Payment Terms | T/T |
Packaging Details | safety carton pack or plywood box |
Standard | IEC62560-1 fig8 |
Purpose | Testing a Non-Dimmable Lamp at a Dimmer or Electronic Switch |
Testing a Non-Dimmable Lamp at a Dimmer or Electronic Switch | 105 X 267 X220 W *D*H mm |
Ammeter input Power | AC 220V 50Hz |
Brand Name | KingPo |
Certification | Calibration Certificate (ISO17025) |
Place of Origin | China |
View Detail Information
Explore similar products
Circuit Light Testing Equipment Rectifying Effect Of High Pressure Sodium And
7006-47C For G5 Lampholders , 7006-60C For G13 Lampholders
Light Testing Equipment LED Aging Test Device 1000 Hours Test Duration
IEC 60598-1 Clause 8.15 Arrangement For Impact Test For Handlamps With A Handle
Product Specification
Payment Terms | T/T | Packaging Details | safety carton pack or plywood box |
Standard | IEC62560-1 fig8 | Purpose | Testing a Non-Dimmable Lamp at a Dimmer or Electronic Switch |
Testing a Non-Dimmable Lamp at a Dimmer or Electronic Switch | 105 X 267 X220 W *D*H mm | Ammeter input Power | AC 220V 50Hz |
Brand Name | KingPo | Certification | Calibration Certificate (ISO17025) |
Place of Origin | China | ||
High Light | temperature rise test equipment ,led testing equipment |
Test Circuit For Testing a Non-Dimmable Lamp at a Dimmer or Electronic Switch
1. Use
Applying non-dimmable self-ballasted lamps on a dimmer or an electronic switch is to be tested as a possible case of abnormal operation..
2. Reference standards
IEC60560-Fig8
4. Technical parameters
Internal dimension | 105 X 267 X220 W *D*H mm |
2 | potentiometer R1 |
3 | resistor R |
4 | Triac BTA16/700 |
5 | Diac DB3 |
6 | capacitor C1 = 100 nF |
7 | capacitor C2 = 68 nF to 150 nF |
8 | induction L1 = 3 mH |
9 | basic load, incandescent lamp P = 60 W |
11 | I r.m.s. Ammeter |
Ammeter input Power | AC 220V 50Hz |
Test procedure:
Determine R1 and S1 setting at which the maximum I r.m.s . occurs.
Test at this situation, and if the lamp passively fails within 60 min, repeat the test at 10 % lower I r.m.s . The lower I r.m.s . shall be set in the decreasing potentiometer resistance direction.
Company Details
Business Type:
Manufacturer
Year Established:
2000
Employee Number:
50~200
Ecer Certification:
Verified Supplier
Kingpo Technology Development Limited is a pioneer and leader of global safety testing equipment manufacturer.We offer one-stop service for worldwide labs from R&D,testing,production to after-sales service.We dedicate ourselves in achieving optimal production quality for our customers,reduce cos... Kingpo Technology Development Limited is a pioneer and leader of global safety testing equipment manufacturer.We offer one-stop service for worldwide labs from R&D,testing,production to after-sales service.We dedicate ourselves in achieving optimal production quality for our customers,reduce cos...