China SO2 NO NO2 AEMS Cold Drying Online Continuous Emission Monitoring CEMS System
China SO2 NO NO2 AEMS Cold Drying Online Continuous Emission Monitoring CEMS System

  1. China SO2 NO NO2 AEMS Cold Drying Online Continuous Emission Monitoring CEMS System

SO2 NO NO2 AEMS Cold Drying Online Continuous Emission Monitoring CEMS System

  1. MOQ: 1 Unit
  2. Price: USD10000-20000
  3. Get Latest Price
Repeatability ≤2%
Delivery Time 10-15 working days
Linearity Error ≤±2%F.S.
Packaging Details Neutral carton
Supply Ability 100 Unit/Week
Product name CEMS for SO2 NO NO2
NO Range 0-100mg/m3 OEM
O2 Range 0-25%
NO2 Range 0-100mg/m3 OEM
Response Time ≤120S
SO2 Range 0-100mg/m3 OEM
Payment Terms T/T,Online order
Brand Name JUGE
Place of Origin Nanjing, China
Certification ISO9001 , CE
Model Number AG-CEMS07

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Repeatability ≤2% Delivery Time 10-15 working days
Linearity Error ≤±2%F.S. Packaging Details Neutral carton
Supply Ability 100 Unit/Week Product name CEMS for SO2 NO NO2
NO Range 0-100mg/m3 OEM O2 Range 0-25%
NO2 Range 0-100mg/m3 OEM Response Time ≤120S
SO2 Range 0-100mg/m3 OEM Payment Terms T/T,Online order
Brand Name JUGE Place of Origin Nanjing, China
Certification ISO9001 , CE Model Number AG-CEMS07
High Light ISO9001 CEMS SystemOnline CEMS SystemISO9001 cems emission monitoring system

Cold Drying Method SO2 NO NO2 Online Continuous Emission Monitoring CEMS System Online Flue

Gas Analyzer

 

>>Overview

It can monitor the real-time concentration of particulate matter and gaseous pollutants in the flue gas emitted from stationary pollution sources (such as boilers, industrialfurnaces, incinerators, etc.), enabling supervision of production and emissions fromthe source.

CEMS (Continuous Emission Monitoring System) generally consists of three basic components: the gaseous pollutant monitoring unit (SO2, NO, NO2), the flue gas parameter monitoring unit (temperature, pressure, flow rate, O2, humidity), and the data acquisition and processing unit.

The sample gas passes through a high-temperature heated pipeline, undergoes dustremoval via atwo-stage filter,and is dehumidified by a two-stage condensation system before directly entering the gas chamber of the analyzer. The gas chamber ishoused within the analyzer and connected to an ultraviolet differential analyzer via ultraviolet optical fibers, achieving accurate measurement of the flue gas.


>>Feature
1) Secondary condensation for rapid water removal, reducing SO2 loss.
2) Long-life UV xenon lamp with high wavelength resolution ensures low detection limits, minimal temperature drift, fast response time, and accurate measurements.
3) PLC-controlled with adjustable parameters to adapt to complex working conditions.
4) Intelligent system design with traceable fault alarms for easy maintenance and troubleshooting.
5) Fully modular design, enabling flexible expansion of monitoring factors.
6) Flexible configuration: Users can choose between an NO2-NO converter or direct NO measurement as required.

>>Main technical parameters
Project Index
Gaseous pollutant So2 (0~200) mg/m3, the range can be customized
No (0~200) mg/m3, the range can be customized
No2 (0~200) mg/m3, the range can be customized
O2 (0~25)%
Repetitiveness ≤2%
24h zero drift and range drift ≤±2%f.s.
One-week zero-point drift and range drift ≤±3%f.s.
Linear error ≤±2%f.s.
Response time ≤120s
Particulate matter Measured range (0.5~15)m
Dust concentration range (0~10) mg/m3, the range can be customized
Accuracy ≤±2%f.s./24h
Flue gas parameters Temperature Measuring range (0~300) ºC, is customizable
Accuracy  
Pressure Measuring range (-10~10)kpa
Accuracy  
Velocity of flow Measuring range (0~40) m/s, (0~2) kpa, the output is optional
Accuracy  
Humidity Measuring range (0~40)vol%
Accuracy  
Data acquisition and processing Data transmission module 8-way analog input 
1-channel rs485 communication interface
IPC 6-way rs232 communication interface
Windows7 operating system
Operational software Flue gas emission monitoring software monitor
Power Supply Ac 220v,50hz,≤7kw

 

>>System composition
Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer
Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2015

  • Total Annual:

    2000000-3000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Reliable Solutions · Flexible Cooperation · Global Delivery · Project-Oriented Support · Long-Term Partnership Nanjing Juge Environmental Technology Co., Ltd. is a global provider of industrial environmental monitoring solutions, specializing in Continuous Emission ... Reliable Solutions · Flexible Cooperation · Global Delivery · Project-Oriented Support · Long-Term Partnership Nanjing Juge Environmental Technology Co., Ltd. is a global provider of industrial environmental monitoring solutions, specializing in Continuous Emission ...

+ Read More

Get in touch with us

  • Reach Us
  • Nanjing Juge Environmental Technology Co., Ltd.
  • Building 17, No. 99 Guangli Road, Moling Subdistrict, Jiangning District, Nanjing, Jiangsu
  • https://www.cems-system.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement