| Payment Terms | L/C |
| Supply Ability | 30sets/month |
| Delivery Time | 30 work days |
| Packaging Details | Wooden case packing |
| Burn-in cabinet size(mm) | L2400*W1200*H1600 |
| Rated working voltage | 460Vac |
| Rated insulation voltage | 690Vac |
| Brand Name | CPET |
| Model Number | CP-CEF02 |
| Place of Origin | China |
View Detail Information
Explore similar products
OBC Aging Test Chamber with 7KW and 11KW Capacity for Cost Recovery in 8-12
Burn-In Test System For Household Photovoltaic Half-bridge full-bridge inverter
Burn-In Test facility For Small String Inverters Converter reflux transformer
Burn-In Test System For Microinverters DC to AC transformer test facility
Product Specification
| Payment Terms | L/C | Supply Ability | 30sets/month |
| Delivery Time | 30 work days | Packaging Details | Wooden case packing |
| Burn-in cabinet size(mm) | L2400*W1200*H1600 | Rated working voltage | 460Vac |
| Rated insulation voltage | 690Vac | Brand Name | CPET |
| Model Number | CP-CEF02 | Place of Origin | China |
| High Light | fan drive module aging test chamber ,fan drive module new energy solutions ,ec fan drive module aging test chamber | ||
Charger Aging Cabinet Constant Temperature Power Adapter Aging Check Rack
| Skills requirement | Burn-in cabinet size(mm) | L2400*W1200*H1600 |
| Rated working voltage | 460Vac | |
| Rated insulation voltage | 690Vac | |
| Rated frequency | 50Hz | |
| Rated working current | 8.3A | |
| Power frequency withstand voltage for 1 minute | 2500Vac | |
| AC input specifications | 460Vac/8.3A | |
| AC output specifications | 364Vac/8.35Amax | |
| Temperature rise | Complies with the provisions of IEC 947-1 on temperature rise, and the tempera ture rise value does not exceed thecorresponding standard requirements of the | |
| Master switch | 4way 100A | |
| Input switch | 24way 16A | |
| Output switch | 24way 16A | |
| IP rating | IP20 | |
| Noise | <70dB (measured at a distance of 1m from the device) | |
| Structural requirements | Dimension(mm) | 2400(W)*1200(D)*1600(H) |
| Burn-in slot layout requirements | The bottom of the cabinet with 3 layers and 8 Burn-in slots on each floor needs to be reserved for 40CM installation inductance | |
| Docking method | Connector supports 600VAC, 16A hard connection | |
| Cabinet door | Double door | |
| Maintenance method | Before and after maintenance |
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
10000000-15000000
Employee Number:
400~450
Ecer Certification:
Verified Supplier
CPET focuses on the research and development, manufacturing, sales and service of power electronic products such as power aging test, battery energy storage test, automatic aging test equipment, and intelligent monitoring software. Widely used in network communication, LED driven lighting, industria... CPET focuses on the research and development, manufacturing, sales and service of power electronic products such as power aging test, battery energy storage test, automatic aging test equipment, and intelligent monitoring software. Widely used in network communication, LED driven lighting, industria...
Get in touch with us
Leave a Message, we will call you back quickly!