| Accuracy | ±(0.05%RD+0.05%FS) |
| Number Of Channels | 12 Channels |
| Delivery Time | 7~35 Days |
| After-sales Service | 24/7 Technical Support |
| Packaging Details | Plywood Case |
| Warranty | 1 Year Warranty with Lifetime Support |
| Payment Terms | T/T,PayPal,L/C,Western Union |
| Output Power | Max. 10KW (Single Channel) |
| Current Range | 0.1~100A (Charge & Discharge) |
| Voltage Range | 10V-100V |
| Main channel test abort condition | Time, voltage, current, capacity, etc |
| Supply Ability | 200 Sets/Month |
| Model Number | ACEY-BA100100-12 |
| Certification | CE |
| Brand Name | ACEY |
| Place of Origin | China |
View Detail Information
Explore similar products
100V 100A Energy Saving Lithium Battery Pack Life Cycle Tester For Battery Pack
100V 150A Regenerative Battery Pack Charge Discharge Test Equipment
100V 100A Charge 100A Discharge Energy Saving Battery Pack Tester
100V 60A Charge 60A Discharge Regenerative Lithium Battery Aging Test Equipment
Product Specification
| Accuracy | ±(0.05%RD+0.05%FS) | Number Of Channels | 12 Channels |
| Delivery Time | 7~35 Days | After-sales Service | 24/7 Technical Support |
| Packaging Details | Plywood Case | Warranty | 1 Year Warranty with Lifetime Support |
| Payment Terms | T/T,PayPal,L/C,Western Union | Output Power | Max. 10KW (Single Channel) |
| Current Range | 0.1~100A (Charge & Discharge) | Voltage Range | 10V-100V |
| Main channel test abort condition | Time, voltage, current, capacity, etc | Supply Ability | 200 Sets/Month |
| Model Number | ACEY-BA100100-12 | Certification | CE |
| Brand Name | ACEY | Place of Origin | China |
| High Light | 12S 100V battery aging machine ,100A programmable battery module tester ,battery pack testing equipment | ||
100V 100A Charge 100A Discharge Battery Pack Charge Discharge Test Equipment for Energy Storage Systems
Product Description
ACEY-BA100100-12 Energy Feedback Battery Charging and Discharging Testing Machine is designed for battery pack aging, capacity verification, charge-discharge performance evaluation, and temperature characteristic testing. It is suitable for battery pack manufacturing, production quality control, and battery performance assessment for lithium-ion, lithium iron phosphate, lead-acid, nickel-metal hydride, and nickel-cadmium battery packs. The system helps manufacturers evaluate battery capacity, charging and discharging behavior, cycle performance, and operating characteristics under programmable test conditions.
Applicable Battery Types
Lithium-ion battery packs, including ternary lithium and lithium iron phosphate batteries.
Lead-acid battery packs.
Nickel-metal hydride battery packs.
Nickel-cadmium battery packs.
Same-port and separate-port battery packs.
Battery modules with a voltage range of 10V to 100V.
Main Applications
Equipment Features
Programmable Test Steps: Configure charging, discharging, resting, and multi-level cycle sequences according to testing requirements.
Flexible Cutoff Conditions: Set test termination or step switching based on voltage, current, capacity, and time.
Smooth Current Transition: Soft-start output reduces current surges during test startup and CC-to-CV switching.
Detailed Data Recording: Records voltage, current, capacity, energy, temperature, and cycle information for test traceability.
Customizable Curve Analysis: Select and combine test curves to analyze charging and discharging behavior.
Abnormality Detection: Monitors voltage and current variations and can trigger alarms or suspend testing when abnormal conditions occur.
Four-Wire Connection: Separates current and voltage sensing lines for battery testing.
Modular Maintenance Design: Supports convenient power module maintenance and component replacement.
