China factories

Chat Now Send Email
China factory - Biovantion Inc.

Biovantion Inc.

  • China,Beijing ,Beijing
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Triiodothyronine T3 ELISA Test Kit / Elisa Screening Kit Results in 2-3 hours
China Triiodothyronine T3 ELISA Test Kit / Elisa Screening Kit Results in 2-3 hours

  1. China Triiodothyronine T3 ELISA Test Kit / Elisa Screening Kit Results in 2-3 hours
  2. China Triiodothyronine T3 ELISA Test Kit / Elisa Screening Kit Results in 2-3 hours

Triiodothyronine T3 ELISA Test Kit / Elisa Screening Kit Results in 2-3 hours

  1. MOQ: 1000 Box
  2. Price: Discussible
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 100000 Box/carton
Delivery Time 2-7 days
Packaging Details carton/box
Delivery Within 48 hours
Packaging Specifications 8 x 12 strips, 96 wells
Country Of Origin China,BeiJing
Detection Limit 18 months
Storage 2-8℃
Specimen Whole blood
Assification class1
Product Type Elisa Test Kit
Brand Name BIOVANTION
Model Number TY0031
Certification ISO 13485
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 100000 Box/carton
Delivery Time 2-7 days Packaging Details carton/box
Delivery Within 48 hours Packaging Specifications 8 x 12 strips, 96 wells
Country Of Origin China,BeiJing Detection Limit 18 months
Storage 2-8℃ Specimen Whole blood
Assification class1 Product Type Elisa Test Kit
Brand Name BIOVANTION Model Number TY0031
Certification ISO 13485 Place of Origin CHINA
High Light Triiodothyronine ELISA Test KitT3 ELISA Test KitTriiodothyronine Elisa screening kit

                   Triiodothyronine(T3) ELISA Test Kit

INTENDED USE

   Detection Kit for 3,5,3'-Triiodothyronine(T3)(Enzyme-Linked ImmunoSorbent Assay , ELISA)It is used in quantitative tests for 3,5,3’-triiodothyronine (T3) in human serum.) in human serum.

SUMMARY AND CLINICAL SIGNIFICANCE

  The thyroid gland is essential for the development of many tissues and for the adjustement of their metabolism. These processes are under the control of thyroid hormones, T4 and T3.

Under stimulation by pituitary thyrotropin(TSH). the thyroid gland essentially secretes T4 with minute amounts of T3.

Tissue recptors to thyroid hormones are T3 receptors, T3 represents thus the acive entity among thyroid secretions.

The bulk of circulating T3 is produced by peripheral deiodination of T4 alternatively, T4 yields reverse T3(or RT3), a poorly active thyronine.

In the blood,T3 circulates free and bound to the same carrier protein transporting T4, thyroxine binding globulin or TBG. Nevertheless, T3 binding affinity to TBG is significantly less than that of T4; The free T3 serum concentration represents about 0.3% of the total circulating T3 concentration.

Under normal conditions, total T3 level is negatively. Correlated to serum TSH level due to the negative feed -back mechanism regulating thyroid funcion.

Product list

Product details Description
Delivery Within 48 hours
Packaging Specifications 8 x 12 strips, 96 wells
Country Of Origin China
Manufacturer 18 months
Preservation method 2℃-8℃
Specimen Whole blood
Assification class1
Type Elisa Test Kit

PRINCIPLE

T3 kit is based on competitive method. Coat micro well plates with anti-T3 to form solid-phase antibody. The T3 of sample and biotin-T3 compet with anti-T3 on solid-phase. Vidin-HRP added, solid phase antibody-biotinylated T3-avidin-HRP complex was formed. Add substrate and detect absorbent value. Calculate T3 content of patient serum through computer or plotting fitting concentration-absorbent value curve.

MAIN COMPONENTS

  • Coated Microplate: 1 plate (8×12 wells), Ready to use. Coated with anti-T3 antibody and sealed in an aluminum bag. Remove the strips in the resealable bag with a desiccant to protect from moisture after opened. Store at 2~8℃ until expiration date.
  • Biotin-T3: 1 vial of 6ml, Ready to use. Store at 2~8℃ until expiration date.
  • Avidin-HRP Conjugate: 1 vial of 6ml, Ready to use. Store at 2~8℃ until expiration date.
  • Calibrator: 6 vials of 1ml, Ready to use. Labeled with S0 to S5 and the concentration of T3 is 0,0.5,1.0,2.0,4.0,8.0 ng/ml. Store at 2~8℃ until expiration date.
  • Control: 2 vials of 1ml, Ready to use. Store at 2~8℃ until expiration date. The concentration of low value is 0.63~1.17ng/ml. The concentration of high value is 2.8~5.2 ng/ml.
  • Chromogen A: 1 vial of 7ml, Ready to use. Store at 2~8℃ until expiration date.
  • Chromogen B: 1 vial of 7ml, Ready to use. Store at 2~8℃ until expiration date.
  • Stop Solution: 1 vial of 7ml, Ready to use. Store at 2~8℃ until expiration date.
  • Wash buffer: 1 vial of 15ml, Concentrate 20-fold, diluting with deionized water before the assay. Store at 2~8℃ until expiration date.
  • Plate sealer: 2 pieces.
  • Plastic resealable bag: 1 set.
  • Instruction manual: 1 copy.

RELATED TIPS

  • This kit is designated for In-Vitro Diagnostic Use Only.
  • Wash procedure. Incomplete washing will adversely affect the test results. Wash each well 3 times with about 0.3ml wash buffer. If no automatic washer is available, washing can be performed manually as follows: Invert the plate vigorously to get all wash buffer out and block the rim of well on absorbent paper for a few seconds. Filling each well with water and remain 10 seconds. Repeat these steps 3 times. Blot dry the plate by inverting the plate onto absorbent tissue, and striking a hard surface several times.
  • Drip procedure. Mix the bottle gently before use. Violent surge may cause too much foam. Invert the bottle and squeeze one or two drop on absorbent tissue to make sure there is no foam. Take the bottle upright the well and make sure the drop does not touch the rim of wells.
  • Read procedure. Using the blank well to correct the zero point of reader if single wavelength reader is used. If double wavelength readers with 450nm and 630nm are used, there is no need to correct the zero point.

Storage. The whole kit should be stored at 2~8℃ for one year. Microplate should be

 

PREPARATIONS

1.  Allow all specimens and reagents to reach room temperature (~25°C) and mix thoroughly by gentle inversion before use.

2.Prepare Wash Buffer by diluting Wash Concentrate 20-fold with deionized water. The diluted wash solution is stable in room temperature for at least one week.

ATTENTIONS

  • This kit is designated for In-Vitro Diagnostic Use Only.
  • Wash procedure. Incomplete washing will adversely affect the test results. Wash each well 3 times with about 0.3ml wash buffer. If no automatic washer is available, washing can be performed manually as follows: Invert the plate vigorously to get all wash buffer out and block the rim of well on absorbent paper for a few seconds. Filling each well with water and remain 10 seconds. Repeat these steps 3 times. Blot dry the plate by inverting the plate onto absorbent tissue, and striking a hard surface several times.
  • Drip procedure. Mix the bottle gently before use. Violent surge may cause too much foam. Invert the bottle and squeeze one or two drop on absorbent tissue to make sure there is no foam. Take the bottle upright the well and make sure the drop does not touch the rim of wells.
  • Read procedure. Using the blank well to correct the zero point of reader if single wavelength reader is used. If double wavelength readers with 450nm and 630nm are used, there is no need to correct the zero point.
  • Storage. The whole kit should be stored at 2~8℃ for one year. Microplate should be taken to room temperature before opened. This is very important because absorbed atmospheric moisture by cold plates significantly reduces their shelf life. After removing the required number of strips, the plate should be put in the plastic resealable bag with

 

desiccants to minimize exposure to damp air.

  • Control serum is prepared with human serum, which is tested negative of HBV, HCV and HIV. But it should still be considered as capable of transmitting viral diseases.

PRECAUTION FOR USERS

1. Handling should preclude any pipetting by mouth. Use only pipettes with disposable tips for each specimen.

2.Do not mix materials from different master lots. Do not use kit components beyond the expiration date.

3.All materials should be brought to room temperature before use.

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Exporter,Trading Company,Seller

  • Ecer Certification:

    Verified Supplier

Biovantion Inc is independent from international department of Bioneovan Co., Ltd., which established in 2 0 0 5, is an in vitro diagnostic reagents manufacturer engaged in the research, development, production, and focus on clinical testing for infectious diseases, such as Hepatitis virus, Noro vir... Biovantion Inc is independent from international department of Bioneovan Co., Ltd., which established in 2 0 0 5, is an in vitro diagnostic reagents manufacturer engaged in the research, development, production, and focus on clinical testing for infectious diseases, such as Hepatitis virus, Noro vir...

+ Read More

Get in touch with us

  • Reach Us
  • Biovantion Inc.
  • Room230/232, Building 1, No.538 YongfengTun, Haidian District, Beijing
  • https://www.biovantion.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement