| 0.5‰ High-Precision Calibration | High-precision voltage and current calibration for accurate test results. |
| Payment Terms | T/T |
| Advanced Thermal Management | Dual-fan forced cooling supports stable long-term operation. |
| Real-Time Temperature Protection | Continuous battery temperature monitoring enhances testing safety. |
| Delivery Time | 7-10 Days |
| Modular Channel Configuration | Flexible channels support independent configuration and parallel operation. |
| Supply Ability | 50sets per month |
| Multi-Battery Compatibility | Adjustable fixtures accommodate different cell and battery pack formats. |
| Intelligent Precision Ranging | Automatic range switching maintains accuracy across different test stages. |
| Smooth CC/CV Transition | Four-wire sensing and soft-start control for stable charging. |
| RCDS-200V150A | High-power charge and discharge testing for lithium battery cells and packs. |
| Packaging Details | Standard Export Wooden Case Packaging |
| Model Number | RCDS-200V150A |
| Place of Origin | CHINA |
| Certification | As required |
| Brand Name | AWT |
View Detail Information
Explore similar products
Matrix Type BESS Testing System (3x2.5 MW)
Matrix-Type BESS Testing System (2x2.5 MW)
100V 120A Lithium Battery Pack Final Testing Machine Battery Test Equipment
64S BMS Testing System
Product Specification
| 0.5‰ High-Precision Calibration | High-precision voltage and current calibration for accurate test results. | Payment Terms | T/T |
| Advanced Thermal Management | Dual-fan forced cooling supports stable long-term operation. | Real-Time Temperature Protection | Continuous battery temperature monitoring enhances testing safety. |
| Delivery Time | 7-10 Days | Modular Channel Configuration | Flexible channels support independent configuration and parallel operation. |
| Supply Ability | 50sets per month | Multi-Battery Compatibility | Adjustable fixtures accommodate different cell and battery pack formats. |
| Intelligent Precision Ranging | Automatic range switching maintains accuracy across different test stages. | Smooth CC/CV Transition | Four-wire sensing and soft-start control for stable charging. |
| RCDS-200V150A | High-power charge and discharge testing for lithium battery cells and packs. | Packaging Details | Standard Export Wooden Case Packaging |
| Model Number | RCDS-200V150A | Place of Origin | CHINA |
| Certification | As required | Brand Name | AWT |
| High Light | 200V BESS Testing Solution ,150A BESS Testing Solution ,30CH Battery Charging And Discharging Tester | ||
Regenerative Battery Charging and Discharging Tester – 200V 150A – 30CH
Model:RCDS-200V150A
Application:
Circle Life Testing and quality control in Battery mass production or Lab including lithium ion batteries, lead-acid batteries, cadmium-nickel batteries and nickel-hydrogen batteries
Function:
Environmental Requirements and Technical Parameters
Specification
| Model | RCDS-200V150A | |||||
|---|---|---|---|---|---|---|
| 1 | Main channel | 30 CH | ||||
| 2 | Channel Action mode | Independence | ||||
| 3 | Main Channel Working Mode | Charging: constant current charge CC, constant voltage charge CV, constant current charge CCCV. | ||||
| No impulse voltage and current should be realized In the process of constant current and constant voltage charging | ||||||
| Discharge: constant current discharging CD, constant power discharging CP, constant resistance discharging CR; stationary; | ||||||
| Main Channel Test Termination Conditions | Time, total voltage, total current, capacity, - V, Vcell, RSOC, etc. | |||||
| 4 | Main channel voltage | Single channel measurement range | 0V-200V | |||
| Minimum discharge voltage | 6V(Port voltage) | |||||
| Accuracy | ±(0.05%FS+0.05%RD) | |||||
| Resolution | 1mV | |||||
| Main channel current | Single channel measurement range | ±150A | ||||
| Minimum output current | 30mA | |||||
| Accuracy | ±(0.05%FS+0.05%RD) | |||||
| Resolution | 1mA | |||||
| Current Start Response Time | <10ms | |||||
| Time | Resolution | 10ms | ||||
| Power | output power | Single Channel Continuous Operating Power 3000W | ||||
| Stability | ±(0.1%FS+0.1%RD) | |||||
| 5 | RCDS comm mode | LAN | ||||
| BMS Comm | Support CAN2.0A, CAN 2.0B; RS485 communication Support DBC import, realize data reading with BMS CAN, and participate in process control | |||||
| 6 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||||
| Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||||
| Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||||
| Cycle time | Max. 9,999 | |||||
| Programmable step | Max. 9,999 | |||||
| Nested loop | Max. 10 layers | |||||
| Step time range | No limit, support h, min, s | |||||
| Data record | Time≥1S, voltage≥1mV, current ≥1mA | |||||
| Program feature | Each step has one or multiple exit | |||||
| 7 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |||
| Process list | Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc. | |||||
| Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||||
| 8 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||||
| 9 | Data saving | Save as files | ||||
| 10 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time | ||||
| Y-coordinate: total voltage, current, capacity, power, cell temperature | ||||||
| 11 | Software protection | Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection | ||||
| Hardware protection | Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP. | |||||
| Warning function | Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. | |||||
| 12 | Sampling terminals | Four-polar sampling. Crocodile clip or other clips. | ||||
| 13 | Energy consumption | Discharge power feedback to grid | ||||
| 14 | Cooling method | Forced Fan-cooled | ||||
| 15 | Safety grade | In accordance with EN60950, GB4943 | ||||
| Voice | Test voice by IEC62040-3 and voice is less than 70dBA. Sound level meter should be accordance with Ⅰtype in IEC804, Accuracy should be better than ±0.5dB. | |||||
| IP grade | IP20 | |||||
| 16 | Thunder proof | Reach GB17626 2-pole lightning protection requirements. | ||||
| 17 | Repair | Modularized structure. Can be replaced or repair with spare parts. Free during warranty period. | ||||
| Software update | For lifetime until hardware incompatible. | |||||
Feature
Company Details
Business Type:
Manufacturer
Year Established:
2004
Total Annual:
5000000-10000000
Employee Number:
100~200
Ecer Certification:
Verified Supplier
AWT – Battery PACK Automation & Energy Storage Production Line Manufacturer AWT is an automation equipment manufacturer specializing in lithium battery PACK assembly equipment, energy storage battery PACK production lines, automated welding systems, and complete battery manufacturing sol... AWT – Battery PACK Automation & Energy Storage Production Line Manufacturer AWT is an automation equipment manufacturer specializing in lithium battery PACK assembly equipment, energy storage battery PACK production lines, automated welding systems, and complete battery manufacturing sol...
Get in touch with us
Leave a Message, we will call you back quickly!