| Payment Terms | L/C,D/A,D/P,T/T,Western Union |
| Supply Ability | 20 sets per month |
| Delivery Time | 10~15 work days |
| Packaging Details | Standard export wooden box |
| Product name | Differential Scanning Calorimetry Machine Providing Detailed Temperature and Gas Flow Settings with Touch Screen Interface |
| Temperature resolution | 0.01 ℃ |
| Heating rate | 0.1~40℃/min |
| Cooling rate | 0.1~20℃/min |
| DSC range | 0 ~ + 500 mw |
| DSC resolution | 0.01 mW |
| DSC sensitivity | 0.01 mW |
| Temperature control mode | Heating, cooling, constant temperature |
| Brand Name | JINHAIHU |
| Model Number | DSC-ZS5 |
| Certification | ISO9001 , CE |
| Place of Origin | BEIJING, CHINA |
View Detail Information
Explore similar products
Plastics 500mW Dsc Differential Scanning Calorimetry Machine
Determination Glass Transition Temperature Differential Scanning Calorimetry
0.1mW Oxidation Induction Time Test Machine For Plastic Analysis
Melting Crystallization Temperature Enthalpy ISO Heat Measure Instrument
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T,Western Union | Supply Ability | 20 sets per month |
| Delivery Time | 10~15 work days | Packaging Details | Standard export wooden box |
| Product name | Differential Scanning Calorimetry Machine Providing Detailed Temperature and Gas Flow Settings with Touch Screen Interface | Temperature resolution | 0.01 ℃ |
| Heating rate | 0.1~40℃/min | Cooling rate | 0.1~20℃/min |
| DSC range | 0 ~ + 500 mw | DSC resolution | 0.01 mW |
| DSC sensitivity | 0.01 mW | Temperature control mode | Heating, cooling, constant temperature |
| Brand Name | JINHAIHU | Model Number | DSC-ZS5 |
| Certification | ISO9001 , CE | Place of Origin | BEIJING, CHINA |
| High Light | Differential Scanning Calorimetry Machine with touch screen ,DSC machine with temperature control ,Calorimetry analyzer with gas flow settings | ||
Differential Scanning Calorimetry Machine Providing Detailed Temperature and Gas Flow Settings with Touch Screen Interface
Summary:
Features:
The industrial-grade widescreen touch interface presents comprehensive real-time data, including set temperature, sample temperature, oxygen flow rate, nitrogen flow rate, differential thermal signal, and various switch statuses.
Parameters:
| Temperature range | 0℃~500℃ |
| Temperature resolution | 0.01℃ |
| Heating rate | 0.1~40℃/min |
| Cooling rate | 0.1~20℃/min |
| Calorimetric resolution | 100%. |
| Constant temperature | 5℃~500℃ |
| Duration of constant temperature | The duration is recommended to be less than 24 hours. |
| Temperature control mode | Heating, cooling, constant temperature |
| DSC range | 0~±500mW |
| DSC resolution | 0.01mW |
| DSC sensitivity | 0.01mW |
| Working power | AC 220V 50Hz 300W or other |
| Atmosphere control gas | Two-channel gas control by automatic controlled (e.g. nitrogen and oxygen) |
| Gas flow | 0-200mL/min |
| Gas pressure | 0.2MPa |
| Gas flow accuracy | 0.2mL/min |
| Crucible | Aluminium crucible Φ6.6*3mm (Diameter * High) |
| Calibration standard | with standard material (indium, tin, zinc) |
| Data interface | Standard USB interface |
| Display mode | 7-inch touch screen |
| Output mode | computer and printer |
Configuration list:
| DSC machine | 1 set |
| Aluminium crucibles | 300 pieces |
| Power cords and USB cable | Each one |
| CD (contains software and operations video) | One |
| Soft-key | One |
| Oxygen airway and nitrogen airway | Each 5m |
| Operation manual | One |
| Standard sample(contains Indium, tin, zinc) | Each one |
| Tweezer and medicine spoon | Each one |
| Custom pressure reducing valve joint and quick joint | Two |
| Fused glass fuses | Four |
| External circulation thermostat sink | One |
| Water pipe | One |
Furnace bracket:
![]()
Software screenshots:
![]()
FAQ:
Q: What is the temperature control range and measurement accuracy of this DSC analyzer?
A: The temperature control range covers from ambient temperature to 600℃, with a temperature measurement accuracy of ±0.1℃ and a temperature repeatability error less than 0.05℃, ensured by dual temperature probes and proprietary temperature control technology.
Q: What is the adjustable range of heating and cooling rates for the DSC furnace?
A: The heating rate is adjustable from 0.1℃/min to 99.9℃/min, and the cooling rate ranges from 0.1℃/min to 50℃/min (supported by compressor-driven circulating cooling water), meeting diverse test rate requirements.
Q: What are the specifications of the gas control system for this DSC instrument?
A: It is equipped with a dual-channel gas automatic switching system (oxygen and nitrogen), with a flow adjustment range of 0-500 mL/min and a switching stabilization time of less than 10 seconds, ensuring stable and accurate gas supply during oxidation induction period tests.
![]()
![]()
![]()
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2013
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Beijing Jinshengxin testing machine Co., Ltd, covering 20,000 square meters, is located in Jinhaihu Town of Beijing. Since founded in 2003, our company has been devoted to the research, development and manufacture of testing machines for metallic and non-metallic materials, especially b... Beijing Jinshengxin testing machine Co., Ltd, covering 20,000 square meters, is located in Jinhaihu Town of Beijing. Since founded in 2003, our company has been devoted to the research, development and manufacture of testing machines for metallic and non-metallic materials, especially b...
Get in touch with us
Leave a Message, we will call you back quickly!