Main Technical Parameter
NO |
Item |
Function requirement |
||
1 |
Channel |
12 |
||
2 |
Action Mode |
Completely independent |
||
3 |
Main channel work mode |
Charging: constant current and constant voltage charging CCCV.&CC Discharge: constant current discharge CD.& CP Resting, stopping |
||
|
Main channel test abort condition |
Time, voltage, current, capacity, etc |
||
4 |
Voltage of main channel |
Votage range of Charge&discharge |
10V-100V |
|
Accuracy |
±(0.05%FS+0.05%RD) |
|||
Resolution |
1mV |
|||
Current of main channel |
Maximum output current |
100A |
||
Minimum output current |
100mA |
|||
Accuracy |
±(0.05%FS+0.05%RD) |
|||
Resolution |
1mA |
|||
Power |
Output |
Single channel continuous operation maximum power 10KW |
||
Auxiliary channel parameter cut-off function |
The main channel step can be set to stop or switch when the auxiliary channel signal reaches certain conditions. |
|||
5 |
Control program |
Support for power-down data protection, support for power outages, manual stopping and succession of tests from data files. |
||
Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, upper current limit, voltage and current trend. |
||||
Auxiliary channel protection conditions can be set and parameters can be set including: upper voltage limit, lower voltage limit, upper temperature limit and lower temperature limit. |
||||
Cycle times |
Max 9999 |
|||
Work step time unit |
h,min,s are available |
|||
Data logging |
Min 5S |
|||
6 |
Data display method |
Loop List |
cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage, etc. |
|
Process List |
process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. |
|||
|
Detailed list |
There are record serial number, system time, accumulated time, voltage, current, energy, power, etc. |
||
7 |
Data export method |
The data can be exported to EXCEL and chart files, which can provide a variety of data analysis curves such as charging and discharging efficiency, charging and discharging curves, voltage, capacity, current time characteristics, etc., and the curves can be imported into EXCEL. |
||
8 |
Curve Type |
X coordinate: total time, charging and discharging capacity, cycle times, etc., can be set freely. |
||
Y coordinate: total voltage, current, capacity, single body temperature, charge/discharge capacity, single body voltage, etc., can be set freely. |
||||
9 |
Software protection |
Power-down data protection, power-off pause renewal, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, abnormal discharge voltage fall rate protection. |
||
|
Hardware protection |
Battery reversal, over-current protection, over-voltage protection, short-circuit protection. |
||
|
Alarm function |
The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection. |
||
10 |
Output wire |
Four-wire connection mode with separate current and voltage lines. |
||
11 |
Maintainability |
Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period. |
||
12 |
Test channel and battery pack connection method |
Alligator clamp/OT clamps |
||
13 |
Equipment testing environment and technical requirements |
Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant Working environment: temperature -10℃~40℃ / humidity: 10%~90% |
||
|
Alarm function |
The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection. |
||
10 |
Output wire |
Four-wire connection mode with separate current and voltage lines. |
||
11 |
Maintainability |
Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period. |
||
12 |
Test channel and battery pack connection method |
Alligator clamp |
||
13 |
Equipment testing environment and technical requirements |
Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant |
||
Working environment: temperature -10℃~40℃ / humidity: 10%~90% |
||||
Product Display
![]()
FAQ 1: What is a battery pack charge and discharge testing machine used for?
The ACEY-BA100100-12 Battery Charging and Discharging Testing Machine is used for battery pack aging tests, charge-discharge cycle testing, capacity measurement, and battery performance evaluation. It supports programmable test procedures for battery manufacturing, module production, and quality control.
FAQ 2: Can a battery tester perform automatic charge and discharge cycle testing?
Yes. The ACEY-BA100100-12 Battery Charging and Discharging Testing Machine supports programmable charging, discharging, resting, and multi-level cycle testing. Users can configure test steps, cycle counts, and termination conditions to meet different battery testing requirements.
FAQ 3: Can a battery charging and discharging tester measure battery capacity and export test data?
Yes. The ACEY-BA100100-12 Battery Charging and Discharging Testing Machine records voltage, current, capacity, energy, and cycle data during testing. Its software supports Excel data export and curve analysis to help users evaluate charge-discharge performance and maintain test records.
Company Details
Business Type:
Manufacturer
Year Established:
2009
Total Annual:
8,000,000.00-15,000,000.00
Employee Number:
80~120
Ecer Certification:
Verified Supplier
Acey New Energy is a high-tech enterprise specializing in the research, development, and manufacturing of advanced equipment for the lithium-ion battery industry. Established in 2009, Acey is supported by a professional R&D team and an experienced after-sales service team, each with more than 17... Acey New Energy is a high-tech enterprise specializing in the research, development, and manufacturing of advanced equipment for the lithium-ion battery industry. Established in 2009, Acey is supported by a professional R&D team and an experienced after-sales service team, each with more than 17...
Get in touch with us
Leave a Message, we will call you back quickly!