China Electromagnetic Kitchen Fire Extinguishing System (For Grease Ducts)
China Electromagnetic Kitchen Fire Extinguishing System (For Grease Ducts)

  1. China Electromagnetic Kitchen Fire Extinguishing System (For Grease Ducts)

Electromagnetic Kitchen Fire Extinguishing System (For Grease Ducts)

  1. MOQ: 1 set
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C, D/P, T/T, Western Union, Paypal, Credit card
Supply Ability 1000 sets per month
Delivery Time 10-15 working days
Packaging Details Plywood outer box with bubble bag or paper
Maximum working pressure of the device 1Mpa
Operating temperature 0-50 ℃
Drive gas name: Nitrogen
Filling pressure of driving bottle 6Mpa
Fire extinguishing agent name Edible oil specific fire extinguishing agent
Reagent filling capacity 12L (single bottle group)/12L*2 (double bottle group)
Effective spraying time ≥ 30s
Shelf life of the drug 3 years
Temperature sensor nominal operating temperature 183 ℃
Extinguishing type Edible oil fires
Brand Name Air Giant
Model Number CMJS10-1-AG, CMJS18-2-AG
Certification CAL,CMA,CNAS,ILAC-MRA,CCC
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/P, T/T, Western Union, Paypal, Credit card Supply Ability 1000 sets per month
Delivery Time 10-15 working days Packaging Details Plywood outer box with bubble bag or paper
Maximum working pressure of the device 1Mpa Operating temperature 0-50 ℃
Drive gas name: Nitrogen Filling pressure of driving bottle 6Mpa
Fire extinguishing agent name Edible oil specific fire extinguishing agent Reagent filling capacity 12L (single bottle group)/12L*2 (double bottle group)
Effective spraying time ≥ 30s Shelf life of the drug 3 years
Temperature sensor nominal operating temperature 183 ℃ Extinguishing type Edible oil fires
Brand Name Air Giant Model Number CMJS10-1-AG, CMJS18-2-AG
Certification CAL,CMA,CNAS,ILAC-MRA,CCC Place of Origin China

  Electromagnetic Kitchen Fire Extinguishing System (For Grease Ducts)

 

Description of Kitchen Fire Suprresion System

 

Activation Method Description:

 
1. Automatic Activation Method:
Thermal Detection: When a fire occurs in the kitchen oil pot, the heat generated by the flames will cause the temperature inside the hood to rise. When the temperature reaches the preset thermal threshold of the fire suppression system (usually 183°C to 185°C), the thermal detector will automatically disconnect, triggering the fire suppression system to activate automatically.
Release of Fire Extinguishing Agent: Once the fire suppression system is activated, it will release fire extinguishing agents (such as dry powder, water-based agents, etc.) through atomizing nozzles, spraying them onto the oil pot and inside the hood. These agents will either chemically react with the burning oil or physically isolate it, forming a covering layer to cut off the air supply and extinguish the flames.
Cooling Down: After the fire suppression system sprays the extinguishing agent, it typically activates a water flow valve automatically, spraying water onto the oil pot and exhaust hood to cool them down and prevent re-ignition. The cooling water is sprayed for about two minutes before the system automatically shuts off the water.
 
2. Manual Activation Method
Fire Detection: In the early stages of a fire or if the automatic activation system fails, on-site personnel can manually activate the fire suppression system.
Operating the Manual Activation Device: Follow the instructions on the device to remove the safety pin, pull out the ring, or press the button, causing the drive valve to activate and release the fire extinguishing agent from the high-pressure cylinder.
Observing the Extinguishing Effect: After manually activating the fire suppression system, observe whether the fire source is completely extinguished and take necessary follow-up measures.
 
3. Mechanical Emergency Activation Method
Confirming Automatic and Manual Activation Failure: When both automatic and manual activation methods fail to start the device normally, the mechanical emergency activation method can be used.
Operating the Mechanical Drive Valve: Manually operate the drive valve handle to open the mechanical drive valve, releasing the fire extinguishing agent to extinguish the fire.

 

 

Components of Kitchen Fire Suprresion System

 
-- Temperature Detector (Thermal Element):Typically uses fusible alloy or glass bulb thermal sensors. When the temperature reaches the set value (usually 160°C–260°C), it automatically melts or breaks, triggering the fire suppression system.
 
-- Fire Suppressant Storage Cylinder: Stores specialized fire extinguishing agents (e.g., wet chemical fire suppressant).
 
-- Release Valve: Automatically opens when activated by the detection system, discharging the fire suppressant through the piping.
 
-- Manual Activation Device (Emergency Button): Installed in a visible location for manual fire suppression activation by personnel.
 
-- Nozzle/Spray Pipe: Positioned over high-risk fire areas such as stove tops and range hoods to ensure even distribution of the suppressant over the fire source.
 
-- Mechanical/Electric Control Unit: Receives signals from detectors, automatically shuts off gas/power (via a linked valve), and activates the suppressant release.

 
Working principle of kitchen Fire Suprresion System
                                
** Flame Detection and Activation
    Thermal Fusible Metal Cable Release Device: When the oil pot on the kitchen stove catches fire, the intense heat from the flames will cause the thermal fusible metal cable release device to heat up and detach.
    Thermal Detection System: Simultaneously, the thermal detection system will detect the flames or high temperature, triggering the release mechanism of the kitchen fire suppression system. During this step, the system pressurizes the fire extinguishing agent storage container and activates all auxiliary electric shut-off devices (such as gas shut-off valves) and alarm linkage devices.
 
** Fire Extinguishing Agent Release
    Fire Extinguishing Agent Spray: Once the release mechanism is activated, liquid fire extinguishing agents (such as foam, dry powder, or other specialized agents) are sprayed through nozzles onto the surfaces of kitchen stove equipment, as well as inside the exhaust hood, grease filter, and exhaust ducts. These specialized agents can quickly extinguish flames in the oil pot and form a covering layer to suppress the combustion of oil vapors, thereby preventing re-ignition.
    Type of Fire Extinguishing Agent: Some kitchen fire suppression systems use high-pressure gas to propel the fire extinguishing agent. In this case, a mechanical actuator pierces the high-pressure gas cylinder, releasing high-pressure gas into a pressure-reducing valve. The gas then enters the top of the fire extinguishing agent cylinder, pushing the agent through delivery pipes to the nozzles for spraying.
 
** Cooling and Flushing
    Water Spray Valve Activation: After the system's extinguishing agent is sprayed, the water spray valve on the system will automatically open after approximately 3 to 8 seconds.
    Water Flow Flushing: Water flows through the fire extinguishing agent pipes and nozzles, rapidly cooling and flushing the oil and stove equipment surfaces, ensuring the fire source is completely extinguished and preventing re-ignition.
 
** System Reset and Inspection
    Manual Reset: Some kitchen fire suppression systems require manual reset after extinguishing a fire, such as manually resetting the gas emergency shut-off valve to reopen.
    System Inspection: After each use or periodically, conduct system inspections to ensure the device is in good working condition, the fire extinguishing agent is sufficient, and all components are tightly connected without leaks.

 
 
Advantage of Kitchen Fire Suprresion System
 
**Preventing Re-ignition
**Environmentally Friendly and Safe
**Strong Applicability
**High-Efficiency Fire Suppression
 

 

Application of Kitchen Fire Suprresion System

 
Kitchen Fire Suppression Device is mainly used at the following site: hotel, restaurant kitchen, the catering center of the stadium, large/medium/small restaurant, fast food restaurant, the catering center of the airport, the kitchen of the office and hospital, large office building restaurant, the kitchen of industrial and mining enterprises, college canteen and so on.
 


 
 
Packages of Kitchen Fire Suprresion System
 
We pack products with first polyfoam and then the wooden cases. Once products are too big or customers require a pallet for products, we will make products a pallet. The following pictures are the common packing of products:
 

 
 
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Year Established:

    2022

  • Total Annual:

    5000000-10000000

  • Employee Number:

    10~50

  • Ecer Certification:

    Verified Supplier

Introduction:   Guangdong Air Giant Fire Equipment Co., Ltd. is an enterprise integrating research and development, design, manufacturing and marketing services, which is specialized in the production of HFC-227ea (pipe network type, piston flow type, cabinet type, hanging type, server-ra... Introduction:   Guangdong Air Giant Fire Equipment Co., Ltd. is an enterprise integrating research and development, design, manufacturing and marketing services, which is specialized in the production of HFC-227ea (pipe network type, piston flow type, cabinet type, hanging type, server-ra...

+ Read More

Get in touch with us

  • Reach Us
  • Guangdong Air Giant Fire Equipment Co.,Ltd.
  • Factory 101, Building 2, No. 2, Shaxing Road, Lanhe Town, Nansha District, Guangzhou,China
  • https://www.cafss-airgiant.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement