| Working Power | AC 220V±10% 50Hz |
| Competitive Price | Yes |
| Safe Package | Yes |
| Power | 220V 50/60HZ |
| Power Supply | 220V |
| Measure Range | 30~50℃ |
| Brand Name | kingpo |
| Model Number | KP-2021 |
| Certification | iso9001 ce |
| Place of Origin | china |
View Detail Information
Explore similar products
IEC 62368-1 Pink Noise Generator
ISO 5356-1 Medical Gauge For Testing HME Patient Port Connector
ISO5356-1 Figure A.1 22mm Plug And Ring Test Gauges For Testing Anaesthetic And
ISO 80369-7 Fig C.4 Male Luer Reference Connector Hardness Steel Material
Product Specification
| Payment Terms | T/T | Supply Ability | 100 |
| Delivery Time | 25 working days | Packaging Details | 5000*600*400CM |
| Shipping Method | Fedex.Door to door service | Working Power | AC 220V±10% 50Hz |
| Competitive Price | Yes | Safe Package | Yes |
| Power | 220V 50/60HZ | Power Supply | 220V |
| Measure Range | 30~50℃ | Brand Name | kingpo |
| Model Number | KP-2021 | Certification | iso9001 ce |
| Place of Origin | china | ||
| High Light | 50Hz Electrosurgery Analyzer ,Accurate Electrosurgery Analyzer ,220V Electrosurgery Analyzer | ||
0-500V RMS 10KHz-200MHz Medical Test Equipment
The KP2021 Electrosurgical Unit Analyzer, developed by KingPo Technology Development Limited, is designed specifically for testing the performance of electrosurgical units. It supports power testing, high-frequency leakage current testing, load curve testing, REM/CMQ testing, and is optimized for current method and voltage method testing functions to meet high-precision requirements.
Measurement Range: Voltage range of 0-5kV (RMS), covering a wide range of electrosurgical devices, including those operating above 1MHz.
High-Precision Testing: Supports testing of output current, voltage, power, crest factor, and RF leakage, compliant with IEC 60601-2-2 standards, ensuring patient safety and consistent device performance.
Touchscreen Operation: 10-inch high-definition touchscreen for user-friendly test sequence setup and data visualization.
Automated Testing: Streamlines testing with automated sequences, reducing test time (e.g., from 35 minutes to under 15 minutes with automation software similar to Fluke Biomedical's Ansur).
Data Management: Supports electronic record-keeping and data storage for long-term performance trend analysis and predictive maintenance, with USB data export to PC.
Superior High-Frequency Testing (>1MHz): Excels in testing electrosurgical devices operating above 1MHz, such as advanced minimally invasive or dental electrosurgical equipment, with high-precision digital measurement and Signal Averaging Mode (SAM) for stable results under fluctuating high-frequency signals.
| Parameter | Technical Specifications |
|---|---|
| Power | Range: 0–500W, Resolution: 0.1W, Accuracy: ≤50W: ±(5.0%*F+1)W; >50W: ±5.0% |
| Voltage (Voltage Method) | Range: 0–5kV (peak-to-peak), measured via differential voltage probe |
| Current (Current Method) | Range: 2mA–2000mA RMS, Resolution: 0.1mA, Accuracy: ±2.5% of reading |
| High-Frequency Leakage Current | Range: 2mA–500mA, Resolution: 0.1mA, Accuracy: ±2.5% of reading |
| Bandwidth | 30kHz–200MHz (measurement module bandwidth) |
| Load Impedance | 0–6400 ohms, 1-ohm step, Accuracy: ±1% (≥50Ω), ±3% (≥10Ω & <50Ω) |
| Internal Load Rated Power | Max 500W (rated load 500Ω) |
| Certifications | ISO 9001 and CE certified, ensuring quality and international standard compliance. |
Current Method Testing: Equipped with high-frequency current loop for precise current measurement (2mA–2000mA RMS, ±2.5% accuracy). Ideal for high-frequency leakage current testing and pulse mode analysis.
Voltage Method Testing: Features differential voltage probe for 0–5kV peak-to-peak voltage measurement. Essential for high-voltage output analysis and safety verification.
High-Voltage Warning: Avoid contact with connectors during operation (voltages >1000V).
Grounding Requirements: Always connect ground port to prevent electric shock.
Probe Usage: Ensure correct connection of current loop and voltage probe
IEC 60601-2-2: Ensures safety and performance of high-frequency electrosurgical equipment, including RF leakage current limits and output power testing (±10% accuracy).
ISO 17025: Calibration performed by CNAS/ilac-MRA accredited labs for traceability and accuracy.
IEC 60601: General safety standards for medical electrical equipment, covering grounding resistance and enclosure leakage testing.
Medical Device Manufacturers: For factory performance validation and quality control.
Hospitals and Biomedical Engineering: For routine maintenance and safety checks to ensure reliable operation and patient safety.
Laboratories: For R&D and performance analysis of new electrosurgical devices under varying loads.
Compared to competitors (e.g., Fluke Biomedical QA-ES III, Rigel Uni-Therm, Seaward), the KP2021 excels in testing electrosurgical devices operating above 1MHz:
Wide Frequency Coverage: Supports 50Hz to 5MHz, ensuring precise testing of high-frequency ESUs with SAM for stable signal measurement, outperforming Fluke Biomedical RF303RS in high-frequency signal stability.
Superior RF Leakage Testing: High-sensitivity module for accurate leakage current measurement at >1MHz, reducing test time and errors compared to Seaward’s manual load adjustments.
Automated Efficiency: Built-in automation and intuitive touchscreen reduce test time to under 15 minutes, surpassing Rigel Uni-Therm’s less user-friendly interface.
Impedance and Power Testing: Automated load adjustment and ±2.5% accuracy in power distribution tests, ideal for Argon-enhanced ESUs, unlike Fluke Biomedical’s reliance on additional accessories.
Safety and Versatility: Supports single and bipolar modes, inert gas flow/pressure testing, and RECM/CQM for high-frequency applications, offering broader functionality than Rigel Uni-Therm.
Company Details
Business Type:
Manufacturer,Trading Company,Exporter,Seller
Year Established:
2000
Total Annual:
8000000-1500000
Employee Number:
50~200
Ecer Certification:
Verified Supplier
.gtr-container { font-family: 'Arial', sans-serif; color: #333; line-height: 1.6; max-width: 1000px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin: 25px 0 15px 0; padding-bottom: 8px; border-bottom: 2px ... .gtr-container { font-family: 'Arial', sans-serif; color: #333; line-height: 1.6; max-width: 1000px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin: 25px 0 15px 0; padding-bottom: 8px; border-bottom: 2px ...
Get in touch with us
Leave a Message, we will call you back quickly!