O2 Range 0-25%
Repeatability ≤2%
Payment Terms T/T,Online order
SO2 Range 0-100mg/m3 OEM
Packaging Details Neutral carton
Response Time ≤120S
Linearity Error ≤±2%F.S.
Delivery Time 10-15 working days
NO Range 0-100mg/m3 OEM
NO2 Range 0-100mg/m3 OEM
Supply Ability 100 Unit/Week
Product name CEMS for SO2 NO NO2
Model Number AG-CEMS07
Certification ISO9001 , CE
Brand Name JUGE
Place of Origin Nanjing, China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

O2 Range 0-25% Repeatability ≤2%
Payment Terms T/T,Online order SO2 Range 0-100mg/m3 OEM
Packaging Details Neutral carton Response Time ≤120S
Linearity Error ≤±2%F.S. Delivery Time 10-15 working days
NO Range 0-100mg/m3 OEM NO2 Range 0-100mg/m3 OEM
Supply Ability 100 Unit/Week Product name CEMS for SO2 NO NO2
Model Number AG-CEMS07 Certification ISO9001 , CE
Brand Name JUGE Place of Origin Nanjing, China
High Light ISO9001 CEMS SystemOnline CEMS SystemISO9001 cems emission monitoring system
Cold Drying Method SO2 NO NO2 Online Continuous Emission Monitoring CEMS System Online Gas Analyzer
Overview

This system monitors real-time concentrations of particulate matter and gaseous pollutants in flue gas emitted from stationary pollution sources such as boilers, industrial furnaces, incinerators, and similar equipment. It enables comprehensive supervision of production processes and emissions directly from the source.

The Continuous Emission Monitoring System (CEMS) consists of three fundamental components:

  • Gaseous pollutant monitoring unit (SO2, NO, NO2)
  • Flue gas parameter monitoring unit (temperature, pressure, flow rate, O2, humidity)
  • Data acquisition and processing unit

The sample gas flows through a high-temperature heated pipeline, undergoes dust removal via a two-stage filter system, and is dehumidified by a two-stage condensation system before entering the analyzer's gas chamber. The gas chamber connects to an ultraviolet differential analyzer through ultraviolet optical fibers, ensuring precise measurement of flue gas components.

Key Features
  • Secondary condensation system for rapid water removal, minimizing SO2 loss
  • Long-life UV xenon lamp with high wavelength resolution ensures low detection limits, minimal temperature drift, fast response time, and accurate measurements
  • PLC-controlled system with adjustable parameters to adapt to complex working conditions
  • Intelligent system design with traceable fault alarms for simplified maintenance and troubleshooting
  • Fully modular design enabling flexible expansion of monitoring factors
  • Flexible configuration options: Users can select between NO2-NO converter or direct NO measurement based on requirements
Technical Specifications
Parameter Category Measurement Specifications
Gaseous Pollutants SO2 (0~200) mg/m³, customizable range
NO (0~200) mg/m³, customizable range
NO2 (0~200) mg/m³, customizable range
O2 (0~25)%
Repetitiveness ≤2%
24h zero drift and range drift ≤±2% f.s.
One-week zero-point drift and range drift ≤±3% f.s.
Linear error ≤±2% f.s.
Response time ≤120s
Particulate Matter Measured range (0.5~15) m
Dust concentration range (0~10) mg/m³, customizable range
Accuracy ≤±2% f.s./24h
Flue Gas Parameters Temperature Measuring range: (0~300) ºC, customizable
Pressure Measuring range: (-10~10) kPa
Velocity of flow Measuring range: (0~40) m/s, (0~2) kPa, optional output
Humidity Measuring range: (0~40) vol%
Data Acquisition & Processing Data transmission module 8-way analog input, 1-channel RS485 communication interface
IPC 6-way RS232 communication interface, Windows operating system
Operational software Flue gas emission monitoring software monitor
Power Supply AC 220V, 50Hz, ≤7kW
System Components
CEMS Online SO2 NO NO2 Continuous Emission Monitoring System Flue Gas Analyzer - System overview and components
CEMS Online SO2 NO NO2 Continuous Emission Monitoring System Flue Gas Analyzer - Technical configuration and installation

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2015

  • Total Annual:

    2000000-3000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Reliable Solutions · Flexible Cooperation · Global Delivery · Project-Oriented Support · Long-Term Partnership Nanjing Juge Environmental Technology Co., Ltd. is a global provider of industrial environmental monitoring solutions, specializing in Continuous Emission ... Reliable Solutions · Flexible Cooperation · Global Delivery · Project-Oriented Support · Long-Term Partnership Nanjing Juge Environmental Technology Co., Ltd. is a global provider of industrial environmental monitoring solutions, specializing in Continuous Emission ...

+ Read More

Get in touch with us

  • Reach Us
  • Nanjing Juge Environmental Technology Co., Ltd.
  • Building 17, No. 99 Guangli Road, Moling Subdistrict, Jiangning District, Nanjing, Jiangsu
  • https://www.cems-system.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement