| Input impedance | 10MΩ |
| Dimensions | 138*68*35mm |
| Max voltage | 1000V DC or 750V AC |
| Payment Terms | T/T,Western Union |
| Delivery Time | 3-5 working days |
| Rotation rate | 3 revolutions/second |
| Display counts | 4000 |
| Packaging Details | Color paper box |
| Power supply | 2 x 1.5V AAA battery |
| Supply Ability | More than 10000pcs per month |
| Model Number | VC97 |
| Certification | CE,ROHS |
| Brand Name | Benetech, Bestone |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
WT65 Visual Fault Locator and Optical Power Meter with 850nm/1300nm/1625nm
Digital Earth Resistance Tester Dustproof Waterproof AR4105A
Dustproof and Waterproof Digital Earth Resistance Tester with Big LCD Display
Non-Contact Clamp Earth Resistance Tester with 0.01~1000W Range and Double
Product Specification
| Input impedance | 10MΩ | Dimensions | 138*68*35mm |
| Max voltage | 1000V DC or 750V AC | Payment Terms | T/T,Western Union |
| Delivery Time | 3-5 working days | Rotation rate | 3 revolutions/second |
| Display counts | 4000 | Packaging Details | Color paper box |
| Power supply | 2 x 1.5V AAA battery | Supply Ability | More than 10000pcs per month |
| Model Number | VC97 | Certification | CE,ROHS |
| Brand Name | Benetech, Bestone | Place of Origin | CHINA |
| High Light | VC97 digital multimeter with True-RMS ,4000 counts LCD multimeter with thermocouple ,K-type thermocouple digital multimeter | ||
Professional digital multimeter designed for accurate electrical measurements with comprehensive functionality and safety features.
| Measuring Range | Resolution | Accuracy |
|---|---|---|
| 400mV | 0.1mV | ±(0.5%Reading+8digits) |
| 4V | 1mV | ±(0.5%Reading+8digits) |
| 40V | 10mV | ±(0.5%Reading+8digits) |
| 400V | 100mV | ±(0.5%Reading+8digits) |
| 1000V | 1mV | ±(0.5%Reading+8digits) |
Input impedance: 10MΩ | Maximal input voltage: 1000V DC or 750V AC valid value
| Measuring Range | Resolution | Accuracy |
|---|---|---|
| 400mV | 0.1mV | ±(1% readings +10 digits) |
| 4V | 1mV | ±(1% readings +10 digits) |
| 40V | 10mV | ±(1% readings +10 digits) |
| 400V | 100mV | ±(1% readings +10 digits) |
| 750V | 1mV | ±(1% readings +10 digits) |
Input impedance: 10MΩ | Maximal input voltage: 1000V DC or 750V AC valid value | Frequency response: 40Hz-2kHz True-Rms
| Measuring Range | Resolution | Accuracy |
|---|---|---|
| 1%~99% | 0.1% | ±(2.5%Reading+5 digits) |
Input voltage range: 200mV-10V AC valid value | Overload protection: 250V DC/AC
| Measuring Range | Resolution | Accuracy |
|---|---|---|
| 9.999Hz | 0.001Hz | ±(1.5%Reading +5 digits) |
| 99.99Hz | 0.01Hz | ±(1.5%Reading +5 digits) |
| 999.9Hz | 0.1Hz | ±(1.5%Reading +5 digits) |
| 9.999KHz | 0.001KHz | ±(1.5%Reading +5 digits) |
| 99.99KHz | 0.01KHz | ±(1.5%Reading +5 digits) |
| 999.9KHz | 0.1KHz | ±(1.5%Reading +5 digits) |
| 9.999MHz | 0.001MHz | ±(1.5%Reading +5 digits) |
Overload protection: 250V DC/AC
| Measuring Range | Resolution | Accuracy |
|---|---|---|
| -20℃~1000℃ | 1℃ | ±(1% readings +3 digits) |
| -4℉~1832℉ | 1℉ | ±(1% readings +3 digits) |
Overload protection: 250V DC/AC
| Measuring Range | Resolution | Accuracy |
|---|---|---|
| 40nF | 0.01nF | ±(4%Reading +5 digits) |
| 400nF | 0.1nF | ±(4%Reading +5 digits) |
| 4μ | 0.001μF | ±(4%Reading +5 digits) |
| 4μF | 0.01μF | ±(4%Reading +5 digits) |
| 400μF | 0.1μF | ±(4%Reading +5 digits) |
| 4mF | 0.001mF | ±(4%Reading +5 digits) |
| 40mF | 0.01mF | ±(4%Reading +10 digits) |
Overload protection: 250V DC/AC
| Measuring Range | Resolution | Accuracy |
|---|---|---|
| 400Ω | 0.1Ω | ±(0.8% Reading + 5 digits) |
| 4kΩ | 1Ω | ±(0.8% Reading + 5 digits) |
| 40kΩ | 10Ω | ±(0.8% Reading + 5 digits) |
| 400kΩ | 100Ω | ±(0.8% Reading + 5 digits) |
| 4MΩ | 1kΩ | ±(0.8% Reading + 5 digits) |
| 40MΩ | 10kΩ | ±(0.8% Reading + 5 digits) |
Overload protection: 250V DC/AC
| Measuring Range | Resolution | Accuracy |
|---|---|---|
| 40mA | 0.01mA | ±(1.2% Reading + 5 digits) |
| 400mA | 0.1mA | ±(1.2% Reading + 5 digits) |
| 10A | 10mA | ±(3% Reading + 5 digits) |
Overload Protection: Protective tube for mA measuring range (GR256/400); Protective tube for 10A measuring range (F10A/250V)
Maximal Input Voltage: mA position: 400mA DC/AC (valid value); 10A position: 10A DC/AC (valid value)
Important: When measured current exceeds 5A, continuous measurement duration should not exceed 10 seconds. Wait 1 minute before next measurement.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Trading Company,Seller
Year Established:
2010
Employee Number:
100~1000
Ecer Certification:
Verified Supplier
Shenzhen Bestone Industrial Co.Ltd. is equipped with modernized and standardized production lines for measuring instruments and testing equipment. We integrate precision processing, automated assembly, aging testing, calibration, and quality inspection into a complete manufacturing system. Under t... Shenzhen Bestone Industrial Co.Ltd. is equipped with modernized and standardized production lines for measuring instruments and testing equipment. We integrate precision processing, automated assembly, aging testing, calibration, and quality inspection into a complete manufacturing system. Under t...