| Payment Terms | T/T |
| Delivery Time | 30Days |
| Model Number | WDZ-KYJYRP |
| Brand Name | JinHong |
| Place of Origin | Anhui China |
| Certification | CE、ROHS |
View Detail Information
Explore similar products
Solid Copper Core Fire Survival Fixed Wiring Cable for Emergency Load & Fire
Copper Core Fire Survival Non-sheathed Armoured Cable for Fire-rated Emergency
NH-YJV 0.6/1kV Low Voltage Fire-resistant XLPE Power Cable for High-density
Economical Aluminium Conductor Fixed Installation Distribution Cable for Civil &
Product Specification
| Payment Terms | T/T | Delivery Time | 30Days |
| Model Number | WDZ-KYJYRP | Brand Name | JinHong |
| Place of Origin | Anhui China | Certification | CE、ROHS |
The WDZ-KYJYRP is a Class B flame-retardant, Low-Smoke Zero-Halogen (LSZH), flexible control cable featuring dual-layer shielding and twisted pairs; it is specifically engineered for high-precision differential signal transmission applications requiring minimal crosstalk and robust electromagnetic interference (EMI) immunity. Unlike the WDZ-KYJRP model—which utilizes only an overall shield—this cable incorporates an individual copper tape shield for each twisted signal pair, creating a "pair-specific isolation plus overall shielding" architecture that fundamentally eliminates crosstalk between internal signal circuits. Its fully LSZH, flame-retardant construction meets mandatory fire safety standards for petrochemical plants, DCS central control rooms, hospital precision monitoring systems, and underground tunnel fire detection circuits. It fills the market gap between standard single-shielded control cables and high-end, fire-resistant, dual-shielded signal cables, striking an ideal balance among superior signal stability, fire safety performance, and overall project budget control.
Mandatory domestic standards:
Corresponding international testing standards:
| Cable Model | Shielding Structure | Signal Adaptation Type | Core Application Scenarios | Relative Material Cost |
|---|---|---|---|---|
| WDZ-KYJYRP | Individual pair shield + overall double shielding | High-precision differential signal, low crosstalk demand | DCS, temperature transmitters, tunnel fire differential detection, medical precision monitoring | Medium-High |
| WDZ-KYJRP | Only overall single copper tape shielding | Ordinary single-ended analog signal, low crosstalk requirement | Ordinary fire linkage, general PLC switch signal wiring | Medium |
| WDZ-KYJY | Unshielded LSZH soft core control cable | Low-interference on-off control circuit | Indoor low-noise auxiliary equipment control wiring | Low |
| KYJVP2 | PVC double shielded twisted pair cable | Industrial non-fire-critical instrument signal, toxic smoke when burning | Ordinary factory non-public building instrument wiring | Low |
| NH-KYJYRP | Fire-resistant double shielded twisted pair cable | Fire pump emergency differential control circuit | Core fire emergency signal trunk line of super high-rise and subway | High |
Standard voltage: 450/750V. This fully aligns with the standard operating voltages of domestic DCS (Distributed Control Systems), fire alarm differential detectors, and industrial instrumentation signal transmission systems, eliminating the need for custom voltage specifications in standard engineering projects.
Mainstream conductor cross-sections: 0.75mm², 1.0mm², and 1.5mm²; a custom 2.5mm² specification is available for long-distance tunnel signal trunk circuits.
Comprehensive range of twisted-pair unit specifications: 1 to 20 pairs (specifically including 1, 2, 3, 4, 5, 6, 8, 10, 12, 16, and 20 pairs), catering to diverse application needs ranging from single-channel instrument signal transmission to centralized integrated cabling for multiple DCS cabinets.
Conductor material standards: Utilizes 99.99% virgin T2-grade oxygen-free ultra-fine copper wire and employs a Class 5 flexible conductor compact stranding process to ensure stable, low-resistance transmission of low-current differential signals without signal attenuation.
Compared to WDZ-KYJRP cables that utilize only a single overall shield, WDZ-KYJYRP cables feature an independent copper tape shield for each pair of differential signal lines (twisted pairs) supplemented by an external overall shield, thereby creating a dual-layer isolation system. In applications such as DCS control rooms—where dozens of signal circuits are routed within the same cable tray—or petrochemical plants with dense instrumentation wiring, this independent shielding design completely eliminates crosstalk between adjacent signal pairs. This prevents issues such as analog signal drift, digital data packet loss, and measurement deviations. For differential fire detection systems in underground tunnels, stable differential signal transmission ensures the accuracy of early fire warnings and eliminates false alarms caused by internal circuit interference.
Each pair of signal lines employs a standardized fixed-pitch twisting process, effectively suppressing common-mode interference in differential signals caused by external alternating electromagnetic fields. In long-distance signal transmission scenarios (exceeding 500 meters)—such as municipal tunnels and factory workshops—this design maintains signal phase consistency, thereby resolving measurement errors in temperature transmitters and pressure sensors often associated with standard non-twisted shielded control cables.
The flexible structure, composed of stranded ultra-fine copper wires, is perfectly suited for the confined internal spaces of multi-layer, high-density DCS cabinets and wall-mounted fire alarm control panels. Electricians are not constrained by the bending radius limitations associated with rigid cables when performing terminal crimping, cable routing, and bundling; this significantly shortens the installation time for multi-pair signal trunk lines and reduces labor costs for automation system integrators.
All internal cable components completely eliminate the use of halogen-containing PVC materials. In the event of a fire in a DCS control room, underground tunnel, or basement equipment room, only a small amount of non-toxic white smoke is released; this neither obstructs visibility for rescue operations nor corrodes high-value DCS main units, precision transmitters, or fire alarm control equipment. The dual safety standards of "low smoke" and "zero halogen" have become mandatory requirements in tender specifications for public infrastructure projects, such as those in the petrochemical industry, hospitals, and municipal tunnels.
By utilizing a standardized thin-wall extrusion process for the XLPE insulation—while maintaining equivalent dielectric strength—the overall outer diameter of the WDZ-KYJYRP cable is significantly smaller than that of PVC-insulated, double-shielded twisted-pair cables with the same core count and cross-section. This allows for a higher density of signal cable pairs within limited cable tray and electrical shaft spaces, effectively resolving congestion issues associated with routing multiple instrument and fire detection trunk lines in large-scale complexes and chemical plant control rooms.
Fully automated copper tape wrapping equipment precisely controls the overlap coverage for both the individual pair shields and the overall shield. Each production batch utilizes a consistent low-smoke zero-halogen (LSZH) flame-retardant polyolefin formulation and a standardized XLPE cross-linking process. Variations in key performance metrics—such as crosstalk attenuation, smoke density, and flame retardancy—are strictly controlled within extremely tight industry tolerances across batches, thereby eliminating the risk of failing EMC spot checks or fire safety regulatory inspections due to inconsistent cable quality.
Cabling for multiple temperature and pressure transmitters in petrochemical plant control rooms; differential signal trunk lines for DCS substations in new energy battery workshops; centralized control cables for field instruments on chemical production lines
Signal transmission for fire differential detectors in urban road tunnels; twisted-pair cabling for gas leak monitoring in underground utility tunnels; smoke warning signal trunk lines for underground pedestrian passages
Interconnected cabling for vital sign monitoring equipment in Grade-III Class-A hospital wards; differential fire detection loops in large shopping mall basements; multi-circuit signal cables for fire alarm systems in airport terminals
Environmental monitoring signal cables for photovoltaic power plant control rooms; twisted-pair cabling for online water quality analyzers in wastewater treatment plants; signal transmission lines for anemometers at wind farms
Main lines for fire differential detection in super-high-rise building basements; instrument signal cabling for office building HVAC DCS substations; multi-pair control cables for smoke monitoring in residential underground garages
The project's process automation design institute specified the use of the WDZ-KYJYRP series—featuring dual-layer shielding and twisted-pair construction—to connect various field transmitters (temperature, pressure, and flow) to the central DCS host system. Previously, single-shielded WDZ-KYJRP cables had been discarded due to frequent measurement deviations caused by crosstalk between circuits, while PVC-based dual-shielded KYJVP2 cables failed to meet fire safety standards regarding Low-Smoke Zero-Halogen (LSZH) properties. Our factory provided comprehensive EMC test reports demonstrating crosstalk attenuation for the dual-shielded design, along with Class B LSZH flame-retardant certification; this ensured the project passed both fire safety and EMC inspections on the first attempt, requiring no remedial work. After two years of full-load operation, the DCS system has exhibited no measurement errors or signal loss faults across any of the instrument circuits.
The tender documents for this municipal project explicitly required that the main signal lines for the fire differential detection system utilize low-smoke, zero-halogen (LSZH), double-shielded twisted-pair control cables to withstand electromagnetic interference generated by high-power tunnel lighting and ventilation equipment. Design engineers ultimately selected the WDZ-KYJYRP model, as it was the only product capable of simultaneously meeting all electromagnetic compatibility (EMC) and fire safety performance specifications outlined in the tender. Our specialized instrumentation and electrical engineers assisted the procurement team in compiling the CCC mandatory certification, double-layer shielding attenuation test data, and IEC LSZH flame-retardant test reports. This ensured the product specifications fully aligned with the detailed technical requirements of the tender, thereby significantly boosting the contractor's overall evaluation score. Upon project completion, third-party on-site inspections confirmed that the cables successfully passed all tests regarding crosstalk and flame-retardant performance.
The hospital’s electrical and fire safety design team selected WDZ-KYJYRP multi-pair, double-shielded control cables for the patient vital-sign monitoring equipment and the differential fire detectors located in the basement. The double-shielded structure effectively isolates electromagnetic interference generated by high-frequency medical equipment—such as CT and MRI scanners—ensuring the real-time, stable transmission of differential signals for patient monitoring. The use of Low-Smoke Zero-Halogen (LSZH) flame-retardant materials throughout the installation ensures compliance with the stringent fire safety acceptance standards required for medical facilities. We provided customized, pre-cut cable lengths tailored to the specific wiring layout of each patient room, reducing cable waste by 15% and further optimizing the overall electrical material budget for the renovation project.
We offer a full range of specifications, spanning from 1-pair 0.75mm² miniature instrumentation twisted-pair cables to 20-pair 1.5mm² large-scale centralized control backbone cables. Ample stock is maintained for specifications commonly used in DCS projects for chemical plants, tunnels, and hospitals to ensure rapid delivery. Customization services—such as cut-to-length processing, laser printing of project-specific identifiers on the outer sheath, and integrated single-end grounding preparation for double-shielded cables—enable one-stop centralized procurement of LSZH double-shielded twisted-pair control cables, eliminating the need to coordinate with multiple suppliers.
We utilize only premium imported LSZH flame-retardant masterbatches, Grade-1 T2 virgin ultra-fine oxygen-free copper, and highly ductile conductive copper tapes. We strictly prohibit the use of substandard recycled halogen-free plastics, thin non-conductive copper tapes, or copper wires with excessive impurities—materials that would compromise EMC (electromagnetic compatibility) and fire safety performance. A five-stage, end-to-end inspection process is implemented: halogen and conductivity testing of incoming raw materials; real-time online monitoring of ultra-fine copper wire stranding; automatic thickness detection during XLPE insulation extrusion; closed-loop control of copper tape overlap rates for pair and overall shielding; and batch sampling of finished cables for EMC crosstalk and flame-retardant performance. This approach effectively eliminates quality defects common among smaller manufacturers, such as incomplete pair shielding coverage, excessive internal signal crosstalk, high smoke emission, and brittleness or cracking of the LSZH outer sheath.
By bypassing distributor markups, we offer tiered pricing based on purchase volume for bulk orders of WDZ-KYJYRP cables—essential for DCS systems in large petrochemical plants, municipal tunnels, and hospital ICUs. Our in-house team of senior instrumentation, automation, and electrical engineers provides complimentary design optimization services, including differential signal cross-section and twisted-pair matching, as well as cable tray isolation layouts for mixed power and signal routing. We assist clients in selecting the most cost-effective WDZ-KYJYRP specifications while fully meeting requirements for ultra-low crosstalk EMC (Electromagnetic Compatibility) and Class B fire safety standards, thereby lowering the overall investment in instrumentation and fire-safety electrical materials for the project.
Our electrical engineers possess over 15 years of experience in designing control systems for the petrochemical, tunnel, and medical instrument sectors. We provide comprehensive technical support to design institutes and automation system integrators, including: consulting on DCS differential signal loop design; providing downloadable crosstalk attenuation parameter tables for WDZ-KYJYRP double-shielded cables; preparing responses regarding EMC (Electromagnetic Compatibility) and LSZH (Low-Smoke Zero-Halogen) fire safety requirements found in tender documents; and offering guidance on compiling documentation for fire safety regulation compliance and construction acceptance. For government chemical industrial park and municipal tunnel projects, we assist in creating comparative tables—detailing double-shielded EMC performance and fire safety metrics—that meet stringent tender specifications, thereby significantly enhancing the competitiveness of contractors in the bidding process.
Multiple production lines—integrating XLPE continuous co-extrusion with automated double-layer copper tape wrapping—enable high daily output of WDZ-KYJYRP cables. Meanwhile, an extensive on-site raw material warehouse maintains ample stocks of ultra-fine copper wire, conductive copper tape, and low-smoke, zero-halogen (LSZH) flame-retardant materials. This capability ensures strict adherence to delivery schedules, even for large-volume orders required by chemical plant DCS systems or tunnel-wide fire monitoring systems, thereby eliminating the risk of work stoppages during DCS host installation or fire detector commissioning caused by supply shortages of double-shielded control cables.
All delivered WDZ-KYJYRP model low-smoke, zero-halogen (LSZH), double-shielded control cables come with a 15-year manufacturer's quality warranty covering EMC crosstalk performance (for both individual and overall shielding) and LSZH fire safety standards. A professional technical team provides remote video guidance within 24 hours to address technical challenges encountered on-site, such as DCS cabinet wiring, double-shield grounding, and tunnel installation. For long-term partners—including chemical groups, municipal tunnel contractors, and hospital construction integrators—complimentary training on standardized procedures for DCS cabinet wiring and double-shield grounding is available. Dedicated profiles are maintained for high-volume, steady clients, and raw materials are stockpiled in advance based on project schedules for DCS installation and fire monitoring systems to shorten lead times for subsequent orders.
The WDZ-KYJYRP low-smoke, zero-halogen (LSZH), flexible, twisted-pair, double-shielded control cable is a high-precision differential signal transmission solution designed specifically for petrochemical DCS (Distributed Control Systems), municipal tunnel fire-monitoring instrumentation, precision medical monitoring equipment, and multi-loop centralized fire alarm systems. This product combines three irreplaceable core advantages: it utilizes an "individual pair shielding plus overall double-layer copper tape shielding" structure, ensuring extremely low crosstalk and superior electromagnetic interference (EMI) resistance; it employs Class 5 flexible conductors, facilitating easy routing within compact DCS cabinets; and it features Class B LSZH flame-retardant properties, meeting both fire safety and environmental protection standards. It effectively resolves two critical design challenges in high-precision instrumentation projects: measurement errors caused by internal circuit crosstalk and secondary safety hazards arising from toxic smoke during fire incidents in enclosed architectural spaces.
As a professional manufacturer of WDZ-KYJYRP double-shielded twisted-pair control cables, we hold comprehensive domestic CCC certification as well as international IEC EMC and fire safety testing qualifications. We are dedicated to providing a full range of standardized low-smoke zero-halogen (LSZH) double-shielded signal control cables, complete documentation support for acceptance and certification, and professional technical consulting for DCS and fire instrumentation electrical systems. We serve global petrochemical automation integrators, municipal tunnel contractors, medical facility design institutes, and procurement teams for high-precision signal control projects. We help projects requiring moderate fire-resistance ratings—specifically those involving differential signal transmission—successfully pass EMC crosstalk spot checks and fire safety acceptance inspections, ensuring long-term, stable, interference-free, and fault-free operation of precision instrumentation and fire detection differential signal circuits throughout the entire lifecycle of the equipment and facilities.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2006
Total Annual:
15000000000-20000000000
Employee Number:
100~200
Ecer Certification:
Verified Supplier
.gtr-container-k9m2p5 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; } .gtr-container-k9m2p5 .gtr-heading { ... .gtr-container-k9m2p5 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; } .gtr-container-k9m2p5 .gtr-heading { ...
Get in touch with us
Leave a Message, we will call you back quickly!