Impeller Support | SWSI (Single Width, Single Inlet), Impeller overhung |
Bearing Type | Rolling bearing |
Motor type | Three Phase AC Motor |
Color | Grey |
Impeller | Dynamic Balanced |
Noise | ≤85dB |
Lubrication | Oil bath lubrication |
Bearing cooling | Air cooling or Circulating Water cooling |
Airflow | 25000m3/h |
Humidity | ≤85%RH |
Material | Steel |
Name | Dust Collector Fan |
Power | 2.2KW |
Pressure | 3000Pa |
Size | Customized |
Speed | 1450r/min |
Temperature | -20℃-80℃ |
Type | Industrial Fan |
Voltage | 440V |
Brand Name | SIMO BLOWER |
Model Number | SIMO Blower 6-06 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Single Suction Long Lifetime Backward Material Handling Blower
16Mn Medium Pressure Wear Resistant Material Handling Blower
Alternating Current Material Handling Blower Long Life Forward
Explosion Proof Centrifugal SWSI Material Handling Blower
Product Specification
Impeller Support | SWSI (Single Width, Single Inlet), Impeller overhung | Bearing Type | Rolling bearing |
Motor type | Three Phase AC Motor | Color | Grey |
Impeller | Dynamic Balanced | Noise | ≤85dB |
Lubrication | Oil bath lubrication | Bearing cooling | Air cooling or Circulating Water cooling |
Airflow | 25000m3/h | Humidity | ≤85%RH |
Material | Steel | Name | Dust Collector Fan |
Power | 2.2KW | Pressure | 3000Pa |
Size | Customized | Speed | 1450r/min |
Temperature | -20℃-80℃ | Type | Industrial Fan |
Voltage | 440V | Brand Name | SIMO BLOWER |
Model Number | SIMO Blower 6-06 | Certification | CE |
Place of Origin | China | ||
High Light | cement kiln centrifugal induced draft fan ,medium pressure centrifugal induced draft fan ,90kw id fan |
Introduction
Cement plant dust removal fan form
1) The fan is of single suction type. Machine number №2.8~28#
2) Each fan can be made into two forms: left-hand rotation or right-hand rotation.
3) The position of the fan outlet is expressed by the same outlet angle of the casing.
4) The fan transmission mode is A, motor direct connection mode B, C mode: belt drive
D type: coupling transmission E, F type: belt transmission
Detail introduction
Structural features of dust removal fans in cement plants
Chassis: Made of steel plate, it is strong and reliable. It can be divided into integral type and semi-open type. The semi-open type is convenient for maintenance. The fans below 14# are mostly integral type, and the fans above 14# are mostly semi-open type.
Impeller: It is welded and formed by a flat rear disc, blades and front disc.
Transmission part: It consists of main shaft, bearing box, rolling bearing and pulley (or coupling).
Air inlet: It is made of steel plates welded into a tapered shape, forming a convergent streamlined overall structure. It is installed on the side and axial direction of the fan. The cross-section is curved, which allows the gas to enter the impeller smoothly with less loss.
Adjustment door: Installed in front of the air inlet, the air volume can be adjusted while the fan speed (pressure) remains unchanged.
Technical data
series | model | Rotation Speed (r/min) |
Total Pressure (Pa) |
Air Capacity (m³/h) |
Power (kW) |
6-11 | 14D | 1450 | 5435~7086 | 22889~41542 | 90~110 |
15D | 1450 | 6240~8134 | 28153~51095 | 110~160 | |
16D | 1450 | 7099~9255 | 34167~62011 | 160~220 | |
17D | 1450 | 8014~10448 | 40892~74379 | 220~280 | |
18D | 1450 | 8986~11713 | 48648~88292 | 280~400 | |
19D | 1450 | 10012~13051 | 57215~103840 | 400~500 | |
20D | 1450 | 11093~14461 | 66733~121114 | 450~630 |
Product Features
Provide factory measurement performance, vibration, and test report to prevent failure and ensure the operation of the fan in good condition.The converging and streamlined air inlet is made into a unitary structure and bolted to the inlet side of the fan.
FAQ
1,What parameters need to be provided when you design the industrial centrifugal fans?
A: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.
If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.
2,How about your company’s pre-sales service and after-sales service?
A: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.
After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.
3,Does your company have qualifications?
A: SIMO Blower has obtained ISO 9001-2008, CE, TUV certifications and so on.
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
3500000-5000000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Xinxiang SIMO Blower Co., Ltd. was founded in 2008, located in Xinxiang city, Henan province. SIMO is a professional manufacturer engaged in the research, development, production, sale and service of centrifugal fans, axial fans, blower fan parts. As the senior member of China General Machinery Indu... Xinxiang SIMO Blower Co., Ltd. was founded in 2008, located in Xinxiang city, Henan province. SIMO is a professional manufacturer engaged in the research, development, production, sale and service of centrifugal fans, axial fans, blower fan parts. As the senior member of China General Machinery Indu...
Get in touch with us
Leave a Message, we will call you back quickly!