Payment Terms | T/T |
Supply Ability | 20 pcs/ month |
Delivery Time | 12 working days |
Packaging Details | safety carton pack or plywood box |
Standard | ISO 18250-3 Fig C.1 |
test sample | Small-Bore Connectors for Liquids and Gases |
Application | Connectors for Enteral |
material | stainless steel |
Brand Name | kingpo |
Model Number | ISO 18250-3 Fig C.1 |
Certification | iso9001 ce |
Place of Origin | china |
View Detail Information
Explore similar products
IEC 62368-1 Annex E Pink Noise Generator,Meets The Requirements For Pink Noise
ISO 5356-1 Medical Gauge For Testing HME Patient Port Connector
ISO5356-1 Figure A.1 22mm Plug And Ring Test Gauges For Testing Anaesthetic And
ISO 80369-7 Fig C.4 Male Luer Reference Connector Hardness Steel Material
Product Specification
Payment Terms | T/T | Supply Ability | 20 pcs/ month |
Delivery Time | 12 working days | Packaging Details | safety carton pack or plywood box |
Standard | ISO 18250-3 Fig C.1 | test sample | Small-Bore Connectors for Liquids and Gases |
Application | Connectors for Enteral | material | stainless steel |
Brand Name | kingpo | Model Number | ISO 18250-3 Fig C.1 |
Certification | iso9001 ce | Place of Origin | china |
High Light | ISO 18250-3 Reference Connector ,Enteral Application Reference Connector ,Reservoir Delivery System Reference Connector |
ISO 80369-3 Figure C.1 and C.2 Female Reference Connectors
ISO 80369-3 Small-Bore Connectors for Liquids and Gases in Healthcare Applications - Part 3: Connectors for Enteral Applications; Annex C; Figure C.1 and Figure C.2 define the Female Reference Connectors are used in the tests specified in ISO 80369-3, Clause 6. Keeping with the experienced requirements of the medical industry; these ISO 80369-3 Figure C.1 and C.2 Female Reference Connectors are made from hardened stainless steel.
The ISO 80369-3 Figure C.1 and Figure C.2 Female Reference Connectors have design details which are not specified in ISO 80369-3 and which allow connection to test equipment. These design details vary by manufacturer. With the addition of an adapter the various designs will all work with the Enersol Test Equipment. The photos above help illuminate these design differences.
The ISO 80369-3 Figure C.1 and Figure C.2 Female Reference Connectors are an integral part of ENFit Small Bore Connector testing. The ISO ISO 80369-3 Figure C.1 and Figure C.2 Female Reference Connectors are assembled to samples for tests such as liquid leakage, air leakage, ease of assembly, unscrewing torque, separation force, resistance to overriding, and stress cracking.
Uses for the ISO 80369-3 Fig C.1 and C.2 Female Reference Connectors
Below is a list of tests which are best accomplished by using the ISO 80369-3 Figure C.1 and Figure C.2 Female Reference Connectors.
ISO 80369-3; Clause 6.1.2 - Fluid Leakage by Pressure Decay
To conduct the Fluid Leakage by Pressure Decay test found in ISO 80369-3 clause 6.1.2,it requires:
1 - Female Reference Connector ISO80369-3 Fig C.1
2 - Fitting Assembly Machine
3 - Automated Pressure Decay Tester
ISO 80369-3; Clause 6.1.3 - Positive Pressure Fluid Leakage
To conduct the Positive Pressure Fluid Leakage test found in ISO 80369-3 clause 6.1.3,it requires:
1 - Female Reference Connector ISO80369-3 Fig C.1
2 - Fitting Assembly Machine
3 - Automated Pressure Decay Tester
ISO 80369-3; Clause 6.2 - Stress Cracking
To conduct the Stress Cracking test found in ISO 80369-3 clause 6.2,it requires:
1 - Female Reference Connector ISO80369-3 Fig C.1
2 - Fitting Assembly Machine
ISO 80369-3; Clause 6.3 - Resistance to Seperation from Axial Load
To conduct the Resistance to Seperation from Axial Load test found in ISO 80369-3 clause 6.3,it requires:
1 - Female Reference Connector ISO80369-3 Fig C.2
2 - Fitting Assembly Machine
3 - Seperation force Device
ISO 80369-3; Clause 6.4 - Resistance to Seperation from Unscrewing
To conduct the Resistance to Seperation from Unscrewing test found in ISO 80369-3 clause 6.4,it requires:
1 - Female Reference Connector ISO80369-3 Fig C.1
2 - Fitting Assembly Machine
3 - Unscrewing Torque Device
ISO 80369-3; Clause 6.5 - Resistance to Overriding
To conduct the Resistance to Overriding test found in ISO 80369-3 clause 6.5,it requires:
1 - Female Reference Connector ISO80369-3 Fig C.2
2 - Fitting Assembly Machine
ISO 80369-3; Clause 6.6 - Disconnection by Unscrewing
To conduct the Disconnection by Unscrewing test found in ISO 80369-3 clause 6.6,it requires:
1 - Female Reference Connector ISO80369-3 Fig C.1
2 - Fitting Assembly Machine
3 - Disconnection by Unscrewing Tester
Company Details
Business Type:
Manufacturer,Trading Company,Exporter,Seller
Year Established:
2000
Total Annual:
8000000-1500000
Employee Number:
50~200
Ecer Certification:
Verified Supplier
KingPo Technology Development Limited is a global leader in manufacturing battery testing machines, environmental test chambers, and safety compliance testing equipment. As an industry pioneer, we provide one-stop solutions for laboratories worldwide, spanning R&D, testing, production, and after... KingPo Technology Development Limited is a global leader in manufacturing battery testing machines, environmental test chambers, and safety compliance testing equipment. As an industry pioneer, we provide one-stop solutions for laboratories worldwide, spanning R&D, testing, production, and after...
Get in touch with us
Leave a Message, we will call you back quickly!