Payment Terms | T/T |
Supply Ability | 3 sets per month |
Delivery Time | 30 working days |
Packaging Details | safety carton pack or plywood box |
Flowmeter range: | 8L/min |
Control mode: | Computer |
Accuracy | 1pa |
Timing accuracy | 0.1s |
Brand Name | kingpo |
Model Number | KP-FT010 |
Certification | iso9001 ce |
Place of Origin | china |
View Detail Information
Explore similar products
IEC 62368-1 Annex E Pink Noise Generator,Meets The Requirements For Pink Noise
ISO 5356-1 Medical Gauge For Testing HME Patient Port Connector
ISO5356-1 Figure A.1 22mm Plug And Ring Test Gauges For Testing Anaesthetic And
ISO 80369-7 Fig C.4 Male Luer Reference Connector Hardness Steel Material
Product Specification
Payment Terms | T/T | Supply Ability | 3 sets per month |
Delivery Time | 30 working days | Packaging Details | safety carton pack or plywood box |
Flowmeter range: | 8L/min | Control mode: | Computer |
Accuracy | 1pa | Timing accuracy | 0.1s |
Brand Name | kingpo | Model Number | KP-FT010 |
Certification | iso9001 ce | Place of Origin | china |
High Light | tv signal tester ,mask test machine |
Mask resistance tester
1.Test standard: yy0469-2011 medical surgical mask
Differential pressure tester is used for pressure difference detection of surgical masks. The equipment is equipped with software, which can display pressure curve in real time, output test report and save test data. Meet the test standard yy0469-2011 surgical mask 5.7. YY/ t0969-2010, ventilation resistance 5.6
2. Features of equipment
1. The equipment is equipped with an air pump to simulate artificial respiration.
2. The detector is equipped with positive pressure sensor, which is used to collect the pressure of test data and reflect it to the computer software.
3. The pressure has a non-polar adjustable function, and the technical parameters such as the pressure holding time can be set.
3.Technical parameters of the tester
1. Flowmeter range: 8L/min.
2. Control mode: computer.
3. The micromanometer has a measuring range of 0-500pa and an accuracy of 1pa.
4. Timing accuracy: 0.1s.
Technical parameters
Fundamental | The vacuum pump was used to simulate breathing, and the pressure difference was tested. | |
Test pressure | 0-500pa | |
Microgauge range | 0-500pa,the accuracy is 1pa. | |
Pressure resolution | 1Pa | |
Time accurancy | 0.1s | |
Test medium | air | |
Control method | computer | |
Flow rate | 8L/min | |
Scope of application | surgical mask |
Configuration list
Name | Unit | Quantity | Remark |
Pressure sensor | unit | 1 | 佛山一众 |
Computer | unit | 1 | Lenovo |
Flowmeter | pcs | 1 | According to the flow |
Case | pcs | 1 | Aluminium profile |
Positive pressure bump | pcs | 1 | Simulated human exhalation |
Neddle valve | pcs | 2 | Regulated flow |
Electric appliance | set | 1 | Chint Group |
Decompression valve | pcs | 1 | Manual pressure |
Software | pcs | 1 | SUPY1.0 |
Company Details
Business Type:
Manufacturer,Trading Company,Exporter,Seller
Year Established:
2000
Total Annual:
8000000-1500000
Employee Number:
50~200
Ecer Certification:
Verified Supplier
.gtr-container { font-family: 'Arial', sans-serif; color: #333; line-height: 1.6; max-width: 1000px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin: 25px 0 15px 0; padding-bottom: 8px; border-bottom: 2px ... .gtr-container { font-family: 'Arial', sans-serif; color: #333; line-height: 1.6; max-width: 1000px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin: 25px 0 15px 0; padding-bottom: 8px; border-bottom: 2px ...
Get in touch with us
Leave a Message, we will call you back quickly!