China factories

Chat Now Send Email
China factory - Biovantion Inc.

Biovantion Inc.

  • China,Beijing ,Beijing
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Lab research Elisa Reagents Kit for Human use IFN-γ Elisa Reagents High
China Lab research Elisa Reagents Kit for Human use IFN-γ Elisa Reagents High

  1. China Lab research Elisa Reagents Kit for Human use IFN-γ Elisa Reagents High
  2. China Lab research Elisa Reagents Kit for Human use IFN-γ Elisa Reagents High
  3. China Lab research Elisa Reagents Kit for Human use IFN-γ Elisa Reagents High
  4. China Lab research Elisa Reagents Kit for Human use IFN-γ Elisa Reagents High
  5. China Lab research Elisa Reagents Kit for Human use IFN-γ Elisa Reagents High

Lab research Elisa Reagents Kit for Human use IFN-γ Elisa Reagents High

  1. MOQ: 10 Box
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union,
Supply Ability 50000 Box/Month
Delivery Time 5-8 days
Packaging Details carton/box
Product name Human IFN-γ
Storage Temperature 2-8°C
Accuracy 99%
Method ELISA
Single Package Size 15*5*5
Material Serum
Shelf Life 24 months
Instrument classification Class III
Size 96T
Quality Control Endonuclease And Exonuclease Activity Tested
Brand Name Biovantion
Model Number 0059
Certification ISO13485
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, Supply Ability 50000 Box/Month
Delivery Time 5-8 days Packaging Details carton/box
Product name Human IFN-γ Storage Temperature 2-8°C
Accuracy 99% Method ELISA
Single Package Size 15*5*5 Material Serum
Shelf Life 24 months Instrument classification Class III
Size 96T Quality Control Endonuclease And Exonuclease Activity Tested
Brand Name Biovantion Model Number 0059
Certification ISO13485 Place of Origin China
High Light Human use Elisa Reagents Kit ,Lab research Elisa Reagents Kit ,High sensitivity Elisa Reagents Kit

Principle of the assay

The kit assay Human IFN-γ level in the sample, use Purified Human IFN-γ antibody to coat microtiter plate wells, make solid-phase antibody, then add IFN-γ to wells, Combined IFN-γ antibody which With HRP labeled, become antibody - antigen - enzyme-antibody complex, after washing Completely, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of IFN-γ in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

Features:

  • Product Name: IFN-γ
  • Storage Condition: 2-8℃ 
  • Template Dna: Not Included
  • Quality Control: Endonuclease And Exonuclease Activity Tested
 

Technical Parameters:

Attribute Value
Product Name

IFN-γ

Product Type ELISA
Size 96 T
Reaction Conditions Standard
Quality Control Endonuclease and Exonuclease Activity Tested
Package Size 96 Tests/kit
PCR Time 45min
Storage Temperature 2-8°C
Catalog Number 0059

Specimen requirements

  • extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
  • Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

Important notes

  • The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
  • washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
  • add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .
  • if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.(×n×5).
  • Closure plate membrane only limits the disposable use, to avoid cross-contamination.
  • The substrate evade the light preservation.
  • Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
  • All samples, washing buffer and each kind of reject should according to infective material process.
  • Do not mix reagents with those from other lots.
   


 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Exporter,Trading Company,Seller

  • Ecer Certification:

    Verified Supplier

Biovantion Inc is independent from international department of Bioneovan Co., Ltd., which established in 2 0 0 5, is an in vitro diagnostic reagents manufacturer engaged in the research, development, production, and focus on clinical testing for infectious diseases, such as Hepatitis virus, Noro vir... Biovantion Inc is independent from international department of Bioneovan Co., Ltd., which established in 2 0 0 5, is an in vitro diagnostic reagents manufacturer engaged in the research, development, production, and focus on clinical testing for infectious diseases, such as Hepatitis virus, Noro vir...

+ Read More

Get in touch with us

  • Reach Us
  • Biovantion Inc.
  • Room230/232, Building 1, No.538 YongfengTun, Haidian District, Beijing
  • https://www.biovantion.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement