China factories

China factory - Zhangjiagang Bestran Technology Co., Ltd.

Zhangjiagang Bestran Technology Co., Ltd.

  • China
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China AC DC Battery Vascular Doppler Machine for Arterial and Venous Blood Flow
China AC DC Battery Vascular Doppler Machine for Arterial and Venous Blood Flow

  1. China AC DC Battery Vascular Doppler Machine for Arterial and Venous Blood Flow
  2. China AC DC Battery Vascular Doppler Machine for Arterial and Venous Blood Flow
  3. China AC DC Battery Vascular Doppler Machine for Arterial and Venous Blood Flow

AC DC Battery Vascular Doppler Machine for Arterial and Venous Blood Flow

  1. MOQ: 1pc
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, Western Union, MoneyGram
Supply Ability 500pcs per Month
Delivery Time 3-5 days
Packaging Details Packing size:51*42.5*27cm, 1pc/carton, N.W.:5.2KG, G.W.:8.6KG
Product Vascular Doppler
Power AC and DC Battery
Usage Arterial and Venous Blood Flow Velocity
Display Colour Touch LCD
Ultrasound frequency 8MHz
USB Port Yes
Probe detect 8MHz
Ultrasound intensity 10mW/cm2
Brand Name Bestran
Model Number BT-VD02
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, MoneyGram Supply Ability 500pcs per Month
Delivery Time 3-5 days Packaging Details Packing size:51*42.5*27cm, 1pc/carton, N.W.:5.2KG, G.W.:8.6KG
Product Vascular Doppler Power AC and DC Battery
Usage Arterial and Venous Blood Flow Velocity Display Colour Touch LCD
Ultrasound frequency 8MHz USB Port Yes
Probe detect 8MHz Ultrasound intensity 10mW/cm2
Brand Name Bestran Model Number BT-VD02
Certification CE Place of Origin China
High Light AC DC Battery Vascular DopplerColour Touch LCD Vascular Doppler8MHz Ultrasound Vascular Doppler Machine

AC DC Battery Vascular Doppler Flowmeter Arterial Venous Blood Flow Velocity Colour Touch LCD

 

1. Vascular Doppler Both AC and DC Battery Power:

  • Enhanced Mobility and Versatility: The dual power source feature (AC and DC battery) ensures that the Vascular Doppler can be used both in a clinical setting where mains power is available and in more mobile or remote environments where access to electricity is limited. Whether in an outpatient clinic, at a patient's home, or during emergency situations, the ability to run on DC battery power allows healthcare providers to perform diagnostic tests without interruptions.
  • Uninterrupted Functionality: Having both AC and DC battery power options ensures continuous operation during extended assessments. If the AC power supply is cut off or if the device is transported between locations, the device can switch seamlessly to battery mode. This minimizes downtime and enhances the reliability of the equipment, particularly in critical moments where monitoring and immediate feedback are needed.
  • Longer Battery Life and Efficiency: Modern Vascular Doppler devices are designed with energy efficiency in mind, allowing for longer usage times on battery power. This makes the device ideal for long-term use during procedures like ambulatory monitoring or when performing follow-up diagnostics in situations where charging access may not be readily available.
  • Convenient for Emergency Situations: In urgent care settings or emergency rooms, where a quick assessment of vascular conditions is crucial, the portability offered by battery power can be a lifesaver. Clinicians can perform quick diagnostics on patients without waiting for external power sources or being confined to a fixed location.

2. Vascular Doppler Arterial and Venous Blood Flow Velocity Measurement:

  • Comprehensive Vascular Assessment: The ability to measure Arterial and Venous Blood Flow Velocity allows for a complete evaluation of both arterial and venous health. This is particularly useful in diagnosing conditions such as peripheral arterial disease (PAD), deep vein thrombosis (DVT), varicose veins, and other circulatory issues. The measurement of both arterial and venous flow velocities helps provide a holistic picture of the patient’s vascular health, making the device a vital tool for a wide range of clinical applications.
  • Precise Diagnosis of Blood Flow Abnormalities: By measuring blood flow velocity, the Vascular Doppler helps detect abnormal flow patterns that can indicate issues like arterial blockages, narrowed arteries, or venous insufficiency. For example, in arterial monitoring, a decreased flow velocity may point to the presence of stenosis or atherosclerosis. In venous monitoring, an increased velocity or abnormal flow direction could suggest conditions like deep vein thrombosis (DVT) or venous reflux.
  • Non-invasive and Real-Time Monitoring: The real-time assessment of blood flow velocity through Doppler ultrasound allows clinicians to monitor vascular health without invasive procedures. This non-invasive approach is not only safer for patients but also offers immediate feedback during diagnostics, which can guide treatment decisions right away.
  • Evaluation of Treatment Progress: Monitoring the velocity of both arterial and venous blood flow before, during, and after treatment (such as stent placement, bypass surgery, or anticoagulation therapy) helps clinicians track the effectiveness of interventions. Changes in velocity can indicate improvements or complications in the vascular system, providing valuable insights into patient recovery and the success of interventions.

 

Vascular Doppler Technical Parameter:

 

Functions BT-VD01 BT-VD02
Display type B/W Colour
Display content Cursor Wave
Touch screen No Yes
Li-ion battery Yes Yes
Probe detect Yes Yes
 

 

Vascular Doppler Usage

BT-VD01/02vascular doppler is used to detect arterial and venous blood flow velocity to assess peripheral vascular disease, feasible in andrology, urology, surgery,surgical,microsurgery, orthopedics, vascular surgery, burns surgery and plastic surgery departments.

 

Vascular Doppler Features

● Sensitive special purpose probe

● Display with strength cursor (BT-VD01),with colour touch LCD (BT-VD02)

● Both of AC and DC battery

● Auto power off

● USB to transmit the data to computer

● Output with loudspeaker and earphone

 

Vascular Doppler Technical Specification

● Ultrasound frequency: 8MHz

● Ultrasound intensity: <10mW/cm2

● Power supply: 7.4V Li-ion Rechargeable battery

AC 220/110V, 50/60Hz

● Display: 65mm×50mm LCD

● Dimension :130mm ×100mm ×65mm

● Gross weight:About 600g

 

Vascular Doppler Configuration

● Main body

● Li-ion battery

● 8MHz probe

● Adaptor

 

Vascular Doppler Option

● Earphone

● Gel

● Carry case

 

Vascular Doppler Product Mode

● Neutral

● OEM

● ODM

● SKD

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter

  • Year Established:

    2000

  • Total Annual:

    1500000-2000000

  • Employee Number:

    80~120

  • Ecer Certification:

    Verified Supplier

Zhangjigang Bestran Technology Co.,Ltd is established in 2000, we are a professional and quality-oriented manufacturer of hospital furniture and equipment,have advanced production management experience over 25 years in medical field.   We are located in new-model and green Zhangjiagang... Zhangjigang Bestran Technology Co.,Ltd is established in 2000, we are a professional and quality-oriented manufacturer of hospital furniture and equipment,have advanced production management experience over 25 years in medical field.   We are located in new-model and green Zhangjiagang...

+ Read More

Get in touch with us

  • Reach Us
  • Zhangjiagang Bestran Technology Co., Ltd.
  • Renmin Road,Yangshe Town,Zhangjiagang city, 215600,China
  • https://www.bestranmedical.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement