China factories

China factory - Guangdong Air Giant Fire Equipment Co.,Ltd.

Guangdong Air Giant Fire Equipment Co.,Ltd.

  • China,Guangzhou
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Kitchen Hood Fire Suppression System for Restaurants and Hotels
China Kitchen Hood Fire Suppression System for Restaurants and Hotels

  1. China Kitchen Hood Fire Suppression System for Restaurants and Hotels

Kitchen Hood Fire Suppression System for Restaurants and Hotels

  1. MOQ: 1 set
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C,D/P,T/T,Western Union,Paypal,Credit card
Supply Ability 1000 sets per month
Delivery Time 10-15 working days
Packaging Details Plywood outer box with bubble bag or paper
Maximum working pressure of the device 1Mpa
Operating temperature 0-50 ℃
Drive gas name: Nitrogen
Filling pressure of driving bottle 6Mpa
Fire extinguishing agent name Edible oil specific fire extinguishing agent
Reagent filling capacity 12L (single bottle group)/12L*2 (double bottle group)
Effective spraying time ≥ 30s
Shelf life of the drug 3 years
Temperature sensor nominal operating temperature 183 ℃
Extinguishing type Edible oil fires
Brand Name Air Giant
Model Number CMJS10-1-AG, CMJS18-2-AG
Certification CAL,CMA,CNAS,ILAC-MRA,CCC
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/P,T/T,Western Union,Paypal,Credit card Supply Ability 1000 sets per month
Delivery Time 10-15 working days Packaging Details Plywood outer box with bubble bag or paper
Maximum working pressure of the device 1Mpa Operating temperature 0-50 ℃
Drive gas name: Nitrogen Filling pressure of driving bottle 6Mpa
Fire extinguishing agent name Edible oil specific fire extinguishing agent Reagent filling capacity 12L (single bottle group)/12L*2 (double bottle group)
Effective spraying time ≥ 30s Shelf life of the drug 3 years
Temperature sensor nominal operating temperature 183 ℃ Extinguishing type Edible oil fires
Brand Name Air Giant Model Number CMJS10-1-AG, CMJS18-2-AG
Certification CAL,CMA,CNAS,ILAC-MRA,CCC Place of Origin China
High Light Hotel Kitchen Hood Fire Suppression SystemKitchen Hood Fire SuppressionRestaurant Kitchen Hood Fire Suppression System

Kitchen Hood Fire Suppression System Used In Restaurant Hotel


Description of Kitchen Fire Suprresion System


This device can achieve automatic monitoring, detection, and activation 24 hours a day, with a short spraying time of fire extinguishing agent and rapid extinguishing within 5 seconds. During fire extinguishing, the burning oil does not produce splashes. This product is started mechanically and does not require electricity. To prevent corrosion, all raw materials are made of stainless steel or copper. When installed and used, it does not occupy the kitchen area but only occupies the space and position. The installation of the number and position of nozzles is flexible and meets the requirements of the specifications. The on-site design and installation are carried out according to the number of stove fire holes. Environmentally friendly fire extinguishing agent, easy to clean, and convenient for daily cleaning. At the same time, the fire extinguishing device is installed on the surrounding walls of the protective zone, which does not occupy the ground space of the protective zone.


Components of Kitchen Fire Suprresion System


The kitchen equipment fire extinguishing device is a complete set of devices installed in high humidity and heat environments such as industrial kitchens, commercial kitchens, and civilian kitchens, including:

 

Fire extinguishing agent storage container components

Driving gas storage container components, and their driving devices

Pipelines

Nozzles

Valves

Temperature sensors

Control devices etc.



Working principle of kitchen Fire Suprresion System

                                

 ** Flame Detection and Activation

1. Thermal Fusible Metal Cable Release Device: When the oil pot on the kitchen stove catches fire, the intense heat from the flames will cause the thermal fusible metal cable release device to heat up and detach.

2. Thermal Detection System: Simultaneously, the thermal detection system will detect the flames or high temperature, triggering the release mechanism of the kitchen fire suppression system. During this step, the system pressurizes the fire extinguishing agent storage container and activates all auxiliary electric shut-off devices (such as gas shut-off valves) and alarm linkage devices.

 

** Fire Extinguishing Agent Release

1. Fire Extinguishing Agent Spray: Once the release mechanism is activated, liquid fire extinguishing agents (such as foam, dry powder, or other specialized agents) are sprayed through nozzles onto the surfaces of kitchen stove equipment, as well as inside the exhaust hood, grease filter, and exhaust ducts. These specialized agents can quickly extinguish flames in the oil pot and form a covering layer to suppress the combustion of oil vapors, thereby preventing re-ignition.

2. Type of Fire Extinguishing Agent: Some kitchen fire suppression systems use high-pressure gas to propel the fire extinguishing agent. In this case, a mechanical actuator pierces the high-pressure gas cylinder, releasing high-pressure gas into a pressure-reducing valve. The gas then enters the top of the fire extinguishing agent cylinder, pushing the agent through delivery pipes to the nozzles for spraying.

 

** Cooling and Flushing

1. Water Spray Valve Activation: After the system's extinguishing agent is sprayed, the water spray valve on the system will automatically open after approximately 3 to 8 seconds.

2. Water Flow Flushing: Water flows through the fire extinguishing agent pipes and nozzles, rapidly cooling and flushing the oil and stove equipment surfaces, ensuring the fire source is completely extinguished and preventing re-ignition.

 

** System Reset and Inspection

1. Manual Reset: Some kitchen fire suppression systems require manual reset after extinguishing a fire, such as manually resetting the gas emergency shut-off valve to reopen.

2. System Inspection: After each use or periodically, conduct system inspections to ensure the device is in good working condition, the fire extinguishing agent is sufficient, and all components are tightly connected without leaks.


Advantage of Kitchen Fire Suprresion System


**Rapid Response

**Automated Operation

**Effective Cooling and Re-ignition Prevention

**Environmentally Friendly and Safe

**Wide Applicability

**Self-Diagnostic Function



Application of Kitchen Fire Suprresion System


1. Commercial Catering Establishments: Restaurants and Canteens, Hotels and Guesthouses

2. Public Institutions and Enterprises: Schools and Hospitals, Government and Enterprise Units Food

3. Special Locations: High-Rise Buildings, Special Industries

4. Other Regulated Locations: High-Risk Fire Units, Large commercial complex



Packages of Kitchen Fire Suprresion System


We pack products with first polyfoam and then the wooden cases. Once products are too big or customers require a pallet for products, we will make products a pallet. The following pictures are the common packing of products:





Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Year Established:

    2022

  • Total Annual:

    5000000-10000000

  • Employee Number:

    10~50

  • Ecer Certification:

    Verified Supplier

Introduction:   Guangdong Air Giant Fire Equipment Co., Ltd. is an enterprise integrating research and development, design, manufacturing and marketing services, which is specialized in the production of HFC-227ea (pipe network type, piston flow type, cabinet type, hanging type, server-ra... Introduction:   Guangdong Air Giant Fire Equipment Co., Ltd. is an enterprise integrating research and development, design, manufacturing and marketing services, which is specialized in the production of HFC-227ea (pipe network type, piston flow type, cabinet type, hanging type, server-ra...

+ Read More

Get in touch with us

  • Reach Us
  • Guangdong Air Giant Fire Equipment Co.,Ltd.
  • Factory 101, Building 2, No. 2, Shaxing Road, Lanhe Town, Nansha District, Guangzhou,China
  • https://www.cafss-airgiant.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement