China factories

Chat Now Send Email
China factory - Shanghai Orsin Medical Technology Co., Ltd.

Shanghai Orsin Medical Technology Co., Ltd.

  • China,Shanghai ,Shanghai
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Sodium Citrate ESR Blood Collection Tube with Screw Cap
China Sodium Citrate ESR Blood Collection Tube with Screw Cap

  1. China Sodium Citrate ESR Blood Collection Tube with Screw Cap
  2. China Sodium Citrate ESR Blood Collection Tube with Screw Cap

Sodium Citrate ESR Blood Collection Tube with Screw Cap

  1. MOQ: 100/pcs
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union
Supply Ability 20million/pcs/moth
Delivery Time 1-4 weeks
Sterilization Method Ethylene Oxide
Advanced Technology Micro-spray technology
Tube Cap Type Screw Cap
Tube Label Graduated Scale in ml
Additive Sodium Citrate
Vacuum Degree Negative Pressure
Closure Type Rubber Stopper
Sterile Non-Sterile
Platelet Activity Stability upheld
Packing 100pcs/box, 1200pcs/carton
Key Advantages Wide Compatibility
Brand Name Orsin
Model Number Gel Clot ActivatoR
Certification ISO 13485
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union Supply Ability 20million/pcs/moth
Delivery Time 1-4 weeks Sterilization Method Ethylene Oxide
Advanced Technology Micro-spray technology Tube Cap Type Screw Cap
Tube Label Graduated Scale in ml Additive Sodium Citrate
Vacuum Degree Negative Pressure Closure Type Rubber Stopper
Sterile Non-Sterile Platelet Activity Stability upheld
Packing 100pcs/box, 1200pcs/carton Key Advantages Wide Compatibility
Brand Name Orsin Model Number Gel Clot ActivatoR
Certification ISO 13485 Place of Origin China
High Light Sodium citrate ESR blood tubeESR blood collection tube with screw capVacuum blood test tube with sodium citrate

ESR Blood Collection Tubes: Professional Solution for Clinical Erythrocyte Sedimentation Rate Testing By Orsin

1 Application Scenarios: Precision Monitoring of Inflammation and Disease Activity

ESR (Erythrocyte Sedimentation Rate) blood collection tubes are critical tools in clinical laboratories for screening and monitoring inflammatory and infectious diseases. Their core function is to standardize the collection of anticoagulated venous blood samples to ensure accurate measurement of erythrocyte sedimentation velocity. These specialized vacuum tubes are primarily used with automated ESR analyzers (e.g., ESR-2040, SD-1000, BK-ESR20), enabling healthcare facilities to perform ESR testing efficiently.

In clinical diagnostics, ESR testing provides multifaceted value:

  • Inflammatory disease monitoring: Serves as a sensitive indicator for inflammation caused by rheumatic immune disorders (e.g., rheumatoid arthritis), tuberculosis, and tissue damage. ESR elevation often precedes specific clinical manifestations.

  • Diagnostic support: Functions as a non-specific auxiliary marker for infectious diseases (e.g., pneumonia, endocarditis), hematological disorders (e.g., multiple myeloma), and malignancies, providing screening clues.

  • Treatment evaluation: Dynamic ESR tracking assesses the efficacy of anti-inflammatory therapies, anti-infective treatments, or chemotherapy, guiding clinical adjustments.

2 Product Highlights: Technological Innovations Ensure Precision and Efficiency

ESR tubes overcome limitations of traditional ESR testing—such as operational complexity, biohazard risks, and result variability—through multiple technological innovations, delivering safer and more reliable sample collection for modern laboratories.

Table: Core Technical Advantages and Clinical Value of ESR Tubes

Feature Technical Advantage Clinical Value
Biosafety Vacuum-sealed design with zero blood contact; Black stopper prevents accidental opening Eliminates healthcare worker exposure; Reduces hemolysis and sample contamination
Operational Efficiency Direct compatibility with automated ESR analyzers; Pre-filled precise anticoagulant volume; Plug-and-test workflow Saves preprocessing time; Supports random access and STAT testing
Anti-Interference Capability Anticoagulant formula resistant to icterus, hemolysis, and lipemia; Optical detection compatibility Ensures reliability for pathological samples (lipemic/hemolyzed); Reduces retest rates
Result Accuracy 215mm tube length compliant with Westergren standard; Millisecond-level timing precision >95% correlation with gold-standard method (r=0.967); No mathematical correction needed
System Compatibility Supports mainstream ESR analyzers (e.g., ESR-2040, BK-ESR20); LIS barcode readability Seamless laboratory workflow integration; Reduces equipment replacement costs

Three technological breakthroughs deserve special emphasis:

  1. Vacuum-sealed system: Precisely calibrated negative pressure enables automatic blood volume aspiration, eliminating volume errors or bubble formation in open systems. Post-collection, blood remains in a closed environment, fundamentally preventing biohazard exposure.

  2. Specialized anticoagulant formulation: Sodium citratechelates calcium ions to block coagulation cascades without affecting erythrocyte aggregation. Liquid anticoagulant is pre-coated uniformly on tube walls for instant mixing.

  3. Optical compatibility: Tubes are manufactured from high-transparency glass/polymer with standardized diameter, ensuring perfect alignment with photometric scanning systems (infrared/laser detection) in automated analyzers for millisecond-level sedimentation monitoring and extended parameters (e.g., dynamic sedimentation curves, Vm values).

3 Usage Precautions: Standardized Operations Ensure Quality

3.1 Blood Collection Accuracy

  • Precise blood volume: Fill to marked fill line. Deviations >±5% cause anticoagulant imbalance, significantly altering sedimentation rates. Validate local reference ranges in high-altitude areas due to atmospheric pressure effects.

  • Venipuncture technique: Keep patient's arm downward and tube port upward to prevent blood reflux. Position needle bevel against tube wall for smooth blood flow, avoiding erythrocyte impact-induced mechanical hemolysis.

3.2 Mixing Protocol

  • Mixing method: Gently invert 5-10 times (180° rotation) immediately post-collection. Avoid vigorous shaking to prevent platelet activation or hemolysis. Inadequate mixing causes microclots that disrupt sedimentation.

3.3 Testing Timeline

  • Detection window: Complete testing within 2 hours of collection. Delays alter erythrocyte morphology and reduce sedimentation rates. If unavoidable, store vertically at 15-25°C—never refrigerate (cold accelerates sedimentation).

3.4 Collection Sequence

  • Multi-tube priority: Follow international contamination sensitivity sequence: Blood culture bottles → Coagulation tubes (blue cap) → ESR tubes (black cap) → Heparin tubes (green cap) → EDTA tubes (purple cap) → Glycolytic inhibitor tubes (gray cap). Prevents anticoagulant cross-contamination, especially EDTA interference in coagulation tests.

3.5 Storage & QC

  • Storage conditions: Unused tubes require 4-25°C避光保存, protected from freezing (causes stopper cracks/anticoagulant crystallization). Inspect anticoagulant for uniformity—discard if precipitate/floccules appear.

4 Troubleshooting: Problem Resolution

Address common technical issues promptly to ensure testing success:

  • Underfilled tubes: Caused by insufficient venous pressure or vacuum loss. Solution: Remove tube, use syringe to withdraw air via stopper to restore vacuum, or replace tube. Never inject air forcibly.

  • Blood flow interruption: Needle bevel against vein wall or venous collapse. Solution: Adjust needle angle or apply distal venous pressure. If vacuum depleted, replace tube.

  • Leakage: Compromised needle holder gasket. Solution: Pre-collection integrity check; replace components if damaged.

  • Hemolysis risk: Rapid inflow (>1ml/sec) causes impact hemolysis. Solution: Angle tube so blood flows along wall; use smaller-gauge needles (e.g., 23G) for viscous blood.

  • Incomplete mixing: Visible anticoagulant droplets post-inversion. Solution: Rotate horizontally for 10 seconds; confirm homogeneity before testing.

5 Technical Specifications

Standardized design ensures compatibility across testing environments:

  • Physical Parameters:

    • Material: High-purity glass or PET polymer (>90% light transmittance)

    • Stopper: Internationally standardized black

  • Anticoagulant System:

    • Anticoagulant: Sodium citrate

    • Format: Liquid pre-fill, 0.32ml or 0.4ml

    • Total volume: 1.28ml (with 0.32ml anticoagulant) or 1.6ml (with 0.4ml anticoagulant)

  • Performance Metrics:

    • Anticoagulant ratio: 1:4 (anticoagulant:blood)

    • Shelf life: 18 months at ambient temperature (intact packaging)

    • Centrifugation tolerance: ≥3000×g (validate polymer tube strength)

  • Compatible Systems:

    • Automated ESR analyzers: Tianhai ESR-2040 (40-position), Succeeder SD-1000 (100-sample), Biobase BK-ESR20 (20 tests/hour)

    • Traditional Westergren racks: ICSH-compliant

    • LIS/HIS integration: Barcode scanning support

As essential vessels for precision medicine, ESR tubes ensure sample integrity from patient to analyzer. Their biosafety advantages and workflow efficiency will grow increasingly vital with automated ESR adoption. Laboratories should prioritize verification of system compatibility and lot-to-lot precision when selecting products, ensuring this classic inflammatory marker continues to deliver irreplaceable value in modern healthcare.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Trading Company,Seller

  • Year Established:

    2010

  • Employee Number:

    30~60

  • Ecer Certification:

    Verified Supplier

Shanghai Orsin Medical Technology Co., Ltd. is located in No. 599, Wanhua Road, Zhelin Town, Fengxian District, Shanghai. Is China's production of one-time vacuum collection of professional companies, Shanghai Medical Device Industry Backbone Enterprises. The product takes Orsin pattern as the r... Shanghai Orsin Medical Technology Co., Ltd. is located in No. 599, Wanhua Road, Zhelin Town, Fengxian District, Shanghai. Is China's production of one-time vacuum collection of professional companies, Shanghai Medical Device Industry Backbone Enterprises. The product takes Orsin pattern as the r...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai Orsin Medical Technology Co., Ltd.
  • Building A, No.599 Wanhua Road, Zhelin Town, Fengxian Area, Shanghai, China
  • https://www.blood-tubes.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement