| Payment Terms | T/T |
| Packaging Details | safety carton pack or plywood box |
| Standards | IEC 60335-2-40:2022 and GB/T 4706.32-2024 |
| Electrode Spark Gap | 0.5-10mm adjustable |
| Transformer Voltage Range | 0-20KV, resolution 1V |
| Discharge Time | 0.3s ± 0.05s |
| Brand Name | Kingpo |
| Model Number | KP-FT3541 |
| Certification | ISO 17025 |
| Place of Origin | China |
View Detail Information
Explore similar products
50w and 500w Flame Tester | IEC60695-11-3,IEC60695-11-4
Platinum Electrode For IEC 60112 CTI Tester Platinum Length ≥12mm
Copper Block With Omega K - TypeThermocouple IEC 60695-11-5 Fig A.1 Standard
220V 50-60Hz Thermocouple Welding Machine , Thermocouple Welder Equipment
Product Specification
| Payment Terms | T/T | Packaging Details | safety carton pack or plywood box |
| Standards | IEC 60335-2-40:2022 and GB/T 4706.32-2024 | Electrode Spark Gap | 0.5-10mm adjustable |
| Transformer Voltage Range | 0-20KV, resolution 1V | Discharge Time | 0.3s ± 0.05s |
| Brand Name | Kingpo | Model Number | KP-FT3541 |
| Certification | ISO 17025 | Place of Origin | China |
| High Light | IEC 60335-2-40:2022 Compliant Flame Test Equipment ,GB/T 4706.32-2024 Compliant A2L Refrigerant Test Chamber ,Adjustable Electrode Spark Gap Flame-Retardant Enclosure Test Machine | ||
1. Product Overview
The flame-retardant enclosure verification test chamber for A2L refrigerant is mainly used to test and verify the flame-retardant effect of flame-retardant enclosures in the event of A2L refrigerant leakage. The equipment complies with the requirements of IEC 60335-2-40:2022 and GB/T 4706.32-2024 standards. This test chamber simulates refrigerant leakage scenarios to test the flame-retardant performance of the enclosure after leakage.
2. Equipment Functions and Standards
This testing machine is designed according to international standards IEC 60335-2-40:2022 and GB/T 4706.32-2024, and is suitable for household appliances such as electric heat pumps, air conditioners, and dehumidifiers.
Its core functions include:
Simulating a refrigerant leak scenario, the flame-retardant effect of the flame-retardant enclosure was tested after the leak.
Verify whether the casing can effectively prevent the spread of flames after a leak.
Equipment composition
(1). One set of high-voltage spark generator
(2). One set of explosion-proof simulated environment chamber
(3). One control system
3 . Technical Parameters
(1). High-voltage spark generator
(2). Electrode Spark Gap: 0.5-10mm adjustable
(3). Transformer Voltage Range: 0-20KV, resolution 1V
(4). Discharge Time: 0.3s ± 0.05s
(5). Discharge Quantity: 30mA; Resolution: 0.01mA;
(6). Dry Bulb Humidity: 32℃ (can be set)
(7). Dew Point Temperature: 27℃ (can be set)
(8). Voltage Input: 220VAC
Company Details
Business Type:
Manufacturer,Trading Company,Exporter,Seller
Year Established:
2000
Total Annual:
8000000-1500000
Employee Number:
50~200
Ecer Certification:
Verified Supplier
.gtr-container { font-family: 'Arial', sans-serif; color: #333; line-height: 1.6; max-width: 1000px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin: 25px 0 15px 0; padding-bottom: 8px; border-bottom: 2px ... .gtr-container { font-family: 'Arial', sans-serif; color: #333; line-height: 1.6; max-width: 1000px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin: 25px 0 15px 0; padding-bottom: 8px; border-bottom: 2px ...