China factories

Chat Now Send Email
China factory - JinHong Wire And Cable Group

JinHong Wire And Cable Group

  • China,Hefei ,Anhui
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China RVVP1 Spiral Wound Shielded Flexible Control Cable | Cost-Effective EMI
China RVVP1 Spiral Wound Shielded Flexible Control Cable | Cost-Effective EMI

  1. China RVVP1 Spiral Wound Shielded Flexible Control Cable | Cost-Effective EMI
  2. China RVVP1 Spiral Wound Shielded Flexible Control Cable | Cost-Effective EMI
  3. China RVVP1 Spiral Wound Shielded Flexible Control Cable | Cost-Effective EMI
  4. China RVVP1 Spiral Wound Shielded Flexible Control Cable | Cost-Effective EMI
  5. China RVVP1 Spiral Wound Shielded Flexible Control Cable | Cost-Effective EMI

RVVP1 Spiral Wound Shielded Flexible Control Cable | Cost-Effective EMI

  1. MOQ: 1000m
  2. Price: 15-35USD/m
  3. Get Latest Price
Payment Terms T/T
Delivery Time 10-15Day
Model Number RVVP1
Brand Name JinHong
Certification CE、ROHS
Place of Origin Anhui

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Delivery Time 10-15Day
Model Number RVVP1 Brand Name JinHong
Certification CE、ROHS Place of Origin Anhui
High Light RVVP1 shielded control cableflexible EMI resistant cablelow voltage signal wiring cable

Code Symbol

Full Definition

Engineering Practical Value for Design & Procurement

R

Class 5 Flexible Stranded Conductor

Multi-strand fine copper wire twisting, superior bending property, suitable for cabinet internal wiring, narrow-radius threading and frequent wiring rearrangement

V

PVC Core Insulation

Stable dielectric property, standardized wall thickness, mature production formula for conventional low-voltage signal circuits

V

PVC Outer Protective Sheath

Anti-aging, moisture-proof, dust-proof, mild acid & alkali resistance, adapts to most indoor conventional laying environments

P1

Spiral Wound Copper Shield Layer (Core Difference From Standard RVVP)

Fine copper wire continuous spiral longitudinal wrapping structure, replaces traditional copper braided mesh shielding; lower raw material consumption, moderate shielding efficiency, obvious cost advantage for general anti-interference projects

Detailed Cable Construction Analysis

Conductor: Oxygen-free annealed bare or tinned copper (Class 5 flexible stranded conductor); copper purity ≥99.95%; common cross-sections: 0.3mm², 0.5mm², 0.75mm², 1.0mm², 1.5mm², 2.5mm²

Extruded PVC Core Insulation: Uniform insulation wall thickness and stable insulation resistance; excellent crack resistance during bending and installation

Core Color Coding: Distinct insulation colors for each inner core; optional core number printing available for complex multi-core wiring and subsequent maintenance/inspection

Non-hygroscopic PP Filler: Fills gaps between insulated cores to ensure a circular cable cross-section and prevent core displacement during cabling and extrusion processes

Separation Tape: Separates the inner core assembly from the shielding layer, preventing the shield from scratching the insulation during the wrapping process

Spiral-Wound Copper Shield (Specific to RVVP1 structure): Fine copper wires wound continuously with spiral overlap; adjustable winding density; standard coverage of 75%–82%, with customizable high-density specifications (≥88%) available for environments with moderate interference

PVC Outer Sheath: Tightly extruded outer sheath; resistant to abrasion, oil, and UV-induced aging; suitable for installation in concealed conduits, surface wiring, and cable trays

2. Comprehensive Technical Specifications (Key reference for design engineers and procurement/inspection personnel)
Electrical Performance Indicators
  • Rated operating voltage: U0/U = 300/300V
  • Power-frequency withstand voltage test: 1500V; no breakdown after 5 minutes
  • DC conductor resistance at 20°C: Fully compliant with GB/T 3956 standards; strictly controlled to prevent excessive voltage drop in long-distance signal cabling
  • Insulation resistance at ambient temperature: ≥200 MΩ·km, ensuring long-term, stable insulation reliability
  • Shielding effectiveness: ≥65 dB for standard wrapped construction; ≥85 dB for high-density custom wrapped versions; capable of suppressing 50 Hz power-frequency interference and moderate-intensity high-frequency electromagnetic radiation interference
  • Inter-core capacitance: Controlled within a reasonable range to minimize phase shift and transmission deviation of analog signals
Temperature and Environmental Adaptability Parameters
  • Long-term continuous operating temperature range: -15°C to +70°C
  • Minimum ambient temperature for installation: ≥0°C (precautions required during installation to prevent sheath embrittlement/cracking)
  • Storage temperature range: -20°C to +50°C (prolonged high-temperature stacking and outdoor water immersion are strictly prohibited)
  • Flame-retardant upgrade option: ZR-RVVP1 (self-extinguishing type); meets single-cable vertical burn test requirements for fire-compartment wiring designs
Mechanical Properties and On-site Installation Parameters
  • Minimum bending radius (fixed installation): ≥8 times the cable outer diameter
  • Minimum bending radius (occasional movement/flexing): ≥12 times the cable outer diameter
  • Structural compression resistance: Suitable for installation in conduits, cable trunking, and cable trays; direct burial without protective conduit is not recommended to avoid exposure to heavy mechanical crushing forces
  • Standard core configurations: 2, 3, 4, 5, 6, 7, 8, 10, 12, 16, 20, and 24 cores; custom production for non-standard core counts is available
3. Unique Core Competitive Advantages and Differentiated Features (Compared to Standard RVVP)
3.1 Optimized Balance Between Interference Suppression and Material Costs

Standard RVVP utilizes a high-cost, dense copper braided shield designed for harsh electromagnetic interference (EMI) environments. In contrast, RVVP1 employs a helically wound copper shield structure; this meets anti-interference requirements for low-to-moderate EMI environments while effectively reducing unit material costs. For large-scale low-voltage cabling projects, this product significantly lowers total material expenditure without compromising basic signal stability, helping general contractors effectively manage the overall project budget.

3.2 Flexible Stranded Conductors Suited for Complex, Compact Cabling Environments

The product utilizes Class 5 flexible stranded copper conductors, which offer superior resistance to bending fatigue compared to solid, rigid conductors. It is ideally suited for dense cabinet wiring, routing through conduits with tight-radius bends, internal equipment wiring, and subsequent cabling adjustments, effectively minimizing the risk of circuit breaks caused by conductor fractures from repeated bending.

3.3 Robust structure, suitable for standard indoor applications, and long service life

Utilizes an aging-resistant, modified PVC formulation for both insulation and sheathing, offering resistance to indoor dust, mild moisture, and trace amounts of volatile chemical substances. Under standard installation conditions, the cable is designed for a service life of up to 25 years, thereby reducing capital expenditure for property owners and contractors regarding periodic cable replacement and system upgrades.

3.4 Diverse upgraded models to meet varied project specifications
  • ZR-RVVP1: Flame-retardant, spiral-shielded cable; suitable for wiring within fire compartments of public buildings and for low-voltage systems in commercial complexes.
  • WDZ-RVVP1: Low-smoke, zero-halogen (LSZH), flame-retardant type; suitable for underground utility tunnels, hospitals, subway stations, and densely populated enclosed buildings.
  • RVVP1-22 (Steel-tape armored): Features an additional mechanical protection layer to resist crushing and rodent damage; suitable for concealed wall installations and trench laying where there is a risk of mechanical damage.
3.4 Targeted selection for low-to-moderate interference scenarios to avoid "over-specification"

Many purchasers blindly select high-cost braided-shield RVVP cables for low-interference applications, resulting in unnecessary expense. The shielding performance of RVVP1 cables precisely meets the requirements of standard security surveillance, access control systems, and general PLC control loops, enabling rational selection and preventing the use of unnecessarily high-specification materials in engineering projects.

4. Application Scenarios (Quick Selection Guide for Engineers)
Security Surveillance and Smart Access Control System Projects

Suitable for power and signal wiring in analog cameras, infrared intrusion detectors, magnetic access control locks, perimeter alarm control panels, and residential intercom systems; effectively resolves minor signal jitter caused by parallel routing with low-power supply lines.

Light Industry Automation and General-Purpose PLC Auxiliary Control Circuits

Suitable for signal transmission between general-purpose PLC I/O modules, proximity switches, photoelectric sensors, solenoid valve feedback circuits, and field-based small-scale instrument data acquisition lines in automation equipment for packaging, food processing, and low-interference workshop environments.

Low-Voltage Integrated Cabling for Smart Residential and Commercial Buildings

Suitable for residential complexes, office buildings, and shopping malls; applications include signal lines for central air-conditioning group control, smart lighting control systems, elevator auxiliary feedback lines, building intercom backbone lines, and low-interference signal branch cables for basement equipment rooms.

Environmental Monitoring and Small-Scale Water Treatment Equipment

Suitable for connecting liquid level sensors, water quality probes, and flow transmitters within small-scale sewage pumping stations and environmental monitoring stations, as well as for signal transmission between field detection terminals and local control cabinets.

Municipal Utility Infrastructure Projects

Centralized control wiring for community public lighting; internal wiring for parking lot barrier gate control systems; feedback wiring for auxiliary road traffic signals; signal wiring for automatic remote monitoring of small pumping stations.

5. Real-world Project Application Cases (intended to boost buyer confidence and serve as a reference for bidding)
Case Study 1: Low-voltage system upgrade for a large residential complex

Project Requirements: Replace aging wiring for surveillance and access control systems across 19 residential buildings; eliminate minor electromagnetic interference caused by adjacent power distribution lines; control costs for the large-scale cabling installation.

Implementation Plan: Utilized RVVP1 2×1.0mm² and RVVP1 4×0.75mm² spiral-shielded cables; total supply volume: 243,000 meters.

Project Outcome: Following installation, video and alarm signal transmission at all monitoring points remained stable; no signal anomalies or deviations occurred during two years of operation; the project successfully passed property management acceptance inspections and the final settlement audit.

Case Study 2: Automation Assembly Line Retrofit for a Food Packaging Plant

Project Requirements: Low-power variable frequency drives (VFDs) were installed on-site; the existing unshielded cables caused slight fluctuations in sensor feedback signals, necessitating a cost-effective shielding solution.

Solution Implemented: Custom-manufactured RVVP1 6×0.5mm² control cables featuring medium-density spiral-wrapped shielding for each sensor circuit; total order volume: 57,200 meters.

Project Results: Signal fluctuations were completely eliminated, enhancing equipment operational stability; material costs were reduced by 17% compared to standard braided-shield RVVP solutions; the solution received high praise from the plant's maintenance department and automation design team.

Case Study 3: Centralized HVAC Control System for a Mid-sized Office Building

Project Requirements: Long-distance backbone cabling was required between air handling unit controllers and the central host unit; due to interference from nearby power distribution cabinets, a cost-effective shielded signal cable was needed.

Solution Implemented: RVVP1 8×1.5mm² multi-core backbone cables with spiral-wrapped shielding; total supply volume: 81,300 meters.

Project Results: The centralized control system maintained stable data communication during peak seasonal operations with no communication failures, and successfully passed third-party electrical acceptance testing upon building handover.

6. Production Standards and Global Compliance Certifications (Documentation required for tendering, inspection, and export customs clearance)
Domestic Production Standards
  • JB/T 8734.5: Electric wires and cables for electrical equipment
  • GB/T 12666: Test methods for flame-retardant and fire-resistant cables
  • GB/T 2952: Test methods for cable outer sheath properties
Export Certifications (Applicable to tendering and export clearance in African, Southeast Asian, Middle Eastern, and Latin American markets)
  • CCC (China Compulsory Certification) for standard civil-use products
  • CE certification (compliance with the EU Low Voltage Directive - LVD)
  • ISO 9001 (Quality Management System), ISO 14001 (Environmental Management System), and ISO 45001 (Occupational Health and Safety Management System) certifications
  • Factory inspection reports, raw material traceability certificates, and dimensional inspection reports provided with each order batch
  • IEC standard test reports and documentation for local market tender registration available upon customer request
7. Key Advantages of Purchasing RVVP1 Spiral-Shielded Cables

Rigorous incoming material inspection to eliminate potential quality issues later in the project

All copper materials are sourced from fully qualified, large-scale smelters; prior to production, comprehensive inspections are conducted on copper purity, PVC formulation stability, and the consistency of the spiral wrapping density. The use of recycled copper and substandard recycled plastics is strictly prohibited, effectively preventing issues such as excessive conductor resistance, sheath cracking, and insulation breakdown, thereby helping buyers avoid the risks of rework, rectification, and compensation claims associated with non-compliant cables.

