SGS Anti Corrosion Steam Pendant Superheater High Thermal Efficiency

  1. MOQ: 1Set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union
Supply Ability 1500 Tons / Month
Delivery Time 30 Days
Packaging Details Seaworthy Packing
Fuel Coal
Feature Energy saving
Range of Applications Power Plant
Keywords Superheater Coils
Surface Treatment Anti Corrosion
Brand Name HD Boiler
Model Number Superheater Coils
Certification ISO, ASME
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union Supply Ability 1500 Tons / Month
Delivery Time 30 Days Packaging Details Seaworthy Packing
Fuel Coal Feature Energy saving
Range of Applications Power Plant Keywords Superheater Coils
Surface Treatment Anti Corrosion Brand Name HD Boiler
Model Number Superheater Coils Certification ISO, ASME
Place of Origin China
High Light SGS steam superheaterAnti Corrosion steam superheaterAnti Corrosion pendant superheater

 

Power Plant Boiler Superheater Tube Coils Hot Selling Boiler Spare Parts

 

 

 

 

Superheater&Reheater, Custom Component For Boiler Superheater Coil

 

The function of Super heater in the thermal power plant is to remove the last traces of moisture from the saturated steam coming out of boiler and to increase its temperature above saturation temperature as per requirement at inlet of steam turbine.

 

Super heater types:
1. Radiant super heater: it is the earliest type of super heater and it is located above or behind banks of water tubes to protection them from direct flam or fire.
Parameters that increases the convection

a. Increasing the fuel-and air flow (combustion gas flow)
b. Increasing the mass flow rate of the steam

Radiation is mainly dependent on the flam temperature. as the steam flow rate increases the exit temperature become lower.
Radiant super heater
They are placed exposed to the heat source whcih requires the improvement of metal temperatures.

Radiant and convetive super heaters and reheaters are used for high temperature steam.
The accessory of high temperature radiant steam super heater in boiler

It is made up of snake-like tubes (carbon steel, alloy steel or heat-resistant steel, etc.) and collection boxes and other supporting material. Tubes generally have φ32, φ38, φ42 or other types of specifications, according to user's needs separately.

Reheaters
They are the sane as the super heaters but as their exit temperature is a little bit less than super heaters and their pressure is 20% -25% less than the super heater, they can stand less quality material alloys.

Application:
Steam super heater is consisted of dense tube coils and is placed in the flue under the tempearture 450ºC-1000ºC.
For power plant boiler capacity over 10Mpa, platen and coiled superheater are usually adopted.

 

Details

 

1 Material composition Carbon steel, alloy steel or heat-resistant steel, collection boxes and other supporting material. Tubes are customized types of specifications.
2 Design pattern Vertical or horizontal layout.
3 Advantages Beautiful appearance, size, accuracy, first-class bending and welding technology, first-class detection equipment.

 

Principle


Principle of superheater is similar to steam generating tubes of boiler.

The hot gases at high temperature sweep over superheater tubes and raise the temperature of steam which magnitude depends upon exit gas temperature leaving the superheater and gas velocity.

use for heating saturated steam, steam temperature could be up to 900 degree C.

Superheater Capacity Upgrades to Increase Power Generation

 

 

Send us required technical data, such as steam capacity, presure, required temperature etc. We will design accordingly.

 

 

HD Boiler offers a best in class facility

 

For over 30years, Hua Dong Boiler has been consistently innovating and improving our boiler superheaters and reheaters.The improvements in bending,welding and design ensure our products meet both Euorpean and American standards, ensuring a relabile performance.

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    1985

  • Total Annual:

    100,000,000-120,000,000

  • Employee Number:

    1000~1100

  • Ecer Certification:

    Verified Supplier

Hua Dong Boiler Co., Ltd. is a high-tech enterprise specialized in manufacturing boilers. Established in early 1985s, has two manufacturing bases, this company covers 400,000㎡ with fixed assets amounting to USD 110,000,000. There are 1100 employees including 150 technicians and 600 coded welders. ... Hua Dong Boiler Co., Ltd. is a high-tech enterprise specialized in manufacturing boilers. Established in early 1985s, has two manufacturing bases, this company covers 400,000㎡ with fixed assets amounting to USD 110,000,000. There are 1100 employees including 150 technicians and 600 coded welders. ...

+ Read More

Get in touch with us

  • Reach Us
  • Zhangjiagang HuaDong Boiler Co., Ltd.
  • Address: N0.1, Dongli Road, Donglai, Zhangjiagang City, Jiangsu Province, China
  • https://www.boilerfabrication.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement