China factories

Chat Now Send Email
China factory - Biovantion Inc.

Biovantion Inc.

  • China,Beijing ,Beijing
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Anti-Infective Irradiated Biological Dressing for Large-Area Wounds
China Anti-Infective Irradiated Biological Dressing for Large-Area Wounds

  1. China Anti-Infective Irradiated Biological Dressing for Large-Area Wounds

Anti-Infective Irradiated Biological Dressing for Large-Area Wounds

  1. MOQ: 10
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms TT 100% PAYMENT
Supply Ability 100000
Delivery Time 7-15 days
Packaging Details CARTON
Brand Name Biovantion
Certification ISO13485
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms TT 100% PAYMENT Supply Ability 100000
Delivery Time 7-15 days Packaging Details CARTON
Brand Name Biovantion Certification ISO13485
Place of Origin China
High Light irradiated biological wound dressinganti-infective large-area wound dressingmedical-grade biological wound dressing

Irradiated Biological Dressing

 

Introduction for Use (Step-by-Step)

 

01 | Debridement

 
Thoroughly debride the wound, achieve adequate hemostasis, ensure a flat wound base, and irrigate the wound surface.
 

02 | Thawing

 
After the dressing is softened by thawing, remove it from the package for immediate use.
 

03 | Application

 
Apply the dermal (medicated) side firmly and closely to the wound surface, avoiding wrinkles.
 

04 | Trimming

 
Trim off any excess material as needed to fit the wound.
 

05 | Bandaging & Securing

 
Apply pressure bandaging with sterile secondary dressings. Recommended protocol: Vaseline gauze + multiple layers of mesh gauze + elastic bandage for compression.
Category Guideline
Strict Aseptic Handling Remove the packaged irradiated biological dressing from the freezer. Thaw and soften it at 35°C, then take the skin graft out of the package under sterile conditions for direct use. Do not wash the dressing, and do not apply the folded inner surface directly to the wound.
Usage Duration The total continuous use of the product must not exceed 30 days.
Temporary Covering Material This product is not an implantable material and is intended only for temporary coverage of wounds.
Allergy History Use with caution in patients allergic to sulfadiazine zinc, or follow medical advice.
Transportation & Storage Transport via general vehicles. Store frozen at -18°C.

 

Wound Type Recommended Management Protocol
Superficial Partial-Thickness (Superficial II°) Burn Wounds Typically, the irradiated biological dressing does not need replacement; the outer secondary dressing is usually changed 1–2 times until healing. Ensure secure fixation at joint sites to prevent movement.
Deep Partial-Thickness (Deep II°) or Mixed-Depth Burn Wounds Perform the first dressing change after 3 days. Assess adherence of the irradiated biological dressing to the wound. If adherence is good, re-bandage until healing. If there is excessive exudate with local dissolution of the dressing, replace the irradiated biological dressing in the affected area as needed.
Microskin Graft Wounds The dressing effectively protects the wound, prevents infection, and promotes autologous skin graft survival and expansion without occupying space. The irradiated biological dressing will dry and slough off naturally during healing.
Donor Site Wounds Cover the donor site with the irradiated biological dressing until healing. The outer secondary dressing may be changed 1–2 times during this period. The irradiated biological dressing will dry and slough off naturally.
Chronic Wounds Perform the first dressing change 24–28 hours post-application. Subsequent dressing change intervals may be extended appropriately based on wound condition. Small-area wounds may heal spontaneously; large-area wounds are prepared for skin grafting.
Wound Type Recommended Management Protocol
Superficial Partial-Thickness (Superficial II°) Burn Wounds Typically, the irradiated biological dressing does not need replacement; the outer secondary dressing is usually changed 1–2 times until healing. Ensure secure fixation at joint sites to prevent movement.
Deep Partial-Thickness (Deep II°) or Mixed-Depth Burn Wounds Perform the first dressing change after 3 days. Assess adherence of the irradiated biological dressing to the wound. If adherence is good, re-bandage until healing. If there is excessive exudate with local dissolution of the dressing, replace the irradiated biological dressing in the affected area as needed.
Microskin Graft Wounds The dressing effectively protects the wound, prevents infection, and promotes autologous skin graft survival and expansion without occupying space. The irradiated biological dressing will dry and slough off naturally during healing.
Donor Site Wounds Cover the donor site with the irradiated biological dressing until healing. The outer secondary dressing may be changed 1–2 times during this period. The irradiated biological dressing will dry and slough off naturally.
Chronic Wounds Perform the first dressing change 24–28 hours post-application. Subsequent dressing change intervals may be extended appropriately based on wound condition. Small-area wounds may heal spontaneously; large-area wounds are prepared for skin grafting.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Exporter,Trading Company,Seller

  • Ecer Certification:

    Verified Supplier

Biovantion Inc is independent from international department of Bioneovan Co., Ltd., which established in 2 0 0 5, is an in vitro diagnostic reagents manufacturer engaged in the research, development, production, and focus on clinical testing for infectious diseases, such as Hepatitis virus, Noro vir... Biovantion Inc is independent from international department of Bioneovan Co., Ltd., which established in 2 0 0 5, is an in vitro diagnostic reagents manufacturer engaged in the research, development, production, and focus on clinical testing for infectious diseases, such as Hepatitis virus, Noro vir...

+ Read More

Get in touch with us

  • Reach Us
  • Biovantion Inc.
  • Room230/232, Building 1, No.538 YongfengTun, Haidian District, Beijing
  • https://www.biovantion.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement