| Payment Terms | L/C,T/T |
| Adhesion | 3,450N/cm |
| Elastic | Same as steel sheet ,around 500KN /mm |
| Packaging Details | PE poly-foam between each two steel plates ; wooden pallet and wooden box |
| Delivery Time | 0-60 days after deposit received |
| Capacity | 20 m3 to 18,000 m3 |
| Holiday test | >1500v |
| Service life | ≥30 years |
| Supply Ability | 60 sets per month |
| Coating thickness | 0.25mm~0.40mm & Double coating |
| Model Number | W201609013 |
| Certification | ISO 9001:2008, AWWA D103 , OSHA , BSCI |
| Brand Name | CEC TANKS |
| Place of Origin | China |
View Detail Information
Explore similar products
Glass-Fused-to-Steel Tanks for Cow Dung Anaerobic Digesters: Maximizing Biogas
The First Glass-Lined Steel Tanks Manufacturer in China
Glass Fused to Steel Potable Water Storage Tanks with Aluminum Dome Roofs:
Expandable Glass Fused to Steel Tanks Made of ART 310 Steel Plate: Advanced
Product Specification
| Payment Terms | L/C,T/T | Adhesion | 3,450N/cm |
| Elastic | Same as steel sheet ,around 500KN /mm | Packaging Details | PE poly-foam between each two steel plates ; wooden pallet and wooden box |
| Delivery Time | 0-60 days after deposit received | Capacity | 20 m3 to 18,000 m3 |
| Holiday test | >1500v | Service life | ≥30 years |
| Supply Ability | 60 sets per month | Coating thickness | 0.25mm~0.40mm & Double coating |
| Model Number | W201609013 | Certification | ISO 9001:2008, AWWA D103 , OSHA , BSCI |
| Brand Name | CEC TANKS | Place of Origin | China |
| High Light | thermal storage tanks data center cooling ,glass fused steel thermal tanks ,data center cooling tank design | ||
Once you have chosen a stratified TES system, the tank itself needs designing, not just buying. The parameters that decide performance are stratification quality, usable delta-T, diffuser design, and the height-to-diameter ratio. This article goes deep on the tank as a hydraulic device.
A thermal storage tank for data center cooling is designed around four parameters: a wide usable delta-T to maximize storage per cubic meter, a diffuser that preserves the thermocline, a height-to-diameter ratio that favors stratification, and low heat ingress through insulation and roof. Get these right and a simple tank performs like a precision device.
Storage density equals volume times usable delta-T times water properties. Widening the allowable supply-temperature swing stores more per cubic meter and shrinks the tank. The limit is your chiller and coil tolerance, so set delta-T from the cooling system, not from a rule of thumb.
The diffuser is the component that makes stratification real. It introduces water at near-tank temperature across a large area at low velocity, so layers do not mix. A poorly designed diffuser collapses the thermocline and the tank behaves like a mixed, smaller-volume vessel.
Taller, narrower tanks stratify better because the thermocline area is small relative to volume. A squat tank has more sidewall and a larger thermocline footprint. The Italy Sardinia tank (2025, 30,549 m3) and Singapore buffer tank (2020, 3,462 m3) are large coated tanks we delivered, analogous evidence of build scale, not data-center projects.
Insulation, roof, and a sealed shell limit heat gain that would erode the thermocline and waste stored cooling. The lining (GFS or FBE) also keeps the water clean so biological growth does not disturb stratification. The table lists the main parameters.
Parameter |
Effect |
Design lever |
Usable delta-T |
Storage density |
Widen from system |
Diffuser |
Stratification |
Low velocity inlet |
H/D ratio |
Stratification |
Taller preferred |
Heat ingress |
Losses |
Insulate + roof |
We have no data-center TES tank in this library. The large coated tanks cited (Italy Sardinia 30,549 m3, Singapore 3,462 m3) are analogous industrial and process deliveries, not data-center projects.
The widest allowable supply-temperature swing your chiller and coil tolerate; wider delta-T stores more per cubic meter and shrinks the tank.
It introduces water at near-layer temperature at low velocity, preserving the thermocline. A poor diffuser mixes the tank and effectively shrinks usable volume.
Generally yes for stratification: a taller, narrower tank has a smaller thermocline area relative to volume than a squat one.
Indirectly. A clean, inert lining (GFS or FBE) prevents biological growth that could disturb stratification and keeps stored water usable.
Enough to keep heat ingress from eroding the thermocline over the storage cycle; the exact level follows climate and cycle length.
Not in our project library. We cite large coated tanks at other clients as analogous capability, not data-center deliveries.
A thermal storage tank performs as a hydraulic device, not just a box of water. Maximize usable delta-T from your cooling system, design a diffuser that protects the thermocline, favor a taller height-to-diameter ratio, and limit heat ingress through insulation and roof. The lining keeps the water clean so biology does not disturb stratification. These four parameters, not the brand, decide whether a simple tank stores cooling efficiently.
Company Details
Business Type:
Manufacturer
Year Established:
1989
Employee Number:
500~600
Ecer Certification:
Verified Supplier
Shijiazhuang Zhengzhong Technology Co.,Ltd is a professional manufacturer dedicated to the design and fabrication of bolted storage tanks since 2008. Our products range includes Glass-Fused-to-Steel (GFS) tanks, fusion bonded epoxy tanks, stainless steel tanks, galvanized steel tanks a... Shijiazhuang Zhengzhong Technology Co.,Ltd is a professional manufacturer dedicated to the design and fabrication of bolted storage tanks since 2008. Our products range includes Glass-Fused-to-Steel (GFS) tanks, fusion bonded epoxy tanks, stainless steel tanks, galvanized steel tanks a...