | ACEY | Model Number | ACEY-ACTS-20V10A-GGS |
| Certification | CE | Place of Origin | China |
| High Light | Hybrid battery charge and discharge tester ,Car battery charge and discharge tester ,Hybrid lithium battery testing machine | ||
20V 10A Hybrid Battery Repair Reconditioning Equipment For Toyota/Prius/Lexus/Honda/Camry Hev Car
Product Description
ACEY-ACTS-20V10A-GGS hybrid battery reconditioning equipment is designed to restore battery capacity and efficiency degraded by repeated charge and discharge cycles. By applying optimized and controlled charge–discharge profiles, the system helps improve overall battery performance and extend service life.
The equipment supports cycle life testing, capacity testing, charge and discharge characteristic analysis, charge retention evaluation, charge and discharge efficiency testing, and tolerance testing for overcharge and over-discharge conditions. It is suitable for lithium-ion, lead-acid, nickel-metal hydride, and nickel-cadmium batteries, and is widely used for battery aging tests, performance verification, and quality control in both production and laboratory environments.
With multiple channel configurations available, the system allows simultaneous reconditioning and testing of multiple battery modules, improving maintenance efficiency. It is well suited for hybrid vehicle battery repair and reconditioning, including popular models such as Toyota Prius and Camry, Lexus, Honda, and other hybrid vehicles.
Working Environment
Functional Description
Main Technical Parameter
| No. | Item | ACEY-ACTS-20V10A-GGS | ||
| 1 | Main channels | 8CH/module | ||
| 2 | Channels working mode | Independently | ||
| 3 | Main channel working mode | Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV | ||
| Discharge: CD, CP, CR | ||||
| Still | ||||
| Ending condition of main channel | Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, Temperature (NTC detection temperature and GGS temperature), etc. | |||
| 4 | Main channel Voltage | Test range of voltage | 0V-20V | |
| Min. discharge voltage | 1.5V | |||
| Accuracy | ±0.02%FS+0.02%RD(@25±3℃) | |||
| Resolution | 0.1mV | |||
| Main channel Current | Test range of current | ±10A | ||
| Min. output current | 20mA | |||
| Accuracy | ±0.02%FS+0.02%RD(@25±3℃) | |||
| Resolution | 1mA | |||
| Current start response time | <10ms | |||
| Time | Resolution | 10ms | ||
| Power | Output power | Single channel continuous working power 200W | ||
| Stability | ±0.05%FS+0.05%RD | |||
| Auxiliary channel parameter cutoff function | Main channel step can be set to stop or jump when auxiliary channel signal reach to a certain condition. | |||
| 5 | ACTS Communication | LAN | ||
| 6 | GGS Communication (Optional) | SMBUS, I2C, HDQ | ||
| Support reading 100kHz and 400kHz communication frequency battery information (software can be set and switched) | ||||
| Support single channel independent operation of different data communication protocols. (If GGS communication and INA231 communication are selected) | ||||
| Support multi-channel simultaneous sampling, and the data recording interval of the same channel is ≥ 1s (The same table as the charge and discharge data) | ||||
| 7 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||
| Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||
| Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||
| Cycle time | Max. 9,999 | |||
| Programmable step | Max. 9,999 | |||
| Nested loop | Max. 10 layers | |||
| Step time range | No limit, support h, min, s | |||
| Data record | Maximum recording time:10ms, voltage≤0.02%FS, current ≤0.02%FS | |||
| Program feature | Each step has one or multiple exit | |||
| Barcode scan | Support | |||
| 8 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |
| Process list | Process number, working mode, process time, capacity, power, medium voltage, cut-off voltage, cut-off current, etc. | |||
| Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||
| 9 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||
| 10 | Data saving | Save as files | ||
| 11 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time | ||
| Y-coordinate: total voltage, current, capacity, power, cell temperature | ||||
| 12 | Software protection | Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection | ||
| Hardware protection | Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP. | |||
| Warning function | Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. | |||
| 13 | Sampling terminals | Four-polar sampling. Crocodile clip or other clips. | ||
| 14 | Energy consumption | Heat dissipation | ||
| 15 | Cooling method | Forced Fan-cooled | ||
| 16 | Voice | Less than 70dB(Single set) | ||
| IP grade | IP20 | |||
| 17 | Repair | Modularized structure. Can be replaced or repair with spare parts. | ||
Product Display
![]()
![]()
![]()
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2009
Total Annual:
8,000,000.00-15,000,000.00
Employee Number:
80~120
Ecer Certification:
Verified Supplier
Acey New Energy is a high-tech enterprise specializing in the research, development, and manufacturing of advanced equipment for the lithium-ion battery industry. Established in 2009, Acey is supported by a professional R&D team and an experienced after-sales service team, each with more than 17... Acey New Energy is a high-tech enterprise specializing in the research, development, and manufacturing of advanced equipment for the lithium-ion battery industry. Established in 2009, Acey is supported by a professional R&D team and an experienced after-sales service team, each with more than 17...
Get in touch with us
Leave a Message, we will call you back quickly!