| Payment Terms | T/T,Online order |
| Supply Ability | 100 Unit/Week |
| Delivery Time | 10-15 working days |
| Packaging Details | Neutral carton |
| Name | NOx Gas Online Monitoring System |
| Detect Gas | NO, CO, NOx, O₂, Temperature |
| Range | NO, CO, NOx: 0–500 mg/m³; O₂: 0–25% VOL |
| Detection Principle | Constant potential electrolysis method (imported sensor) |
| Brand Name | JUGE |
| Model Number | AG8000-NOx |
| Certification | IOS9001, CE |
View Detail Information
Explore similar products
Online CEMS Emission Particulate Monitoring Systems For Reactor Trace Oxygen
OEM Wireless Methane Online Gas Monitoring System Manholes Multi Parameter For
ODM High Temperature Flue Gas Sample Probe For Online Monitoring System
220V Online Gas Monitoring System Flue Gas Sampling Probe ExeblICT4Gb Grade
Product Specification
| Payment Terms | T/T,Online order | Supply Ability | 100 Unit/Week |
| Delivery Time | 10-15 working days | Packaging Details | Neutral carton |
| Name | NOx Gas Online Monitoring System | Detect Gas | NO, CO, NOx, O₂, Temperature |
| Range | NO, CO, NOx: 0–500 mg/m³; O₂: 0–25% VOL | Detection Principle | Constant potential electrolysis method (imported sensor) |
| Brand Name | JUGE | Model Number | AG8000-NOx |
| Certification | IOS9001, CE | ||
| High Light | Nitrogen Oxide Online Gas Monitoring System ,220V Online Gas Monitoring System ,220V dust monitoring system | ||
The transmitter supports multi-point upload functionality, enabling multi-point data integration, analysis, reporting, and publishing.
Fast response, with T90 as quick as 10 seconds.
Equipped with passive relay contact output and audible/visual alarm function.
Specially designed anti‑interference sensor solves the problem of sensor poisoning and damage, offering extremely high reliability.
Excellent front‑end pretreatment system that dries and filters the detected gas, ensuring more accurate gas detection, more stable operation, and effectively extending sensor life.
Features historical data storage, allowing alarm data and records to be viewed at any time.
Adopts the standard HJ212 protocol, seamlessly connecting to regional environmental protection platforms.
>>Main technical parameters
| Detect Gas | NO, CO, NOX, O2, temperature |
| Detection Principle | Constant potential electrolysis method (imported sensor) |
| Detection Method | Fixed pump suction online continuous monitoring |
| Range | NO, CO, NOx: 0–500 mg/m³; O₂: 0–25% VOL (optional; ranges not listed can be customized) |
| Resolution | 0.01, 0.1 |
| Indication error |
≤±3.0% F.S. (depends on sensor) |
| Installation | Wall-mounted, floor-standing, pole-mounted |
| Repeatability | ≤±0.5 % F.S. |
| Zero drift | ≤±5% F.S./year |
| Range drift | ≤±5% F.S./year |
| Response time | ≤15S T90 |
| Recovery time | ≤20S |
| Alarm |
Audible and visual alarm, 1 or 2 dry contact signal outputs, adjustable alarm threshold |
| Protection level | Main body IP54, detector IP66 |
| Working temperature | -20℃-+200℃ |
| Working humidity | ≤95%RH |
| Relative humidity | 10-95%RH, Built in full temperature and humidity compensation function |
| Power supply | 220V AC, 40W |
| Working Pressure | ≤200Kpa |
| Data storage | Built in storage capacity, optional storage card |
Company Details
Business Type:
Manufacturer
Year Established:
2015
Total Annual:
2000000-3000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
JUGE was established in 2015, specializing in the field of environmental online monitoring. With environmental online monitoring systems at its core, JUGE integrates R&D, production, sales, and after-sales services. It is recognized as both a National High-Tech Enterprise and a "Specialized, Ref... JUGE was established in 2015, specializing in the field of environmental online monitoring. With environmental online monitoring systems at its core, JUGE integrates R&D, production, sales, and after-sales services. It is recognized as both a National High-Tech Enterprise and a "Specialized, Ref...
Get in touch with us
Leave a Message, we will call you back quickly!