China factories

China factory - Henan Xianrun Blower CO.,LTD

Henan Xianrun Blower CO.,LTD

  • China,Xinxiang ,Henan
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Versatile Powerful High Pressure Centrifugal Blower For Industrial
China Versatile Powerful High Pressure Centrifugal Blower For Industrial

  1. China Versatile Powerful High Pressure Centrifugal Blower For Industrial
  2. China Versatile Powerful High Pressure Centrifugal Blower For Industrial
  3. China Versatile Powerful High Pressure Centrifugal Blower For Industrial
  4. China Versatile Powerful High Pressure Centrifugal Blower For Industrial

Versatile Powerful High Pressure Centrifugal Blower For Industrial

  1. MOQ: 1
  2. Price: 50-50000
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T
Supply Ability 10000
Delivery Time 5-45DAYS
Packaging Details WOODEN PACKING
Voltage 220/380/415/440/450v
Blade material Stainless Steel,Cast Iron,Steel Plate,Q345 (16Mn) manganese steel
Air volume 800 - 90000m3 / h
Mounting Free Standing,installed by screws
Type Centrifugal Fan,Centrifugal ventilator
After-sales service provided Engineers available to service machinery overseas,Online support
Speed 2900 r/min
Electric current type AC
Application Air Blower,cement plant
Warranty 1 Year
Material Q345/stainless/Titanium Alloy/steel,Carbon Steel /Stainless Steel,cast iron,100% Aluminum
Color Customer's Requirement,Black Silver White
Noise 72dB,56-68 dB
Product name 9-26 High Pressure Centrifugal Smoke Exhaust Ventilate Fan Blower,140mm centrifugal blower fan,Industry dust collector centrifugal exhaust fan blower,High Pressure Dust Collector Centrifugal Blower with Siemens Motor,9-19
Motor China Top Brand
Feature high efficiency,Low Noise Power Saving,easy installation,high pressure,High Performance
Pressure High Pressure,3000~16000Pa,200~3220Pa,5335-6216 Pa,4603-4447Pa
Brand Name XIANRUN BLOWER
Model Number ZR-HP SERIES
Certification CE, ISO 9001
Place of Origin XINXIANG

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T Supply Ability 10000
Delivery Time 5-45DAYS Packaging Details WOODEN PACKING
Voltage 220/380/415/440/450v Blade material Stainless Steel,Cast Iron,Steel Plate,Q345 (16Mn) manganese steel
Air volume 800 - 90000m3 / h Mounting Free Standing,installed by screws
Type Centrifugal Fan,Centrifugal ventilator After-sales service provided Engineers available to service machinery overseas,Online support
Speed 2900 r/min Electric current type AC
Application Air Blower,cement plant Warranty 1 Year
Material Q345/stainless/Titanium Alloy/steel,Carbon Steel /Stainless Steel,cast iron,100% Aluminum Color Customer's Requirement,Black Silver White
Noise 72dB,56-68 dB Product name 9-26 High Pressure Centrifugal Smoke Exhaust Ventilate Fan Blower,140mm centrifugal blower fan,Industry dust collector centrifugal exhaust fan blower,High Pressure Dust Collector Centrifugal Blower with Siemens Motor,9-19
Motor China Top Brand Feature high efficiency,Low Noise Power Saving,easy installation,high pressure,High Performance
Pressure High Pressure,3000~16000Pa,200~3220Pa,5335-6216 Pa,4603-4447Pa Brand Name XIANRUN BLOWER
Model Number ZR-HP SERIES Certification CE, ISO 9001
Place of Origin XINXIANG
High Light Versatile High Pressure Centrifugal BlowerPowerful High Pressure Centrifugal BlowerIndustrial High Pressure Centrifugal Blower

Centrifugal Fans industrial hot air blower high speed blower high pressure centrifugal blower industrial hot air blower

 

Composition and structure of centrifugal fans
1. Composition of the fan

 

The fan adopts single suction D type transmission structure, and the fan is connected with the motor by the coupling. The fan body is mainly composed of casing, air inlet, rotor group (impeller and spindle), bearing box, coupling and other parts.

 

In addition to the fan body, according to the needs of users, can also be equipped with a variety of external supporting, common: motor, regulating door, overall support, electric actuator, muffler and so on.

 

2. Introduction to the structure of the fan

 

The fan can be made into two types: from one end of the motor, such as the impeller rotates clockwise, called the clockwise cyclone, which is expressed as "clockwise"; Rotation in a counterclockwise direction is called an upwind machine, denoted by "inverse".

 

The outlet position of the fan is expressed by the outlet Angle of the casing: "forward" and "reverse" can be made into 0°, 45°, 90°, 135°, 180°, 225° a total of six angles. Other special angles can also be made according to the user's requirements.


Repair and maintenance of the fan
Correct maintenance is an important guarantee for the safe and reliable operation of the fan and the improvement of the service life of the fan. Therefore, when using the fan, it must be paid enough attention.

 

1. Repair and maintenance of impeller

 

At the beginning of the impeller operation and all regular inspections, as long as there is a chance, it is necessary to check whether the impeller has cracks, wear, dust and other defects.

 

As long as possible, it is necessary to keep the impeller clean, and regularly brush the above dust and rust with wire brush, because with the extension of the running time, these dust can not be uniformly attached to the impeller, causing the impeller balance damage, and even cause the rotor vibration.

 

As long as the impeller is repaired, it needs to be balanced again. If available, balance can be performed in the field using a portable test balance instrument. All fastening bolts must be checked for tightness before balancing. Because the impeller has been operating in an unbalanced state for some time, these bolts may have become loose.

 

2. Maintenance of casing and intake chamber

 

In addition to regular inspection of the casing and intake room, whether there is serious wear and tear, remove serious dust accumulation, these parts can not carry out other special maintenance.

 

Regularly check whether all fastening bolts are fastened. For the fan with the fastening bolt part, press the butterfly spring on the bottom foot to the installation height specified in the drawing.

 

3. Maintenance of bearing department

 

Check the bearing lubricating oil supply often. If there is oil leakage in the box, you can tighten the bolt of the end cover a little. If this is not enough, you may have to change to a new sealing packing.

 

4. Maintenance of other supporting equipment

 

The maintenance of all the supporting equipment including motors, electric actuators, instruments, meters, etc., can be found in the respective operating instructions. These instructions are provided by the supporting manufacturers, and the manufacturer will provide these instructions to the users in random boxes.

 

5. Maintenance when the fan is out of use

 

When the fan is stopped in use, when the ambient temperature is lower than 5℃, the residual water of the equipment and pipelines should be discharged to avoid freezing the equipment and pipelines.

 

6. Maintenance work when the fan is parked and stored for a long time

 

(1) The surface of bearings and other main parts is coated with anti-rust oil to avoid corrosion.

(2) Every half month or so, the fan rotor should be manually moved to rotate the rotor for half a circle (180°), and the shaft end should be marked before moving, so that the original top point is located at the bottom after moving the rotor.

 

 

 

  

Key Features 

  • Impeller diameter: 80~3500 mm 
  • Speed of mainshaft: 760~2900 rpm
  • Pressure range: 9000~25425 Pa
  • Flow range: 3297~43305 m3/h
  • Air Temperature: 20~1000 Celsius degree
  • Material: Cast Iron, Carbon Steel, Stainless Steel.

  • Efficiency: 70%-90%

Applications

  • Cement
  • Industrial boiler
  • Power generation
  • Chemical processing
  • Combustion-support
  • Cooling systems
  • Corrosive gas
  • Dryer
  • Dust collection
  • Forced draft 
  • Fume exhaust
  • General ventilation
  • Incineration
  • Induced draft

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Seller

  • Year Established:

    1995

  • Total Annual:

    100-10000000

  • Employee Number:

    50~200

  • Ecer Certification:

    Verified Supplier

ZR Blower-Premier Centrifugal Fan Manufacturer   Factory Overview. Zhirong Blower Co., Ltd., which was founded in 1985 and used to be a state - owned blower manufacturing plant affiliated to China Ministry of Machinery Industry in the past, is responsible for designing and manufacturin... ZR Blower-Premier Centrifugal Fan Manufacturer   Factory Overview. Zhirong Blower Co., Ltd., which was founded in 1985 and used to be a state - owned blower manufacturing plant affiliated to China Ministry of Machinery Industry in the past, is responsible for designing and manufacturin...

+ Read More

Get in touch with us

  • Reach Us
  • Henan Xianrun Blower CO.,LTD
  • LiMing Edifice,Xinxiang City,Henan Province,China
  • https://www.blowercentrifugalfan.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement