China factories

Chat Now Send Email
China factory - Shijiazhuang Zhengzhong Technology Co., Ltd

Shijiazhuang Zhengzhong Technology Co., Ltd

  • China,Guangzhou ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Cooling Tower Water Storage Tanks for Data Centers: Make-up, Blowdown, and Basin
China Cooling Tower Water Storage Tanks for Data Centers: Make-up, Blowdown, and Basin

  1. China Cooling Tower Water Storage Tanks for Data Centers: Make-up, Blowdown, and Basin

Cooling Tower Water Storage Tanks for Data Centers: Make-up, Blowdown, and Basin

  1. MOQ: 1set
  2. Price: $5000~$20000 one set
  3. Get Latest Price
Payment Terms L/C,T/T
Elastic same as steel sheet , around 500KN/mm
Coating color dark blue, dark green , white, and customized
Easy yo clean smooth, glossy, inert, anti-adhesion
Delivery Time 0-60 days after deposit received
Steel plates thickness 3mm - 12mm , depends on the diameter & height
PH range PH 1 - PH 14
Packaging Details PE poly-foam between each two steel plates ; wooden pallet and wooden box
serive life more than 30 years
Supply Ability 60 sets per month
Acid and alkalinity proof standard coating suits for PH3 - PH11, special coating suits for PH1 - PH14
Coating thickness 4.0.25mm - 0.4mm, two coating internal and external
Model Number J2016012315
Certification ISO 9001:2008, AWWA D103 , OSHA , BSCI
Brand Name CEC TANKS
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,T/T Elastic same as steel sheet , around 500KN/mm
Coating color dark blue, dark green , white, and customized Easy yo clean smooth, glossy, inert, anti-adhesion
Delivery Time 0-60 days after deposit received Steel plates thickness 3mm - 12mm , depends on the diameter & height
PH range PH 1 - PH 14 Packaging Details PE poly-foam between each two steel plates ; wooden pallet and wooden box
serive life more than 30 years Supply Ability 60 sets per month
Acid and alkalinity proof standard coating suits for PH3 - PH11, special coating suits for PH1 - PH14 Coating thickness 4.0.25mm - 0.4mm, two coating internal and external
Model Number J2016012315 Certification ISO 9001:2008, AWWA D103 , OSHA , BSCI
Brand Name CEC TANKS Place of Origin China
Cooling Tower Water Storage Tanks for Data Centers: Make-up, Blowdown, and Basin Design

Cooling towers reject most of a data center's heat, and they consume water through evaporation, drift, and blowdown. Behind every tower is a water storage strategy: a make-up tank to cover evaporation and outages, a basin sized for pump suction, and a blowdown path to control concentration. This article covers the storage side of the condenser loop.

Key Takeaway

For a data center cooling tower, the storage tank is mainly a make-up tank that replaces evaporated, drifted, and blown-down water and buffers against supply interruption. Size it from the tower's water balance (evaporation plus drift plus blowdown) and from your site's supply reliability, not from cooling capacity alone.

The water balance

A cooling tower loses water three ways. Evaporation scales with heat rejected; drift is tiny entrained droplets; blowdown is intentional bleed to cap dissolved solids. Make-up must equal the sum. The make-up tank then covers the lag between demand and municipal or well supply, plus outages.

  • Evaporation: scales with heat rejected.
  • Drift: small entrained loss.
  • Blowdown: controlled bleed for concentration.
  • Make-up equals the total loss.
Make-up tank sizing

Make-up volume per day is roughly the evaporation rate plus drift plus blowdown. The tank should hold enough to ride through supply interruptions and startup. A site with reliable supply may need only a few hours of make-up; a remote site needs more. The Saudi NEOM temporary water supply (2024, up to 6,000 m3 per tank) shows how make-up storage is staged for a large camp.

  • Volume from daily loss, not cooling tons.
  • Hours of buffer set by supply reliability.
  • Remote sites need larger make-up storage.
  • Staged tanks suit phased build-out.
Basin and suction design

The cold basin under the tower is the suction reservoir; its volume must avoid pump cavitation and short-cycling of the make-up valve. A separate bolted make-up tank upstream smooths supply. Coated steel resists the warm, often chemically treated condenser water.

  • Cold basin volume avoids cavitation.
  • Make-up tank upstream smooths supply.
  • Coated steel resists treated condenser water.
  • Level control ties to the make-up valve.
Element Role Design note
Cold basin Pump suction reservoir Avoid cavitation, size for drawdown
Make-up tank Buffer supply gap Hours of loss by reliability
Blowdown path Control concentration Bleed to drain or reclaim
Water quality and coating

Condenser water is warm and chemically treated, so the tank lining must resist both. GFS and FBE linings are proven in continuously wet, treated service; the Italy Sardinia warm water storage tank (2025, 1,200 m3, enamel roof) is a coated tank built for a warm water duty. Stainless suits smaller, high-purity draws.

  • Warm, treated water needs resistant lining.
  • GFS / FBE proven in wet service.
  • Stainless for small high-purity draws.
  • Roof limits debris and algae.
Our storage scope

Center Enamel supplies bolted GFS and FBE tanks for process and cooling water, shipped as panels for site erection. From a 1,200 m3 warm-water tank in Italy to staged 6,000 m3 units in Saudi Arabia, the same system serves condenser-loop storage.

  • Bolted GFS / FBE for cooling water.
  • Panels shipped for site erection.
  • Scales from 1,200 to 6,000 m3 class.
  • Roof and coating matched to duty.
Frequently Asked Questions
How big should a data center make-up tank be?

Base it on daily evaporation plus drift plus blowdown, then add hours of buffer for your supply reliability. Do not size it from cooling tons alone.

What is blowdown and why store for it?

Blowdown is the controlled bleed that caps dissolved solids. You do not store blowdown, but the make-up tank must replace it along with evaporation and drift.

Which coating for a cooling tower tank?

GFS or FBE for warm, treated condenser water; stainless for small high-purity draws. The lining must resist continuous wet, chemical service.

Can the basin be separate from the make-up tank?

Yes. The cold basin is the suction reservoir under the tower; the make-up tank is upstream and buffers supply gaps. Both matter.

Does a cooling tower tank need a roof?

A roof limits debris, sunlight, and algae. Coated, roofed bolted tanks are standard for treated cooling water.

Do you deliver staged make-up tanks for phasing?

Bolted panel tanks suit phased build-out; staged 6,000 m3-class units have been supplied for large temporary water programs.

Cooling tower water storage is a water-balance problem before it is a cooling problem. Size the make-up tank from evaporation, drift, and blowdown plus your site's supply reliability, protect the pump with a properly sized cold basin, and line the tank for warm, treated water. Bolted coated tanks make the storage practical to deliver and expand as the data center grows.

Suggested CTA: Share your tower water balance and supply reliability and we will size and line a make-up and basin storage package for your condenser loop.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    1989

  • Employee Number:

    500~600

  • Ecer Certification:

    Verified Supplier

  Shijiazhuang Zhengzhong Technology Co.,Ltd is a professional manufacturer dedicated to the design and fabrication of bolted storage tanks since 2008. Our products range includes Glass-Fused-to-Steel (GFS) tanks, fusion bonded epoxy tanks, stainless steel tanks, galvanized steel tanks a...   Shijiazhuang Zhengzhong Technology Co.,Ltd is a professional manufacturer dedicated to the design and fabrication of bolted storage tanks since 2008. Our products range includes Glass-Fused-to-Steel (GFS) tanks, fusion bonded epoxy tanks, stainless steel tanks, galvanized steel tanks a...

+ Read More

Get in touch with us

  • Reach Us
  • Shijiazhuang Zhengzhong Technology Co., Ltd
  • Fuli Commercial Center room 301#, Xingang West Rd.11#, Haizhu area, Guangzhou, Guangdong province, China.
  • https://www.cectanks.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!