{"title":"Anti-Infective Irradiated Biological Dressing for Large-Area Wounds","imgUrl":"https:\/\/img.chinax.com\/nimg\/b3\/1e\/c4c826a75cac330bb5cf2336f4f7-200x200-1\/anti_infective_irradiated_biological_dressing_for_large_area_wounds.jpg","attrs":{"Brand Name":"Biovantion","Certification":"ISO13485","Place of Origin":"China","Minimum Order Quantity":"10"}}
{"title":"25-Hydroxyvitamin D Total Elisa Test Kit For Laboratory Or Hospital Use","imgUrl":"https:\/\/img.chinax.com\/nimg\/49\/cb\/85ea5e53ec16ddb873797bb8d9c6-200x200-1\/25_hydroxyvitamin_d_total_elisa_test_kit_for_laboratory_or_hospital_use.jpg","attrs":{"Brand Name":"BIOVANTION","Model Number":"TY0031","Certification":"ISO 13485","Place of Origin":"CHINA"}}
{"title":"80 Minutes Plasma AMH Test Kit Anti Mullerian Hormone Blood Test","imgUrl":"https:\/\/img.chinax.com\/nimg\/75\/67\/f6d07399e6b24953c2a3843cf7f6-200x200-1\/80_minutes_plasma_amh_test_kit_anti_mullerian_hormone_blood_test.jpg","attrs":{"Brand Name":"BIOVANTION","Model Number":"96T\/kit","Place of Origin":"CHINA","Minimum Order Quantity":"1 Box"}}
{"title":"Biomedical Equipment For Anesthesia Machine NewBright A6 Gas Source O2 0.28\uff5e0","imgUrl":"https:\/\/img.chinax.com\/nimg\/ef\/83\/1e41dc94dce03635e2c67b70fc74-200x200-1\/biomedical_equipment_for_anesthesia_machine_newbright_a6_gas_source_o2_0_28_ef_bd_9e0_6mpa_and_customized_support_oem.jpg","attrs":{"Brand Name":"Anesthesia Machine","Model Number":"NewBright A6","Certification":"CE certificate","Place of Origin":"China"}}
{"title":"Liquid Nitrogen Container-High Capacity Series Professional Medical Laboratory","imgUrl":"https:\/\/img.chinax.com\/nimg\/6f\/e8\/1f6fa0c4771a4f52f6a502cfe388-200x200-1\/liquid_nitrogen_container_high_capacity_series_professional_medical_laboratory_equipment.jpg","attrs":{"Brand Name":"Haier","Model Number":"Liquid Nitrogen Container-High Capacity Series","Certification":"CE,ISO9001","Place of Origin":"China"}}
{"title":"Controlled Rate Freezer Professional Medical Laboratory Equipment for Accurate","imgUrl":"https:\/\/img.chinax.com\/nimg\/58\/2b\/4b18ab7950f337778cc89039ba64-200x200-1\/controlled_rate_freezer_professional_medical_laboratory_equipment_for_accurate_and_fast_analysis.jpg","attrs":{"Brand Name":"Haier","Model Number":"Controlled Rate Freezer","Certification":"CE,ISO9001","Place of Origin":"China"}}
{"title":"Hot Plate Type Magnetic Stirrer LCD Display Real Time Display Of Heating","imgUrl":"https:\/\/img.chinax.com\/nimg\/71\/af\/af3ccb499b30626dd037b502bce6-200x200-1\/hot_plate_type_magnetic_stirrer_lcd_display_real_time_display_of_heating.jpg","attrs":{"Brand Name":"HUXI","Model Number":"HMS-205","Certification":"ISO9001,CE","Place of Origin":"China"}}
Thoroughly debride the wound, achieve adequate hemostasis, ensure a flat wound base, and irrigate the wound surface.
02 | Thawing
After the dressing is softened by thawing, remove it from the package for immediate use.
03 | Application
Apply the dermal (medicated) side firmly and closely to the wound surface, avoiding wrinkles.
04 | Trimming
Trim off any excess material as needed to fit the wound.
05 | Bandaging & Securing
Apply pressure bandaging with sterile secondary dressings. Recommended protocol: Vaseline gauze + multiple layers of mesh gauze + elastic bandage for compression.
Category
Guideline
Strict Aseptic Handling
Remove the packaged irradiated biological dressing from the freezer. Thaw and soften it at 35°C, then take the skin graft out of the package under sterile conditions for direct use. Do not wash the dressing, and do not apply the folded inner surface directly to the wound.
Usage Duration
The total continuous use of the product must not exceed 30 days.
Temporary Covering Material
This product is not an implantable material and is intended only for temporary coverage of wounds.
Allergy History
Use with caution in patients allergic to sulfadiazine zinc, or follow medical advice.
Transportation & Storage
Transport via general vehicles. Store frozen at -18°C.
Typically, the irradiated biological dressing does not need replacement; the outer secondary dressing is usually changed 1–2 times until healing. Ensure secure fixation at joint sites to prevent movement.
Deep Partial-Thickness (Deep II°) or Mixed-Depth Burn Wounds
Perform the first dressing change after 3 days. Assess adherence of the irradiated biological dressing to the wound. If adherence is good, re-bandage until healing. If there is excessive exudate with local dissolution of the dressing, replace the irradiated biological dressing in the affected area as needed.
Microskin Graft Wounds
The dressing effectively protects the wound, prevents infection, and promotes autologous skin graft survival and expansion without occupying space. The irradiated biological dressing will dry and slough off naturally during healing.
Donor Site Wounds
Cover the donor site with the irradiated biological dressing until healing. The outer secondary dressing may be changed 1–2 times during this period. The irradiated biological dressing will dry and slough off naturally.
Chronic Wounds
Perform the first dressing change 24–28 hours post-application. Subsequent dressing change intervals may be extended appropriately based on wound condition. Small-area wounds may heal spontaneously; large-area wounds are prepared for skin grafting.
Typically, the irradiated biological dressing does not need replacement; the outer secondary dressing is usually changed 1–2 times until healing. Ensure secure fixation at joint sites to prevent movement.
Deep Partial-Thickness (Deep II°) or Mixed-Depth Burn Wounds
Perform the first dressing change after 3 days. Assess adherence of the irradiated biological dressing to the wound. If adherence is good, re-bandage until healing. If there is excessive exudate with local dissolution of the dressing, replace the irradiated biological dressing in the affected area as needed.
Microskin Graft Wounds
The dressing effectively protects the wound, prevents infection, and promotes autologous skin graft survival and expansion without occupying space. The irradiated biological dressing will dry and slough off naturally during healing.
Donor Site Wounds
Cover the donor site with the irradiated biological dressing until healing. The outer secondary dressing may be changed 1–2 times during this period. The irradiated biological dressing will dry and slough off naturally.
Chronic Wounds
Perform the first dressing change 24–28 hours post-application. Subsequent dressing change intervals may be extended appropriately based on wound condition. Small-area wounds may heal spontaneously; large-area wounds are prepared for skin grafting.
Biovantion Inc is independent from international department of Bioneovan Co., Ltd., which established in 2 0 0 5, is an in vitro diagnostic reagents manufacturer engaged in the research, development, production, and focus on clinical testing for infectious diseases, such as Hepatitis virus, Noro vir... Biovantion Inc is independent from international department of Bioneovan Co., Ltd., which established in 2 0 0 5, is an in vitro diagnostic reagents manufacturer engaged in the research, development, production, and focus on clinical testing for infectious diseases, such as Hepatitis virus, Noro vir...