Flexible customization services to meet the technical requirements of specialized projects

Customization options include conductor cross-sections, non-standard core counts, and specialized structures such as flame-retardant, low-smoke zero-halogen (LSZH), or armored designs; sheath colors, surface print content, and meter-marking formats can be tailored to client construction drawings. Small sample reels are available for preliminary performance testing, enabling design institutes and engineering firms to verify the product before formal bidding.

Factory-direct model maximizing project gross margins

Eliminates intermediary wholesale markups; offers negotiable unit prices for large-scale bulk orders while setting reasonable minimum order quantities (MOQs) to suit the purchasing needs of small-to-medium-sized contractors. Provides consolidated shipping solutions (LCL) for overseas bulk buyers to reduce overall ocean freight and logistics costs.

Full-lifecycle technical support tailored for electrical engineers

  • A professional electrical engineering team provides product selection advice, wiring scheme optimization, and technical specification drafting for tenders.
  • Supplies official technical datasheets, cable dimension drawings, and on-site wiring guides to facilitate drawing reviews and approval submissions.
  • Transparent production tracking and comprehensive pre-shipment electrical performance testing ensure on-time delivery for urgent tender projects.
  • Offers remote technical consultation to assist with installation and troubleshooting for overseas engineering projects.

Export-standard packaging and complete customs documentation

Export-grade wooden reels are used, featuring internal moisture-proof wrapping and external impact protection, making them suitable for long-distance cross-border sea and land transport. A full set of customs clearance documents—including packing lists, commercial invoices, and certificates of origin—can be provided to streamline the export declaration process for international buyers.

8. Key considerations for engineering selection and on-site installation (avoiding design flaws and construction errors)
  • Shielding layer grounding specifications: The standard installation method for RVVP1 signal cables is single-end grounding; grounding at both ends is strictly prohibited to prevent potential differences in the grounding loop from inducing additional interference signals. Specialized grounding installation guidelines can be provided upon customer request.
  • Bending radius control: The specified minimum bending radius must be strictly observed during cable pulling and conduit routing; excessive bending can loosen the helical wrap structure and compromise shielding continuity, potentially leading to operational issues such as intermittent signal transmission.
  • Separation requirements during installation: When laying cables parallel to AC power cables, safe separation distances must be maintained in accordance with local electrical codes. If routing near high-power cables, the use of separate cable trays or physical barriers is recommended to ensure effective shielding performance.
  • Storage Guidelines: Finished cable reels should be stored in a dry, well-ventilated warehouse; avoid prolonged exposure to rain and direct sunlight to delay sheath aging and extend shelf life.
  • Model Distinction: Clearly distinguish between RVVP1 (spiral-wrapped shielding) and standard RVVP (braided copper wire shielding). RVVP1 is suitable for general signal circuits with low-to-moderate interference and offers a cost advantage; however, for industrial environments with strong electromagnetic interference and high shielding performance requirements, the braided-shield RVVP type should be selected.
  • Voltage Limitations: This cable has a rated voltage of 300/300V and is intended solely for low-voltage signals and low-power control circuits; use in main power transmission lines is strictly prohibited to prevent insulation breakdown due to overload.

If your project requires a quote, technical specifications, confirmation of custom construction, or expert selection advice for RVVP1 cables, please submit your requirements via the inquiry form on our website. Be sure to specify the number of cores, conductor cross-sectional area, total order quantity, and destination country. Our professional cable engineering team will provide a tailored technical solution and a highly competitive quote within 24 working hours. We warmly welcome the opportunity to establish long-term strategic partnerships with electrical contractors, smart system integrators, electrical distributors, and architectural design firms worldwide.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2006

  • Total Annual:

    15000000000-20000000000

  • Employee Number:

    100~200

  • Ecer Certification:

    Verified Supplier

.gtr-container-k9m2p5 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; } .gtr-container-k9m2p5 .gtr-heading { ... .gtr-container-k9m2p5 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; } .gtr-container-k9m2p5 .gtr-heading { ...

+ Read More

Get in touch with us

  • Reach Us
  • JinHong Wire And Cable Group
  • Factory :No. 9, Pengfeng Road, Tongyang Industrial Park, Chaohu City, Hefei City, Anhui Province.